find Keyword "义眼" 2 results
  • 眶内置入物的临床应用

    作者报道42例眼球缺失患者,采用高分子材料作眶内置入物,然后装配义眼。在随访观察中,有4例在术后3~6个月,出现置入物部分外露,2例眶内移位,7例在术后6个月,置入物脱出。作者讨论了置入物材料的选择,以及并发症的处理等。

    Release date:2016-09-01 11:41 Export PDF Favorites Scan
  • INITIATIVE REPORT OF THE HYDROXYAPATITE ORBITAL IMPLANT DRILLING PROCEDURE

    OBJECTIVE: To evaluate the clinical effect of drilling procedure following the hydroxyapatite orbital implantation. METHODS: From February 1996 to April 2000, 146 consecutive patients who received hydroxyapatite orbital implant were drilled and inserted a motility peg 6 to 16 months after hydroxyapatite implantation. Among them, there were 97 males and 49 females, aged from 18 to 60 years old, of the 146 motility pegs, 36 were sleeved pegs and 110 were nonsleeved. Goldman visual field analyzer was applied to measure the degree of artificial eye’s movement before and after drilling. RESULTS: Followed up for 1 to 40 months, no secondary infection occurred. The mobility of the prosthesis increased from (18.7 +/- 3.8) degrees preoperatively to (42.3 +/- 3.7) degrees postoperatively. CONCLUSION: The delayed drilling procedure and motility peg insertion improve the range of movement and the sensitivity of the artificial eye with a low rate of complications.

    Release date:2016-09-01 10:21 Export PDF Favorites Scan