ObjectiveTo evaluate the clinical value of multi-slice CT in the diagnosis of complications due to breast augmentation. MethodsWe collected the imaging data of 32 female patients who accepted multi-slice CT examination in the second People's Hospital of Chengdu after breast augmentation between February 2010 and February 2015. The position, shape, edge, internal density, leakage, rupture and hard nodules of the prosthesis were observed and analyzed carefully. ResultsIn the 32 patients with breast augmentation, 12 were normal with bilateral symmetry and without abnormal shape or density. Among the other 20 patients, 11 had capsular contracture, 5 had prosthesis leakage, rupture and hard nodules, 4 had breast infection, 1 had fibroadenoma, 1 had cystoma, and 5 had little calcified nodules in the breast tissue. ConclusionThe multi-slice CT scan can clearly and accurately show the position, shape and size of the breast prosthesis as well as the existence of leakage, rupture and hard nodules in the prosthesis. It plays a very important role in the diagnosis of the complications due to breast augmentation and can be effective guidance for clinical operation.
Objective To study the cl inical appl ication of Mobi-C prosthesis in treatment of anterior cervical discectomy and artificial disc replacement (ADR). Methods Between January 2009 and June 2009, 20 cases of degenerative cervical disease were treated with anterior discectomy and ADR by Mobi-C prosthesis, including 13 cases of cervical disc herniation and 7 cases of cervical spondylotic radiculopathy, and 25 Mobi-C prosthesis were implanted. There were 8 males and 12 females, aged 29-54 years (mean, 45.2 years). The disease duration was from 4 days to 5 years (mean, 1.2 years). Affected segments of process included C3, 4 in 1 case, C4, 5 in 2 cases, C5, 6 in 7 cases, C6, 7 in 5 cases, C4, 5 and C5, 6 in 2 cases, and C5, 6 and C6, 7 in 3 cases. Radiographs were taken regularly, and cervical range of motion (ROM) on segments of disc replacements were measured. The functions of cervical spinal cord were evaluated by “40 score” system (COA) preoperatively, immediately postoperatively, and at follow-up. The qual ity of l ife was evaluated by neck disabil ity index (NDI) and visual analogue scale (VAS) score. Results All incisions healed by first intention. No perioperative compl ication was found. All cases were followed up 16.5 months on average (range, 14-18 months). There was no significant difference in cervical ROM of operatied segment between preoperation and follow-up duration (t=0.808,P=0.440). No heterotopic ossification was found at follow-up. COA score at last follow-up (38.20 ± 1.14) was significantly higher than preoperative one (32.10 ± 2.96) , (t=9.278,P=0.000) , and the improvement rate at last follow-up was 77.2% ± 5.4%. VAS score at last follow-up (3.20 ± 1.23) had significant difference when compared with preoperative one (5.10 ± 1.29), (t=10.585,P=0.000). NDI score at last follow-up (29.40 ± 4.55) had significant difference when compared with preoperative one (39.20 ± 3.80), (t=16.039, P=0.000). Conclusion A satisfactory short-term curative effect can be obtained by using Mobi-C prosthesis in treatment of anterior cervical discectomy and ADR.
Objective To discuss the effectiveness of breast reconstruction with dual plane prosthesis implantation or anterior pectoralis prosthesis implantation under endoscopy by using prospective comparative study, in order to provide a reference for clinical surgical selection. Methods A total of 54 female patients with breast cancer admitted between January 2023 and December 2023 and met the selection criteria were selected as research subjects. According to the random number table, 54 patients were divided into trial group and control group with 27 cases in each. The patients in the trial group and control group were treated with dual plane prosthesis implantation and anterior pectoralis prosthesis implantation for breast reconstruction after glandular resection under endoscopy, respectively. There was no significant difference between the two groups (P>0.05) in the terms of age, body mass index, affected side, breast clinical stages, molecular typing, disease duration, breast volume of healthy side, breast ptosis of affected side, and preoperative Breast-Q score (social mental health, sexual health, breast satisfaction, chest somatic health). The operation-related indicators (operation time, total volume of drainage within 7 days after operation, extubation time, and hospital stay), occurrence of complications, breast reconstruction efficacy related indicators (transverse and longitudinal distance difference), and the pre- and post-operative differences (change values) of Breast-Q scores for each item were compared between the two groups. Results There was no significant difference in operation time, total volume of drainage within 7 days after operation, extubation time, and hospital stay between the two groups (P>0.05). All patients of the two groups were followed up 3-12 months (mean, 6.3 months). Three patients (11.11%) in trial group and 5 patients (18.52%) in control group experienced complications, and there was no significant difference in the occurrence of complications (P>0.05). At 7 days after operation, the transverse and longitudinal distance differences were significantly less in trial group than in control group (P<0.05). The Breast-Q scores of the two groups at 7 days after operation were significantly higher in all items than those before operation (P<0.05), but there was no significant difference in all change values between the two groups (P>0.05). ConclusionFor patients with breast cancer, comparison of breast reconstruction with anterior pectoralis prosthesis implantation, breast reconstruction with dual plane prosthesis implantation has better breast reconstruction effectiveness and higher safety.
