west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "任荣" 7 results
  • Quality evaluation and genetic study of anti-coagulation therapy of warfarin in stable period after mechanical valve replacement

    ObjectiveTo evaluate the quality of warfarin anticoagulant therapy in patients with stable stage after mechanical valve replacement surgery, to observe the effect of compound salvia miltiorrhiza tablet on the anticoagulant effect of warfarin in patients after mechanical valve replacement, and to understand the impact of genetic polymorphisms of VKORC1, CYP2C9 and CYP4F2 on warfarin resistance in patients with mechanical valve replacement in the stable period.MethodsFrom July 2011 to February 2014, 1 831 patients who had ≥ 6 months after mechanical valve replacement surgery were enrolled at the outpatient follow-up. The basic clinical data were recorded. Anticoagulant therapy uses a target international normalized ratio(INR, 1.60–2.20) and a weekly warfarin dose adjustment strategy. Forty-six patients who needed compound salvia miltiorrhiza tablet were screened and the INR values. Before and after taking tablets were recorded and compared. The patients were divided into three groups according to the percentile of warfarin dosage including a warfarin sensitive patients group, a control patients group, and a warfarin resistance patients group. And 101 of them were selected. TIANGEN blood DNA Kit blood genomic DNA extraction kit was used to extract samples and polymerase chain restriction fragment length polymorphism (PCR-RELP) was used to determine the genotypes of patients. The detected gene loci included CYP4F2: rs2108622C>T locus; VKORC1:1639G>A locus; VKORC1:1173C>T locus; CYP2C9*2: rs1799853C>T locus; CYP2C9*3:1061A>C locus.ResultsThe time in therapeutic range (TTR) and fraction of time in therapeutic range (FTTR) in the target INR range of the patients included in the study period was 27.2% and 49.4%, respectively, and the TTR and FTTR in the acceptable INR range was 34.25% and 63.36%, respectively. Before and after the addition of compound salvia miltiorrhiza tablets, the INR value was 1.55±0.03 and 1.69±0.30, respectively, and the difference was statistically different (P<0.05). A total of 101 patients with genetic testing, in which the C/T composition of the VKORC1: 1173C>T locus increased in the warfarin sensitivity, contrast and warfarin resistance patients, while the ratio of allelic loci of C/T in CYP2C9*3: 1061A>C loci decreased in turn. There was no difference in the CYP4F2 gene, VKORC1639 gene, and CYP2C9*2 locus. The IWPC model predicts that warfarin dose is only consistent with the actual warfarin dose in warfarin sensitive patients.ConclusionRelatively low TTR and FTTR are acceptable in patients with stable stage after mechanical valve replacement. It is beneficial to the patients with compound salvia miltiorrhiza tablets in terms of some appropriate patients. VKORC1: 1173C>T site and CYP2C9*3: 1061A>C site mutation is the main pharmacological gene factor of warfarin dose sensitivity and warfarin resistance in stable period after mechanical valve replacement. The IWPC dose prediction model is only consistent with the actual dose of warfarin sensitive patients.

    Release date:2019-06-18 10:20 Export PDF Favorites Scan
  • 可吸收螺钉结合可吸收缝线张力带治疗青少年髂前上棘撕脱骨折

    目的 总结采用可吸收螺钉结合可吸收缝线张力带治疗青少年髂前上棘撕脱骨折的疗效。 方法 2006 年12 月- 2009 年6 月,采用切开复位可吸收螺钉结合可吸收缝线张力带治疗15 例青少年髂前上棘撕脱骨折。患者均为男性;年龄13 ~ 16 岁,平均14.6 岁。左侧4 例,右侧10 例,双侧1 例。均为运动损伤。X 线片示髂前上棘撕脱骨折,骨折块分离移位1.5 ~ 3.0 cm。受伤至手术时间约3 d。 结果 术后切口均Ⅰ期愈合。15 例均获随访,随访时间3 ~ 12 个月,平均6 个月。患髋活动均良好,无跛行,患处及行走无疼痛,髂前上棘外观恢复满意。术后3 个月X 线片示骨折均达骨性愈合。缝匠肌肌力5 级,可参加体育锻炼。1 例术后大腿外侧皮肤感觉减弱,随访3 个月后皮肤感觉恢复正常;余无延迟愈合、感染、屈髋功能障碍等并发症。 结论 可吸收螺钉结合可吸收缝线张力带固定是治疗青少年髂前上棘撕脱骨折的一种有效方法。

