Objective To compare the difference of effect while using homograft pericardium patch and Gore- tex patch in staged repair of tetralogy of Fallot(TOF) to enlarge the right ventricular outflow tract (RVOT). Methods Twenty-eight patients with TOF who underwent the staged complete repair were divided into 2 groups according to the date of surgery. Gore-rex group, 13 cases, their RVOT were enlarged with Gore-tex patches. Cryopreserved homograft pericardium patch group, 15 cases, their RVOT were enlarged with cryopreserved homograft pericardium patches. Clinical results and follow-up results were compared. Results There were 1 operative death in Gore-tex patch group (7. 7%), and 1 early postoperative death in cryopreserved homograft pericardium patch group (6. 7%). Hemostasia time, the pericardial cavity drainage volume in cryopreserved homograft pericardium patch group were less than those in Gore-tex patch group (P〈0. 01). All patients were followed-up for 0.8-4.5years. The residual obstruction rate at RVOT level in Gore-tex patch group was higher than that in cryopreserved homograft pericardium patch group by echocardiography (P〈0.01). No calcification shadow was found on the chest X-ray. Conclusion Homograft pericardium is the tissue with high density and intensity, its elasticity and compliance are good. Using homograft pericardium patch may be helpful to decrease the residual obstruction of RVOT after operation. It can be adapted as a repairing material in heart surgery.