• 1. Department of Joint Surgery, Yantai Affiliated Hospital of Binzhou Medical University, Yantai Shandong, 264100, P. R. China;
  • 2. Department of Joint Surgery, the Affiliated Hospital of Qingdao University, Qingdao Shandong, 266000, P. R. China;
TIAN Shaoqi, Email: shaoqi99@aliyun.com
Export PDF Favorites Scan Get Citation

Objective  To investigate the diagnostic efficacy of silkworm larvae plasma (SLP) colorimetry in the accurate diagnosis of periprosthetic joint infection (PJI). Methods  Ninety healthy male New Zealand white rabbits were used for knee arthroplasty with Swanson prosthesis. Then they were randomly divided into 3 groups according to different pathogenic bacteria: group A (Staphylococcus aureus group), group B (Staphylococcus epidermidis group) and group C (Escherichia coli group), with 30 rats in each group. The PJI model was prepared by knee injection with 1 mL of pathogenic bacteria of different concentrations. Samples were taken before inoculation and at 7, 14, and 21 days after inoculation, and based on the 2018 PJI Philadelphia International Consensus diagnostic criteria, the success rate of modeling among 3 groups of experimental animals was determined. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic efficiency of SLP colorimetry were calculated. Results  At 21 days after inoculation, 26, 18, and 23 rabbits in groups A, B, and C were diagnosed as infection, respectively. The success rates of modeling were 86.7%, 60.0%, and 76.7%, respectively, showing no significant difference among the 3 groups (χ2=5.724, P=0.073). The results of PJI colorimetry showed that 1 false-positive animal (specificity 75.0%) appeared in group A at 7 days, and the specificity of SLP increased to 100.0% over time (on 14 and 21 days); on 14 and 21 days, another animal appeared false-negative results (sensitivity decreased from 100.0% to 96.2%). One false-positive animal appeared in group B at 7 days (specificity 91.7%), the specificity returned to 100.0% over time; 1 and 4 false-negative animals appeared at 14 and 21 days, respectively (sensitivity 94.4% and 83.3%, respectively). In group C, two false-positive animals (specificity 71.4%) were found at 7 days, and then returned to 100.0%. The diagnostic efficiency of groups A and C was very high at 21 days (96.7% and 100.0%), even for the low virulence Staphylococcus epidermidis in group B, the diagnostic efficiency could be maintained at 90.0% (21 days), and the overall diagnostic efficiency was very good (95.6%). Conclusion  SLP colorimetry has high sensitivity, specificity, and diagnostic efficiency in the diagnosis of PJI, which is a potential diagnostic method.

Citation: ZHANG Chi, WANG Yuanhe, SUN Kang, TIAN Shaoqi. Experimental study of silkworm larvae plasma colorimetry based on immune cascade reaction in accurate diagnosis of periprosthetic joint infection. Chinese Journal of Reparative and Reconstructive Surgery, 2022, 36(2): 203-208. doi: 10.7507/1002-1892.202109046 Copy

  • Previous Article

    Effectiveness of structural bone graft in total hip arthroplasty for Hartofilakidis type developmental dysplasia of the hip
  • Next Article

    Radiographic study of relationship between medial cuneiform obliquity and simple hallux valgus