Objective To observe whether the adoptation of tricuspid annulus diameter as surgical indication for tricuspid annuloplasty will reduce the occurrence of moderate-severe tricuspid regurgitation(TR) in patients after mitral valve replacement (MVR). Methods Between April 2005 and June 2006, MVR was performed in 56 patients with no or mild TR in our Department. The patients were divided into two groups according to tricuspid annulus diameter(TAD)/body surface area (BSA)≥21mm/m2. Tricuspid annuloplasty group(TA group): 22 cases, male 8, female 14, age 45.0±7.7 years, TAD 36.8±3.8mm, BSA 1.57±0.15m2, New York Heart Association(NYHA) functional class Ⅲ/Ⅲ-Ⅳ 18/4, sinus rhythm(SR)/atrial fibrillation (AF) 2/20. Notricuspid annuloplasty group (NTA group): 34 cases, male 9, female 25, age 42.9±11.0 years, TAD 28.5±4.4mm, BSA 1.58±0.13m2, NYHA Ⅲ/Ⅲ-Ⅳ 28/6, SR/AF 9/25. Kay annuloplasty was performed for TA group patients. The patients were followed in outpatient clinical regularly and evaluated by echocardiography at 6 months after operation. Results All patients recovered and were discharged from hospital. The duration of follow-up was 11.0±2.4 months. Except 2 cases, all patients received echocardiography evaluation at 6 months after operation. There were no significantly differences between two groups patients in general clinical characteristics (Pgt;0.05). Compared with NTA group before operation, right atrial diameter (RAD, 49.3±7.0mm) and TAD(36.8±3.8mm) were bigger and more mild TR in TA group (Plt;0.05). RAD(44.1±8.9mm) and TAD(28.9±6.1mm) reduced and the proportion of TR degree improved (Plt;0.05) in TA group but did not occur in NTA group after surgery (Pgt;0.05). There were three cases of moderate TR in NTA group. Conclusion Tricuspid annuloplasty adopting TAD as surgical indication may reduce the occurrences of postoperative moderate-severe TR for patients of MVR with no or mild preoperative TR.
Abstract: Objective To evaluate the early and late results of mitral valve replacement with home made C-L pugesturt tilting disc and analyse the factors which impact on the therapeutic effect,so as to elevate the operative effect. Methods A retrospective study was made on the result of clinical data and longterm followup of 259 patients who had undergone the Chinesemade C-L pugesturt tilting disc mechanical valve replacement from October 1991 to November 2006. Results The data showed that there were 12 patients died in the duration of hospital stay.The hospital mortality was 4.63% (12/259).There were no mechanical valverelated complication in the earlier postoperative period.The mortality fell to 2.59% since 1996.Among the 235 patients,12 patients were lost during the followup,the rate of followup was 95.1%(235/247).The time for followup was 9.77±3.09 years. There were 26 late deaths.During the follow-up,death associated with the deterioration of valve structure were not observed. The 5 years, 10 years and l5 years survival rates were 86.80%±2.30%, 78.20%±3.33% and 55.23%±4.34% respectively; the thromboembolic event free rates for 5 years, 10 years and l5 years were 95.95%±0.74%, 92.52%±4.11% and 80.52%±4.11% respectively; the anticoagulant related bleeding free rates for 5 years, 10 years and l5 years were 94.64%±1.75%, 89.55%±3.28% and 79.39%±4.43% respectively.There were 141 patients(67.46%) in New York Heart Association(NYHA) classⅠ, 56 patients(26.79%) in class Ⅱ, 10 patients(4.78%) in class Ⅲ and 2 patients(0.95%) in class Ⅳ. Conclusion The results of follow-up for 15 years suggest that the Chinesemade C-L pugesturt tilting disc medical mechanical valve is a reliable and safe choice for mitral valve replacement.
