west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "于坤" 4 results
  • Bivalirudin Anticoagulation for Cardiac Surgery

    Heparin has long been a preferred anticoagulant during cardiovascular surgery, although limitations exist, including heparin-induced thrombocytopenia (HIT) and/or anti-platelet factor Ⅳ/heparin (anti-PF4/H) antibodies. Bivalirudin is a direct thrombin inhibitor, which can overcome the shortcoming of heparin. This article reviewed the application of bivalirudin in the field of cardiac surgery, its safety and effectiveness in various surgical treatments as well as summarized the standard protocol, doses, monitoring parameters and targets of bivalirudin for anticoagulation in cardiac surgery and mechanical circulation support. Bivalirudin as an alternative to heparin provides a new selection for anticoagulation in cardiac surgery.

    Release date:2016-12-06 05:27 Export PDF Favorites Scan
  • Comparison of Clinical Applications Between Two Different Extracorporeal Membrane Oxygenation Systems

    Abstract: Objective To summarize the clinical experiences of performing extracorporeal membrane oxygenation (ECMO) on patients with heart and respiratory failure, and compare the clinical outcomes of Medtronic system and Quadrox PLS system. Methods We retrospectively analyzed the clinical data of 121 heart and respiratory failure patients who underwent ECMO treatment in Fu Wai Hospital from December 2004 to December 2009. Based on the different systems used, 121 patients were divided into two groups. In group M, there were 65 patients including 41 males and 24 females, with an age of 26.6±25.9 years; and they accepted Medtronic ECMO system treatment. In group Q, there were 56 patients including 39 males and 17 females, with an age of 32.4±23.9 years and they underwent Quadrox PLS ECMO system treatment. The evaluation of the clinical outcomes of these two different systems was based on the comparison of transmembrane pressure drop (TMPD), anticoagulation, hemolysis, plasma leakage, organ function, complication and hospital mortality between the two groups. Results Compared with group M, ECMO with Quadrox PLS system was associated with lower TMPD (at the beginning of ECMO: 15.0±6.0 mm Hg vs.28.0±5.0 mm Hg, P=0.000; 24 hours later: 16.0±5.0 mm Hg vs. 30.0±7.0 mm Hg, P=0.000) and less thrombus formation(7.1% vs.23.1%, P=0.037), less plasma leakage (0.0% vs. 50.8%, P=0.000), less hemolysis (14.3% vs. 29.2%, P=0.047). There were no significant differences between the two groups in support duration, complication rate, and hospital mortality(Pgt;0.05). Conclusion Both devices have similar effects for safe clinical application, but Quadrox PLS ECMO system has a relatively high biocompatibility with lower TMPD, less plasma leakage, and thrombus formation.

    Release date: Export PDF Favorites Scan
  • 婴幼儿心脏手术采用全胶体预充的临床观察

    目的 观察婴幼儿心脏直视手术中, 体外循环应用全胶体预充液对术中和术后液体平衡、出血和输血量的影响. 方法 收集全胶体预充前后先天性心脏病患者临床资料151例,分别作为对照组和全胶体预充组,比较两组患者血液制品用量、胸腔引流液量、术中和术后液体出入情况以及临床恢复情况. 结果 全胶体预充组白蛋白用量多,术中超滤量、液体入量和尿量较少,术后速尿用量多;其余差别无显著性意义. 结论 婴幼儿体外循环全胶体预充有利于减少术中的液体入量.

    Release date:2016-08-30 06:31 Export PDF Favorites Scan
  • Myocardial Protection of Sevoflurane Used in the Whole Process of Cardiopulmonary Bypass:A RandomizControlled Trial HU Qiang,GAO Guo-dong,YU Kun,JIANG Fu-qing,LONG Cun.

    Abstract: Objective To observe myocardial protective effect of sevoflurane used in the whole process of cardiopulmonary bypass(CPB). Methods A total of 150 patients older than 18 years who underwent cardiac surgery under CPB in Fu wai Hospital from January 2010 to November 2011 were enrolled in this double-blind and randomized controlled study. All the patients were randomly divided into three groups:Sevoflurane pretreatment group (Group A,n=50),whole-process Sevoflurane group (Group B,n=50),and whole-process intravenous anesthesia group (Group C,n=50). Radial artery pressure and other hemodynamic parameters were continuously measured for all the patients. At following time points: CPB beginning (T1),aortic declamping (T2),3 hours after aortic declamping (T3),and 24 hours after aortic declamping (T4),serum concentrations of cardiac troponin I (cTnI) and other parameters were measured by enzyme-linked immunosorbent assay (ELISA). Results There were 31 males and 19 females at age of 60.43±3.24 years in group A,28 males and 22 females at age of 59.88±4.12 years in group B,31 males and 19 females at age of 58.76±3.87 years. There was no statistical difference in mean arterial pressure (MAP),central venous pressure (CVP),pulmonary artery wedge pressure (PAWP) and heart rate (HR) at respective time points among the 3 groups (P>0.05). At T1 and T2,there was no statistical difference in cardiac index (CI) among the 3 groups (P>0.05). At T3,there was no statistical difference in CI between Group A and Group C(F=3.382,P=0.845),but CI of Group B was significantly higher than that of Group A and C(F=3.382,3.382; P=0.033,0.020). At T4,CI of Group B was significantly higher than that of Group A and C (F=13.324,13.324; P=0.005,P=0.000),and CI of Group A was significantly higher than that of Group C (F=13.324,P=0.024). At T1 and T2,there was no statistical difference in serum concentrations of creatinine kinase MB (CK-MB),cTnI,interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α) among the 3 groups (P>0.05). At T3 and T4,serum concentrations of CK-MB,TNF-α,IL-6 and cTnI of Group C were significantly higher than those of Group A,and serum concentrations of CK-MB,TNF-α,IL-6 and cTnI of Group A were significantly higher than those of Group B (F=531.616,5.410,3.5813,3.160,1.126,4.702,7.819,5.424,all P=0.000). Conclusion Sevoflurane used in the whole process of CPB has definite myocardial protective effect which is ber than that of Sevoflurane pretreatment.

    Release date:2016-08-30 05:47 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content