• 1. Department of Nephrology, Xinle City Hospital, Xinle, Hebei 050700, P. R. China;
  • 2. Department of Nephrology, Zhejiang Hospital, Hangzhou, Zhejiang 310031, P. R. China;
  • 3. Second Department of Nephrology, the First Hospital of Hebei Medical University, Shijiazhuang, Hebei 050051, P. R. China;
XU Yuankai, Email: xyk19870309@126.com
Export PDF Favorites Scan Get Citation

Venous pressure monitoring is an important indicator for the arteriovenous fistula evaluation. Direct static venous pressure monitoring is recognized as the most accurate way of venous pressure monitoring, which is widely used in the functional monitoring, functional evaluation of arteriovenous fistula, the diagnosis of complications and the evaluation of surgical efficacy. Venous pressure monitoring has obvious advantages and disadvantages, so it is necessary to improve relevant knowledge to correctly guide clinical diagnosis and treatment. In this paper, the study of static venous pressure monitoring of arteriovenous fistula was summarized, in order to improve the understanding of the significance and clinical application of static venous pressure monitoring of arteriovenous fistula.

Citation: LI Xinhu, XU Yuankai, ZHANG Lihong. Application progress of venous pressure monitoring in arteriovenous fistula. West China Medical Journal, 2022, 37(7): 1094-1097. doi: 10.7507/1002-0179.202006098 Copy

  • Previous Article

    Clinical monitoring and risk assessment of regional citrate anticoagulation in continuous renal replacement therapy
  • Next Article

    Research progress of Bruton’s tyrosine kinase inhibitors in the treatment of Waldenström macroglobulinemia