    Release date:2016-08-31 05:48 Export PDF Favorites Scan
  • Long-term Echocardiographic Outcomes of Patients after Mitral and Aortic Valve Replacement and their Clinical Significance

    ObjectiveTo investigate long-term echocardiographic outcomes of patients after mitral and aortic valve replacement and their clinical significance. MethodsA total of 204 patients who underwent mitral and aortic valve replacement from January 1999 to June 2008 in West China Hospital of Sichuan University, and had been followed up with echocardiography for longer than 5 years were enrolled in this study. There were 60 male and 144 female patients with their age ranging from 15 to 74 (48.42±11.00)years. Postoperative follow-up time was 5 to 13 (6.34±2.05)years. Preoperative and follow-up echocardiographic results were compared. ResultsCompared with preoperative results, postoperative left atrial diameter (LA)and left ventricular diameter (LV)significantly decreased (P < 0.05), while right ventricular diameter (RV), left ventricular ejection fraction (LVEF)and left ventricular fractional shortening (LVFS)significantly increased (P < 0.05). Right atrial diameter (RA)did not change significantly (P > 0.05). In the patients mainly with mitral stenosis preoperatively, postoperative LA, LV, left atrial area (LAA), left atrial volume (LAV), mitral mean pressure gradient (MPGmv), velocity time integral (VTImv)and pressure half time (PHTmv)significantly decreased (P < 0.05), while mitral effective orifice area (EOAmv)and effective orifice area index (EOAImv)increased significantly (P < 0.05), but peak E velocity (Emv)did not change significantly (P > 0.05). In the patients mainly with mitral regurgitation preoperatively, postoperative LA and LV decreased significantly (P < 0.05), while LAA, LAV, MPGmv, VTImv, PHTmv, EOAmv and EOAImv did not change significantly (P > 0.05). In the patients mainly with aortic stenosis preoperatively, postoperative LV, interventricular septal thickness (IVS), left ventricular mass (LVM), left ventricular mass index (LVMI), aortic peak forward flow velocity(Vav)and mean pressure gradient (MPGav)significantly decreased (P < 0.05), while aortic effective orifice area (EOAav)and effective orifice area index (EOAIav)significantly increased (P < 0.05), but left ventricular posterior wall thickness (LVPW)did not change significantly (P > 0.05). In the patients mainly with aortic regurgitation preoperatively, postoperative LV, LVM, LVMI, EOAav and EOAIav decreased significantly (P < 0.05), while Vav and MPGav increased significantly (P < 0.05), but IVS and LVPW did not change significantly (P > 0.05). In mitral position, compared with patients with 25 mm prosthesis, Emv, MPGmv and VTImv of patients with 27 mm prosthesis were significantly smaller (P < 0.05), but there was no statistical difference in PHTmv, EOAmv or EOAImv between the 2 groups (P > 0.05). In aortic position, compared with patients with 21mm prosthesis, Vav, MPGav and VTIav of patients with 23 mm prosthesis were significantly smaller (P < 0.05), while EOAav and EOAIav were significantly larger (P < 0.05). In mitral position, 38 patients (21.3%)had moderate prothesis-patient mismatch (PPM)and 4 patients (2.3%)had severe PPM. In aortic position, 50 patients (24.5%)had moderate PPM and 43 patients (21.1%)had severe PPM. Consti-tuent ratio of long-term tricuspid regurgitation (TR)degree of patients after tricuspid valvuloplasty (TVP)significantly improved (P < 0.05), but constituent ratio of long-term TR degree of patients without TVP significantly deteriorated (P < 0.05). ConclusionsLeft ventricular function and hemodynamic outcomes in the long term are significantly better than preoperative results after double valve replacement, but they are still far from normal. PPM in aortic position is more severe than that in mitral position. Since residual or aggravated TR is very common in the long term, concomitant TVP should be considered more positively for patients undergoing surgery for left-sided valvular disease.