From March 1986 through March1989 ,silicon rubber prosthesis had been usedfor mammoplasty in 34 patients ( 55breasts) with 53 success and 2 failures. Theindications of surgical treatment , the time tooperate, the mode of implantatioh of prosthe-sis, the selection of prosthesis and the prophy-lactic measures for complications were dis- cussed.
ObjectiveTo evaluate the accuracy of using smartphone to measure the angle of acetabular component in total hip arthroplasty (THA). MethodsBetween June 2012 and September 2015, the acetabular abduction and anteversion angles were measured in 50 patients undergoing THA. There were 24 males and 26 females, aged 37 to 83 years (mean, 71 years). The left hip was involved in 22 cases and the right hip in 28 cases. Of 50 patients, 34 suffered from fracture of the femoral neck, and 16 suffered from avascular necrosis of the femoral head. Acetabular dysplasia was excluded in all cases. A smartphone was used to measure the acetabular abduction and anteversion angles during operation; standard Picture Archiving and Communication Systems (PACS) was used to measured the acetabular abduction and anteversion angles on the X-ray film at 1 week after operation. It was defined as positive that the component angle values by PACS measurement were greater than those by the smartphone measurement, whereas as negative. The two measurement methods were compared, and intra-observer variability was assessed by analyzing the intraclass correlation coefficient (ICC), the Mann-Whitney U-test was used to analyze difference. ResultsThe ICC was 0.84 in the acetabular component angles by smartphone and PACS measurement methods. The acetabular component abduction angle was (44.02±1.33)° and the anteversion angle was (17.62±2.20)° by smartphone measurement. The acetabular component abduction angle was (44.74±4.05)° and the anteversion angle was (17.22±5.57)° by PACS measurement. There was no significant difference between two measurement methods (Z=-1.977, P=0.482; Z=-0.368, P=0.713). The acetabular component angle was in the safe zone in 44 cases; and the acetabular component anteversion angle was beyond safe range of 1 to 5°, and the abduction angle was beyond safe range of 1 to 3° in 6 cases. Intra-measurement variability was -21 to +10° for the anteversion angle and -10 to + 9° for the abduction angle, indicating that the acetabular component anteversion angle by smartphone measurement was greater than that by the PACS measurement, and the abduction angle was less than that by PACS measurement. ConclusionSmartphone is a convenient tool to measure the acetabular component angle in THA.
ObjectiveTo explore advantages and feasibility of a new prosthesis implantation method after breast cancer surgery by reacquaint breast anatomy. MethodsThe clinicopathologic data of patients with breast cancer were retrospectively collected. The patients underwent the breast cancer surgery and prosthesis implantation with cricoid breast ligament in the Xuzhou Cancer Hospital from January 1, 2021 to May 30, 2023. ResultsA total of 10 patients were collected, with age ranging from 31 to 59 years old. Three patients received postoperative analgesia, 2 patients occurred infection, 1 patient occurred fat liquefaction. All patients did not experience capsular contracture, flap necrosis, or removal of the prosthesis. Two patients had sentinel lymph node metastasis. All patients followed-up 3 to 24 months after surgery. The BREAST-Q questionnaire was used to assess the quality of life and satisfaction after surgery, 3 patients were very satisfied, 5 were satisfied, and 2 were basically satisfied. ConclusionFrom the results of limited cases analysis in this study, it is safe and feasible to implant the prosthesis with cricoid breast ligament in selected patients after breast cancer surgery.
Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.