west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "三维重建" 101 results
  • Study on Peribiliary Vascular Plexus of Hepatic Portal Bile Duct in Rats

    【Abstract】Objective To investigate the anatomic structure and experimental methods of peribiliary vascular plexus(PVP) in rat’s hepatic portal bile duct.Methods To observe the morphological structure of PVP in rat’s hepatic portal bile duct after the hepatic artery was perfused with Chinese ink and transparency management, performed and to make three dimensional reconstruction of PVP’s spacial structure in MoticBuaa3Dvol software.Results The microvascular distribution and plane structure of PVP in rat’s hepatic portal bile duct could be shown clearly through Chinese ink perfusion and transparency management. The three dimensional structure of PVP could be reconstructed effectively by MoticBuaa3Dvol software, its effect was verisimilitude. Conclusion Chinese ink perfusion and vitrification is a simple and easy method in PVP’s morphologic study of rat’s hepatic portal bile duct. MoticBuaa3Dvol software is useful in microvascular study of hepatic portal bile duct.

    Release date:2016-09-08 11:54 Export PDF Favorites Scan
  • The Diagnostic Value of Spiral CT Reconstruction in Talus Fractures

    目的:研究距骨骨折螺旋CT轴扫、多平面(MPR)和三维(3D)重建图像的特点及其临床意义。方法:收集距骨骨折患者术前螺旋CT资料12例,同时进行了MPR和3D重建图像。着重分析距骨骨折线的走行、与关节面的关系、关节面塌陷程度等,并评价轴扫、MPR和3D重建图像的优势。结果:在12例距骨骨折者骨踝关节受累7例。MPR和3D重建图像可直观显示骨折详细情况。结论:螺旋CT轴扫、多平面和三维重建图像相结合,可更好显示距骨骨折的情况,能为临床术前诊断和治疗提供有价值的影像信息。

    Release date:2016-09-08 09:56 Export PDF Favorites Scan
  • 先天性心脏病合并气管性支气管伴支气管狭窄一例

    Release date:2020-01-17 05:18 Export PDF Favorites Scan
  • Computer-simulated osteotomy based on health-side combined with guide plate technique in treatment of cubitus varus deformity in adolescents

    Objective To explore the feasibility and early effectiveness of computer-simulated osteotomy based on the health-side combined with guide plate technique in the treatment of cubitus varus deformity in adolescents. Methods The clinical data of 23 patients with cubitus varus deformity who met the selection criteria between June 2019 and February 2023 were retrospectively analyzed. There were 17 males and 6 females, ranging in age from 4 to 16 years with an average of 8.5 years. The time from injury to operation was 1-4 years. The angle of distal humerus rotation was defined by humeral head posterior inclination angle using low radiation dose CT to scan the patient’s upper extremity data at one time, and the preoperative rotation of the distal humerus on the affected side was (33.82±4.39)°. The CT plain scan data were imported into 9yuan3D digital orthopaedic system (V3.34 software) to reconstruct three-dimensional images of both upper extremities. The simulated operation was performed with the healthy upper extremity as the reference, the best osteotomy scheme was planned, overlapped and compared, and the osteotomy guide plate was prepared. The patients were followed up regularly after operation, and the formation of callus in the osteotomy area was observed by X-ray examination. Before and after operation, the carrying angle of both upper extremities (the angle of cubitus valgus was positive, and the angle of cubitus varus was negative) and anteversion angle were measured on X-ray and CT images. At the same time, the flexion and extension range of motion of elbow joint and the external rotation range of motion of upper extremity were measured, and Mayo score was used to evaluate the function of elbow joint. ResultsThe operation time ranged from 34 to 46 minutes, with an average of 39 minutes. All patients were followed up 5-26 months, with a mean of 14.9 months. All the incisions healed by first intention after the operation; 2 patients had nail path irritation symptoms after Kirschner wire fixation, which improved after dressing change; no complication such as breakage and loosening of internal fixators occurred after regular X-ray review. Continuous callus formed at the osteotomy end at 4 weeks after operation, and the osteotomy end healed at 8-12 weeks after operation. At last follow-up, the carrying angle, anteversion angle, external rotation range of motion, and extension and flexion range of motion of the elbow joint of the affected side significantly improved when compared with preoperative ones (P<0.05). Except for the extension range of motion of the healthy elbow joint (P<0.05), there was no significant difference in other indicators between the two sides (P>0.05). At last follow-up, the Mayo elbow score was 85-100, with an average of 99.3; 22 cases were excellent, 1 case was good, and the excellent and good rate was 100%. ConclusionComputer-simulated osteotomy based on health-side combined with guide plate technique for treating cubitus varus deformity in adolescents can achieve precise osteotomy, which has the advantages of short operation time and easy operation, and the short-term effectiveness is satisfactory.