    Release date: Export PDF Favorites Scan
  • Initial Evaluation of Reasonableness of Target INR 1.60 to 2.20 and Warfarin Weekly Dosage Adjustment in Patients after Mechanical Heart Valve Replacement

    ObjectiveTo evaluate the reasonableness of anticoagulation management strategy in patients after mechanical heart valve replacement. MethodsAll patients were followed and registered continually at outpatient clinic from July 2011 to February 2013, with a minimum of 6 months after surgery. Targeted international normalized rate (INR) 1.60 to 2.20 and warfarin weekly dosage adjustment were used as the strategy of anticoagulation management. Except bleeding, thrombogenesis and thromboembolism, time in therapeutic range (TTR) and fraction of TTR (FTTR) were adopted to evaluate the quality of anticoagulation management. ResultsA total 1 442 patients and 6 461 INR values were included for data analysis. The patients had a mean age of 48.2±10.6 years (14-80 years) and the following up time were 6 to 180 months (39.2±37.4 months) after surgery. Of these patients, 1 043 (72.3%) was female and 399 (27.7%) was male. INR values varied from 0.90-8.39 (1.85±0.49) and required weekly doses of warfarin were 2.50-61.25 (20.89±6.93 mg). TTR of target INR and acceptable INR were 51.1% (156 640.5 days/306 415.0 days), 64.9% (198 856.0 days/306 415.0 days), respectively. FTTR of target INR and acceptable INR were 49.4% (3 193 times/6 461 times), 62.6% (4 047 times/6 461 times). There were 8 major bleeding events, 7 mild bleeding events, 2 thromboembolism events, and 2 thrombogenesis in the left atrium. ConclusionIt is reasonable to use target INR 1.60-2.20 and warfarin weekly dosage adjustment for patients after mechanical heart valve replacement.

    Release date: Export PDF Favorites Scan
  • Early evaluation of quality of anticoagulant therapy in patients with mechanical prosthetic valve replacement through TTR and FTTR

    Objective To evaluate the quality of anticoagulant therapy in patients with mechanical prosthetic valve replacement during early period through time in therapeutic range(TTR) and fraction of time in therapeutic range(FTTR), and to provide an objective evidence for further improving quality of anticoagulant therapy. Methods All the patients were followed and registered in hospital and at outpatient clinic from July 2012 through April 2014, with a maximum of 6 months after surgery. Targeted international normalized rate (INR) was 1.60 to 2.20, acceptable INR was 1.50 to 2.30. And warfarin weekly dosage adjustment was used as the strategy of anticoagulation management. Adjusting the warfarin dosage when INR was beyond acceptable INR. Events of bleeding, thrombogenesis and thromboembolism, TTR and FTTR of these patients during the follow-up were collected to evaluate quality of anticoagulant therapy in these patients. Results A total 477 patients and 2 755 reports of INR values were included for data analysis. The follow-up time was 78 918 days. Values of INR varied from 0.92 to 7.72(1.83±0.64). Required weekly doses of warfarin in target INR and acceptable INR were 5.00–35.00(18.15±3.99) mg/week and 5.00–39.38(18.29±4.08) mg/week. TTR of target INR and acceptable INR was 36.85%(27 079.5 d/78 918.0 d) and 49.84% (39 331.5 d/78 918.0 d), respectively. FTTR of target INR and acceptable INR was 37.31% (1 028 times/2 755 times), 50.01% (1 378 times/2 755 times), respectively. TTR of target INR and acceptable INR was 46.04%(3 902.5 d/8 475.5 d), 59.49%(5 042 d/8 475.5 d) when the patients’ follow-up was up to six months and FTTR of target INR and acceptable INR value of these patients was 46.81%(206 times/440 times), 60.45%(266 times/440 times). During the follow-up, there were 3 thromboembolism events, 1 transient physical abnormal activity, and 1 thrombogenesis in the left atrium, and there was no bleeding and death events. Conclusion The strategy of anticoagulation management used in our study is reasonable. In order to further improve the patients’ quality of anticoagulant therapy, it is necessary to start anticoagulation after operation as soon as possible, to strengthen the education of patients with anticoagulant knowledge and to increase INR test frequency properly.

