• 1. Department of Pharmacy, Sichuan Orthopedic Hospital, Chengdu, Sichuan 610041, P. R. China;
  • 2. West China School of Pharmacy, Sichuan University, Chengdu, Sichuan 610041, P. R. China;
Export PDF Favorites Scan Get Citation

Objective To establish a method for content determination of ferulic acid in Piwang massage lotion. Methods High performance liquid chromatography was used. The analysis was carried on Diamonsil C18 (150 mm×4.6 mm, 5 μm, Dimma Science and Technology Co. Ltd.) column with mobile phase consisted of methanol-2% acetic acid (32︰68). The column temperature was 30℃. The detection wavelength was 320 nm. Results The responses of ferulic acid liner in range of 4.55-91.00 μg/mL (R2=0.999 9). The average recovery of ferulic acid was 98.78% (relative standard deviation is 2.668%). Conclusion The method is simple, rapid and good repeatability. It can be used for quality control of Piwang massage lotion

Citation: TUHe, LIANGLi, HOUShi-xiang, FENGGuang-fu. The Content Determination of Ferulic Acid in Piwang Massage Lotion by High Performance Liquid Chromatography. West China Medical Journal, 2014, 29(9): 1697-1700. doi: 10.7507/1002-0179.20140517 Copy

  • Previous Article

    Analysis of High-risk Factors for Death in Infants with Severe Pneumonia
  • Next Article

    The CT Characteristics of Pleural Lung Cancer and Misdiagnosis Analysis