    Release date:2023-10-11 10:17 Export PDF Favorites Scan
  • THREE DIMENSIONAL VISUAL RESEARCH OF THORACIC DORSAL ARTERY BASED ON CT ANGIOGRAPHY

    ObjectiveTo study the digital anatomy and application value of the thoracic dorsal artery based on CT angiography (CTA). MethodsBetween September 2012 and June 2014, aorta CTA images were chosen from 10 cases (20 sides) undergoing aorta CTA. By using Mimics 17.0 software for three dimensional (3D) reconstruction of image post-processing, the digital vascular anatomical information were obtained after observing and measuring the origin of the thoracic dorsal artery, the number of perforators, type, inner diameter, and pedicle length; and the body surface location of perforator vessel was determined, and then the thoracic dorsal artery perforators tissue flap harvesting was simulated. Results3D reconstruction images showed that the thoracic dorsal artery originated from subscapular artery, 76 perforator vessels were found, including 32 perforators (42.1%) from the medial branch of the thoracic dorsal artery and 44 perforators (57.9%) from the lateral branch of the thoracic dorsal artery, of which 69 were intramuscular perforators (90.8%) and 7 were direct skin artery (9.2%). The inner diameter of the thoracic dorsal artery was (1.69±0.23) mm, and its pedicle length was (2.12±0.64) cm. The first lateral perforator of the thoracic dorsal artery located at (1.65±0.42) cm above the horizontal line of the inferior angle of scapula and at (1.68±0.31) cm lateral to vertical line of the inferior angle of scapula. The first medial perforator located at (1.43 ±0.28) cm above the horizontal line of the inferior angle of scapula and at (1.41±0.28) cm lateral to vertical line of the inferior angle of scapula. The thoracic dorsal artery perforators flap harvesting was successfully simulated. ConclusionCTA is a more intuitive method to study the thoracic dorsal artery in vivo, it can clearly display 3D information of the main blood supply artery course and distribution after flap reconstruction, so it can effectively and accurately guide the design of the flap.

    Release date: Export PDF Favorites Scan
  • Chinese expert consensus on the application of integrated 3D reconstruction with artificial intelligence in thoracic surgery

    In order to further regulate the application of 3D reconstruction in thoracic surgery, the Chinese Expert Consensus Group on the Application of Integrated 3D Reconstruction with Artificial Intelligence in Thoracic Surgery conducted discussions and developed this consensus. This consensus is based on the clinical experience and existing prospective or retrospective studies of 3D reconstruction technology in various scenarios of thoracic surgery and summarizes recommendations, and also appends a list of 3D reconstruction technology application scenarios that are currently controversial, not fully studied, or still in the exploratory stage, to provide direction and evidence for future clinical research and disease diagnosis and treatment, and to reach a consensus.

    Release date:2023-05-09 03:11 Export PDF Favorites Scan
  • Diagnostic value of three-dimensional reconstruction technique in new classification criteria of lung adenocarcinoma

    ObjectiveTo evaluate the application value of three-dimensional (3D) reconstruction in preoperative surgical diagnosis of new classification criteria for lung adenocarcinoma, which is helpful to develop a deep learning model of artificial intelligence in the auxiliary diagnosis and treatment of lung cancer.MethodsThe clinical data of 173 patients with ground-glass lung nodules with a diameter of ≤2 cm, who were admitted from October 2018 to June 2020 in our hospital were retrospectively analyzed. Among them, 55 were males and 118 were females with a median age of 61 (28-82) years. Pulmonary nodules in different parts of the same patient were treated as independent events, and a total of 181 subjects were included. According to the new classification criteria of pathological types, they were divided into pre-invasive lesions (atypical adenomatous hyperplasia and and adenocarcinoma in situ), minimally invasive adenocarcinoma and invasive adenocarcinoma. The relationship between 3D reconstruction parameters and different pathological subtypes of lung adenocarcinoma, and their diagnostic values were analyzed by multiplanar reconstruction and volume reconstruction techniques.ResultsIn different pathological types of lung adenocarcinoma, the diameter of lung nodules (P<0.001), average CT value (P<0.001), consolidation/tumor ratio (CTR, P<0.001), type of nodules (P<0.001), nodular morphology (P<0.001), pleural indenlation sign (P<0.001), air bronchogram sign (P=0.010), vascular access inside the nodule (P=0.005), TNM staging (P<0.001) were significantly different, while nodule growth sites were not (P=0.054). At the same time, it was also found that with the increased invasiveness of different pathological subtypes of lung adenocarcinoma, the proportion of dominant signs of each group gradually increased. Meanwhile, nodule diameter and the average CT value or CTR were independent risk factors for malignant degree of lung adenocarcinoma.ConclusionImaging signs of lung adenocarcinoma in 3D reconstruction, including nodule diameter, the average CT value, CTR, shape, type, vascular access conditions, air bronchogram sign, pleural indenlation sign, play an important role in the diagnosis of lung adenocarcinoma subtype and can provide guidance for personalized therapy to patients in clinics.