Abstract: Objective To summarize our experience and clinical outcomes of preservation of posterior leaflet and subvalvular structures in mitral valve replacement(MVR). Methods We retrospectively analyzed the clinical data of 1 035 patients who underwent MVR in Beijing An Zhen Hospital from January 2006 to March 2011. There were 562 male patients and 473 female patients with their age of 37-78(53.84±13.13)years old. There were 712 patients with rheumatic valvular heart disease and 323 patients with degenerative valve disease, 389 patients with mitral stenosis and 646 patients with mitral regurgitation. No patient had coronary artery disease in this group. For 457 patients in non-preservation group, bothleaflets and corresponding chordal excision was performed, while for 578 patients in preservation group, posterior leafletand subvalvular structures were preserved. There was no statistical difference in demographic and preoperative clinical characteristics between the two groups. Postoperative mortality and morbidity, and left ventricular size and function were compared between the two groups. Results There was no statistical difference in postoperative mortality(2.63% vs. 1.21%, P =0.091)and morbidity (8.53% vs. 7.44%, P=0.519)between the non-preservation group and preservation group, except that the rate of left ventricular rupture of non-preservation group was significantly higher than that of preservation group(1.09% vs. 0.00%, P=0.012). The average left ventricular end-diastolic dimension (LVEDD)measured by echocardiography 6 months after surgery decreased in both groups, but there was no statistical difference between the two groups. The average left ventricular ejection fraction (LVEF) 6 months after surgery was significantly improved compared with preoperative average LVEF in both groups. The average LVEF 6 months after surgery in patients with mitral regurgitation in the preservation group was significantly higher than that in non-preservation group (56.00%±3.47% vs. 53.00%±3.13%,P =0.000), and there was no statistical difference in the average LVEF 6 months after surgery in patients with mitral stenosis between the two groups(57.00%±5.58% vs. 56.00%±4.79%,P =0.066). Conclusion Preservation of posterior leaflet and subvalvular structures in MVR is a safe and effective surgical technique to reduce the risk of left ventricle rupture and improve postoperative left ventricular function.
ObjectiveTo investigate the restoration of left atrial function and its relationship with atrial fibrosis of patients after mitral valve replacement (MVR)and concomitant radiofrequency ablation (RFA)for atrial fibrillation (AF). MethodsClinical data of 32 patients with mitral valve disease and chronic AF who underwent surgical treatment in General Hospital of Shenyang Military Area Command from January to August 2010 were retrospectively analyzed in this cohort study. There were 11 male and 21 female patients with their age of 49.8±8.7 years. There were 14 patients with rheumatic mitral stenosis (MS), 8 patients with rheumatic MS and mitral regurgitation, and 10 patients with mitral valve prolapse. Preoperative AF duration was 3.6±4.6 years. All the patients received MVR and concomitant RFA for AF. According to the cutting off extent of left atrial fibrosis (10.9%), all the 32 patients were divided into 2 groups. There were 19 patients with more severe left atrial fibrosis ( > 10.9%)in group A and 13 patients with milder left atrial fibrosis ( < 10.9%)in group B. Immunohistochemistry was performed to examined left atrial fibrosis, and echocardiography was performed to examined the structure and function of left atrium. ResultsThere was no perioperative death. Cardiopulmonary bypass time was 84.6±22.6 minutes, aortic cross-clamping time was 47.6±15.6 minutes, and ICU stay was 3.2±1.5 days. All the 32 patients were followed up for longer than 6 months (1.3±0.6 years). The extent of left atrial fibrosis of the 32 patients was 4.8%-18.3% (10.7%±4.2%). There was no statistical difference in left atrial diameter (LAD), left atrial fractional area change (LAFAC)or mitral annular motion between group A and group B preoperatively and 3 months after surgery respectively (P > 0.05). At 6 month after surgery, LAD of group B was significantly smaller than that of group A (P < 0.05), late diastolic mitral annular velocity (Am)of group B was significantly higher than that of group A (P < 0.05), and there was also some improvement in LAFAC of group B compared with group A (P=0.067). Among the 32 patients, 28 patients (87.5%)restored sinus rhythm (SR)3 months after surgery, and 21 patients (65.6%)maintained SR longer than 6 months after surgery. Patients in group B were more likely to maintain SR than patients in group A (P=0.010). ConclusionImprovement of left atrial function can be observed 6 month after MVR and concomitant RFA for AF, which is related to the extent of left atrial fibrosis.
Objective To investigate and evaluate the safety and effectiveness of the Chimney technique in mitral valve reoperation. Methods The clinical data of mitral valve reoperation patients who underwent Chimney surgery in Wuhan Asia Heart Hospital from 2019 to 2021 were retrospectively analyzed. Results A total of 26 patients were collected, including 7 males and 19 females, aged 27-67 (53.46±11.18) years. All patients had previous mitral valve surgery, including 23 mitral valve replacements and 3 mitral valve repairs. All patients received Chimney technique using the ideal artificial sized mitral valve, and 1 patient died of neurological complications in hospital. The cardiopulmonary bypass time and the aortic cross-clamping time were 231.11±77.05 min and 148.50±52.70 min, respectively. The mean diameter of the implanted mitral valve prosthesis was 29.08±0.68 mm, which was statistically different from pre-replacement valve prosthesis size of 26.69±0.77 mm (P<0.001). The mean transvalvular pressure gradient of the prosthetic mitral valve measured on postoperative echocardiography was 14.77±5.34 mm Hg, which was statistically different from preoperative value of 20.92±9.83 mm Hg (P=0.005). Conclusion The Chimney technique is safe and effective for reoperation in patients with small mitral annuli, which can not only reduce the risk of reoperation, but also obtain larger prosthetic valve implants with good hemodynamic characteristics and clinical outcomes.