    Release date:2017-01-22 10:15 Export PDF Favorites Scan
  • Influence factors of the stable warfarin dose in the early period after mechanical prosthetic valve replacement

    Objective Influence factors of the stable warfarin dose in the early period after mechanical prosthetic valve replacement were analyzed to guide the anticoagulation therapy for these patients. Methods A total of 288 patients within 6 months after mechanical prosthetic valve replacement in West China Hospital were followed up and registered at outpatient department from July 2012 to April 2014, including basic information (name, sex, age, height, weight, etc.), general clinical data (cardiac function, heart rate, surgery pattern, etc.) and related data about anticoagulation therapy. The target international standardized ratio (INR) range was 1.60 to 2.20 and the acceptable INR was 1.50 to 2.30. The sex, age, height, body weight, body mass index (BMI), body surface area (BSA) and related clinical factors were analyzed to find the relationship with the dose of warfarin. Results Sex was found to have a significant effect on the stable warfarin dose (P<0.05). Women needed a lower stable warfarin dose than men during the early anticoagulation therapy. There was no significant difference in the stable warfarin dose of patients with different ages, rhythms, NYHA classification, surgery pattern and diseases before operation; but the stable warfarin dose was lower in the patients with radiofrequency ablation during valve replacement procedures than the patients with single valve replacement (P<0.05). There was an association between age, height, weight, BMI, BSA and the stable warfarin dose withR2 of 1.2%, 3.2%, 3.5%, 1.1%, 4.2%, respectively and they could explain 6.1% of variability in warfarin dose. Conclusion During early anticoagulation therapy in patients with mechanical prosthetic valve replacement, it is necessary to consider the effects of various preoperative factors, drug factors and demographic factors on warfarin dose. Even though there is an association between age, height, weight, BMI, BSA and the stable warfarin dose, which can only explain 6.1% of variability in warfarin dose, thus cannot guide the postoperative anticoagulation of these patients.

    Release date:2017-04-24 03:51 Export PDF Favorites Scan
  • Short-term results of sleeve wrapping technique using remnant aortic wall in modified Bentall procedure

    ObjectiveTo evaluate the short-term results of sleeve wrapping technique using remnant aortic wall in modified Bentall procedure. MethodsThe patients undergoing modified Bentall procedure with the remnant aortic wall as a sleeve to cover the sewing area of composite valved graft and the aortic annulus for proximal hemostasis between March 2021 and March 2022 in Shenzhen Fuwai Hospital were enrolled. Short-term results were assessed by cardiopulmonary bypass time, aortic clamping time, mechanical ventilation time, ICU stay, postoperative hospital stay, effusion drainage on the first postoperative day, left ventricular ejection fraction (LVEF), left ventricular end diastolic diameter (LVEDD), and follow-up results. ResultsA total of 14 patients were collected, including 12 males and 2 females, with a mean age of 55.33±10.57 years. There was no postoperative or follow-up death. Cardiopulmonary bypass time was 147.90±21.29 min, aortic clamping time was 115.70±15.23 min, mechanical ventilation time was 19.42±8.98 h, ICU stay was 99.08±49.42 h, and postoperative hospital stay was 16.33±2.74 d. Thoracic drainage volume was 333.33±91.98 mL on the first postoperative day. Only 2 patients required blood transfusion (4.5 U and 2 U, respectively). During the follow-up of 6.17±3.69 months, there was no death, no aortic or valve-related complications. There was statistical difference in the LVEDD between preoperation and before discharge after surgery (P<0.001), and between half a year after surgery and before discharge after surgery (P<0.001). There was a little decrease of LVEF before discharge after surgery compared with preoperative LVEF, but there was no statistical difference (P=0.219). There was no statistical difference in the LVEF half a year after operation compared with that before operation (P=1.000). Conclusion Sleeve wrapping technique using remnant aortic wall in modified Bentall procedure has good short-term results. This modification may be a simple, effective way in controlling proximal bleeding.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content