    Release date:2021-03-19 01:41 Export PDF Favorites Scan
  • Application of Digital Technology Assisted Minimally Invasive Surgery in Diagnosis and Treatment of Hepatolithiasis

    ObjectiveTo study the clinical value of digital technology assisted minimally invasive surgery in diagnosis and treatment of hepatolithiasis. MethodsThe image data of 64-slice spiral CT scanning were obtained from five patients of complicated hepatolithiasis and introduced into medical image three-dimensional visualization system (MI-3DVS) for three-dimensional reconstruction. On the basis of the data of three-dimensional reconstruction, minimally invasive surgical planning of preoperation was made to obtain reasonable hepatectomy and cholangiojejunostomy, and then preoperative emulational surgery was carried out to minimize the extent of tissue damage and provide guidance to actual operation. ResultsLiver, biliary system, stone, blood vessel, and epigastric visceral organ were successfully reconstructed by MI-3DVS, which showed clearly size, number, shape, and space distribution of stone, and location, degree, length, and space distribution of biliary stricture, and anatomical relationship of ducts and vessels. The results of three-dimensional reconstruction were successfully confirmed by actual operation, which was in accordance with emulational surgery. There was no operative complication. No retained stone in internal and external bile duct was found by Ttube or other supporting tube cholangiography on one month after operation. ConclusionThree-dimensional digitizing reconstruction and individual emulational surgery have important significance in diagnosis and treatment of complicated hepatolithiasis by minimally invasive technique.

    Release date:2016-09-08 10:41 Export PDF Favorites Scan
  • Design of visualized medical images network and web platform based on MeVisLab

    With the trend of the development of "Internet +", some further requirements for the mobility of medical images have been required in the medical field. In view of this demand, this paper presents a web-based visual medical imaging platform. First, the feasibility of medical imaging is analyzed and technical points. CT (Computed Tomography) or MRI (Magnetic Resonance Imaging) images are reconstructed three-dimensionally by MeVisLab and packaged as X3D (Extensible 3D Graphics) files shown in the present paper. Then, the B/S (Browser/Server) system specially designed for 3D image is designed by using the HTML 5 and WebGL rendering engine library, and the X3D image file is parsed and rendered by the system. The results of this study showed that the platform was suitable for multiple operating systems to realize the platform-crossing and mobilization of medical image data. The development of medical imaging platform is also pointed out in this paper. It notes that web application technology will not only promote the sharing of medical image data, but also facilitate image-based medical remote consultations and distance learning.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
  • RECONSTRUCTION OF MANDIBULAR BONE DEFECTS USING THREE-DIMENSIONAL SKULL MODEL AND INDIVIDUALIZED TITANIUM PROSTHETICS FROM COMPUTER ASSISTED DESIGN

    【Abstract】 Objective To evaluate the feasibility and effectiveness of reconstruction of mandibular bone defects using three-dimensional skull model and individualized titanium prosthetics from computer assisted design. Methods Between July 2002 and November 2009, 9 patients with mandibular defects accepted restorative operation using individualized bone prosthetics. Among 9 cases, 4 were male and 5 were female, aged 19-55 years. The causes of mandibulectomy were benign lesions in 8 patients and carcinoma of gingival in 1 patient. Mandibular defects exceeded midline in 2 cases, involved condylar in 4 cases, and was limited in one side without involvement of temporo-mandibular joint in 3 cases. The range of bone defects was 9.0 cm × 2.5 cm-17.0 cm × 2.5 cm. The preoperative spiral CT scan was performed and three-diamensional skull model was obtained. Titanium prosthetics of mandibular defects were designed and fabricated through multi-step procedure of reverse engineering and rapid prototyping. Titanium prosthetics were used for one-stage repair of mandibular bone defects, then two-stage implant denture was performed after 6 months. Results The individualized titanium prosthetics were inserted smoothly with one-stage operative time of 10-23 minutes. All the cases achieved incision healing by first intention and the oblique mandibular movement was corrected. They all got satisfactory face, had satisfactory contour and good occlusion. In two-stage operation, no loosening of the implants was observed and the abutments were in good position with corresponding teeth which were designed ideally before operation. All cases got satisfactory results after 1-9 years of follow-up. At last follow-up, X-ray examinations showed no loosening of implants with symmetry contour. Conclusion Computer assisted design and three-dimensional skull model techniques could accomplish the design and manufacture of individualized prosthetic for the repair of mandibular bone defects.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
11 pages Previous 1 2 3 ... 11 Next

Format

Content