• 1. Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin 300384, P.R.China;
  • 2. National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin 300384, P.R.China;
  • 3. Department of Orthopedic Surgery, General Hospital of Chinese People’s Liberation Army, Beijing 100853, P.R.China;
DU Chengfei, Email: ddccffb31@hotmail.com
Export PDF Favorites Scan Get Citation

Finite element method (FEM) was used to investigate the biomechanical properties of three types of surgical fixations of U-shaped sacral fractures. Based on a previously established and validated complete lumbar-pelvic model, three models of surgical fixations of U-shaped sacral fractures were established: ① S1S2 passed through screw (S1S2), ② L4–L5 pedicle screw + screw for wing of ilium (L4L5 + IS), and ③ L4–L5 pedicle screw + S1 passed through screw + screw for wing of ilium (L4L5 + S1 + IS). A 400 N force acting vertically downward, along with torque of 7.5 N·m in different directions (anterior flexion, posterior extension, axial rotation, and axial lateral bending), was exerted on the upper surface of L4. Comparisons were made on differences in separation of the fracture gap and maximum stress in sitting and standing positions among three fixation methods. This study showed that: for values of separation of the fracture gap produced by different operation groups in different positions, L4L5 + S1 + IS was far less than L4L5 + IS and S1S2. For internal fixators, the maximum stress value produced was: L4L5 + IS > L4L5 + S1 + IS > S1S2. For the intervertebral disc, the maximum stress value produced by S1S2 is much larger than that of L4L5 + S1 + IS and L4L5 + IS. In a comprehensive consideration, L4L5 + S1 + IS could be prioritized for fixation of U-shaped sacral fractures. The objective of this research is to compare the biomechanical differences of three different internal fixation methods for U-shaped sacral fractures, for the reference of clinical operation.

Citation: LI Junwei, PENG Ye, YUCHI Chenxi, DU Chengfei. Finite element analysis of fixation of U-shaped sacral fractures. Journal of Biomedical Engineering, 2019, 36(2): 223-231. doi: 10.7507/1001-5515.201808026 Copy

  • Previous Article

    Kinematics and workspace analysis of a spherical exoskeleton parallel mechanism
  • Next Article

    The in vivo thrombosis evaluation for the biodegradable polymer stent