Objective To investigate the effectiveness of the perforator-based propeller flaps (PPFs) based on digital artery (DA) and dorsal metacarpal artery (DMA) in repairing hand wounds. Methods The clinical data of 45 patients with hand wounds between January 2018 and March 2023 were retrospectively analyzed. There were 27 males and 18 females with an average age of 41.2 years (range, 14-72 years). The causes of injury included twist injury in 15 cases, crush injury in 19 cases, and cut injury in 11 cases. The injured parts included 32 cases of digits, 10 cases of dorsal hand, and 3 cases of palmar hand, all of which had tendon, joint, and bone exposure. The time from injury to operation ranged from 2 to 8 hours (mean, 4.3 hours). The wound sizes after debridement ranged from 1.8 cm×1.0 cm to 5.0 cm×3.5 cm. Twenty-eight cases were repaired by the PPFs based on DA and 17 cases were repaired by the PPFs based on DMA. The flap size ranged from 2.5 cm×1.1 cm to 8.5 cm×4.0 cm. The defects of the donor sites in 14 patients were closed directly and the defects in the left 31 patients were resurfaced with free full-thickness skin graft from the proximal medial forearm.Results All the flaps survived after operation. Two cases of the PPF based on DA and 1 case of the PPF based on DMA underwent partially blisters at the distal end and healed after dressing change. The incisions in the donor site healed by first intention and the skin grafts survived. All patients were followed up 10-33 months, with a mean of 15.4 months. At last follow-up, the static two-point discrimination of the PPFs based on DA and DMA were 4-14 mm and 8-20 mm with the averages of 8.1 mm and 13.3 mm, respectively. According to the Michigan Hand Outcomes Questionnaire, 20 patients were very satisfied with the appearance of the PPF based on DA and 8 patients were satisfied; 8 patients were very satisfied with the appearance of the PPF based on DMA and 9 patients were satisfied. Based on the Vancouver Scar Scale (VSS), the appearance scores of the donor site of the PPFs based on DA and DMA were 2-7 and 4-9, with the averages of 4.2 and 6.1, respectively. Conclusion The two kinds of PPFs are reliable in blood supply and easy to harvest, which provide a good method for emergency repair of small and medium area wounds in the hand.
Citation:
WANG Hui, WANG Haifeng, QIN Haoyu, HAO Ruizheng, MA Tiepeng, LIU Ying, WANG Bin. Clinical application of perforator-based propeller flaps in repair of hand wound. Chinese Journal of Reparative and Reconstructive Surgery, 2024, 38(8): 1016-1021. doi: 10.7507/1002-1892.202404006
Copy
1. |
|
2. |
|
3. |
|
4. |
|
5. |
|
6. |
|
7. |
|
8. |
|
9. |
|
10. |
Georgescu AV, Matei IR, Bumbasirevic M, et al. Why, when and how propeller perforator flaps in reconstructive surgery. Injury, 2019, 50 Suppl 5: S3-S7.
|
11. |
|
12. |
|
13. |
|
14. |
|
15. |
|
16. |
|
17. |
|
18. |
|
19. |
|
20. |
|
21. |
|
22. |
|
23. |
|
24. |
|
25. |
|
26. |
|
27. |
|
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
- 9.
- 10. Georgescu AV, Matei IR, Bumbasirevic M, et al. Why, when and how propeller perforator flaps in reconstructive surgery. Injury, 2019, 50 Suppl 5: S3-S7.
- 11.
- 12.
- 13.
- 14.
- 15.
- 16.
- 17.
- 18.
- 19.
- 20.
- 21.
- 22.
- 23.
- 24.
- 25.
- 26.
- 27.