  • PRELIMINARY EXPERIENCES IN MINIMALLY INVASIVE AND MINIINCISION SURGERY TOTAL HIP ARTHROPLASTY FOR LATE OSTEONECROSIS OF THE FEMORAL HEAD

    Objective To explore the effect of minimally invasive and mini-incision surgery (MIS) in total hip arthroplasty (THA) on late osteonecrosis of femoral head (ONFH). Methods From March 2003, Eighteen patients (22 hips) with ONFH underwent MIS in THA. Their ages ranged from 24to 57 years, including 13 males and 5 females. The mean body mass index ranged from 17.1 to 30.1(24.6 on average). The Harris hip score was 46 points before operation. Modified posterior-lateral approach was adopted, and the MIS THA was performed by cementless prosthesis. As a comparison, 18 patients (22 hips) were performed by conventional THA at the same period. The data, including bleeding volume during operation, incision length, operative time, and postoperative function recovery, were compared. Results Follow-ups were done for 6 to 20 months (11 months on average). Dislocation occurred in one patient that underwent conventional THA 2 days after operation. No complication occurred in MIS THA group. The incision lengths ranged from 8.7 to 10.5 cm (9.3 cm on average) in MIS THA group, being statistically different (Plt;0.01). There was no significant difference in Harris scoring of the function between the two groups both before the operation and after the operation (Pgt;0.05). The operative time was almost the same, but the bleeding volume in MIS THA group was less (Plt;0.05). The function recovery was faster in MIS THA group.Conclusion The MIS THA is an alternative to the treatment of late ONFH. The advantages of MIS THA are fewer trauma, less bleeding volume, and faster recovery. The MIS THA should be performed by surgeons with rich experiences in THA and hospitals with necessary instruments. 

    Release date:2016-09-01 09:30 Export PDF Favorites Scan
  • 人工全髋关节置换术中假体即刻翻修处理

    【摘 要】 目的 总结人工全髋关节置换术中假体即刻翻修的原因和处理经验,为临床提供参考。 方 法 1996 年5 月- 2005 年5 月,对行全髋关节置换的9 例患者行假体即刻翻修术。其中男5 例,女4 例;年龄51 ~ 73 岁。病因:股骨头缺血坏死4 例,股骨颈头下型骨折移位2 例,髋关节融合1 例,人工假体松动下沉2 例。术前Harris 评分为(39.6 ±8.4)分。行假体即刻翻修的原因:假体周围骨折4 例,股骨假体因骨水泥异常凝固未放置到位2 例,髋臼杯位置错误3 例。 结 果 手术时间3 ~ 6 h,平均4.5 h;术中出血600 ~ 1 400 mL,平均920 mL。伤口均Ⅰ期愈合,住院时间15 ~ 30 d,平均21 d。术后并发症:局部血肿2 例,髋关节脱位1 例,肺部感染2 例。9 例均获随访2 ~ 10 年,平均5.1 年。股骨假体周围骨折均愈合,未发生脱位和再翻修手术。术后Harris 评分为(89.3 ± 3.7)分,与术前比较差异有统计学意义(P lt;0.05)。 结论 术中即刻翻修应谨慎,根据具体情况,可采取更换加长柄股骨假体、股骨远端周围钢丝捆扎或记忆合金抱骨器,以及植骨和调整髋臼杯位置等方法。

    Release date:2016-09-01 09:09 Export PDF Favorites Scan
  • TOTAL HIP ARTHROPLASTY FOR THE TREATMENT OF DEVELOPMENTAL DYSPLASIA OF THE HIP IN ADULTS

    【Abstract】 Objective To summarize techniques of the total hi p arthroplasty (THA) in the treatment of developmental dysplasia of the hi p (DDH) with severe osteoarthritis in adults. Methods From March 2000 to January 2006, 24 patients (27 hips) with DDH were treated by THA with an cementless cup. There were 7 males and 17 females, withthe average age of 49.6 years (ranging from 26 years to 63 years). Unilateral DDH occurred in 21 patients and bilateral DDH occurred in 3 patients. Based on the Crowe classification, there were 16 hips in 15 patients of type I, 4 hips in 4 patients of type II, 4 hips in 3 patients of type III, 3 hips in 2 patients of type IV. Except for 3 patients with bilateral DDH, the other patients’ ill lower l imbs were 2-7 cm shorter than the healthy lower ones. Results All the patients were followed up from 9 months to 6.5 years and no one had infection, dislocation, femur fracture and so on after the operation. In 18 patients, the pain was completely rel ieved and the function of the hip joints was good. After the gluteus medius exercise, the claudication of 3 patients after the operation disappeared. In 3 patients, the ill lower l imbs were more than 1 cm shorter than the healthy lower ones and the other patients’ ill lower l imbs were less than 1 cm shorter than the healthy lower ones. Two patients’ lower l imbs were been lengthened 4-5 cm. All the patients’ sciatic nerves were not injured. The Harris scores were 46.5 ± 7.2 preoperatively and 84.0 ± 5.7 postoperatively (P lt; 0.05). Conclusion THA with deepening the medial wall of the acetabulum at the true acetabulum and choosing small cementless cup in adult could obtain favorable results.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • THE BALANCE OF THE LOWER LIMB LENGTHS IN THE TOTAL HIP ARTHROPLASTY

    Objective To investigate clinical significanceand surgical protocols about the balance of the lower limb lengths in the total hip arthroplasty. Methods Forty-eight patients undergoing the unilateral primary total hip arthroplasty from March 2000 to October 2004 were retrospectively studied. In 12 hips, the prostheses were of the cement type; in 36 hips, of the mixture type. Thirty patients with an equal limb length had a fractured femoral neck, 10 patients had a shortened (1.0-2.0 cm) limb, 6 patients had a shortened (2.0-4.0 cm)limb, and 2 patients had a shortened (4.0-6.0 cm) limb. Based on the clinical measurement and radiographic examination, the surgical protocols were designed, the hip prosthesis type was chosen, and the neck length of the femoral prosthesis and the position of osteotomy were estimated. By the wearing of the acetabula properly, the best rotation point was found out during the operation. The cut plane of the femoral neck was adjusted according to the results of the radiographic and other examinations. The neck length was readjusted after the insertion of the prosthesis so as to achieve an intended limblength equalization. Results All the patients were followed up for 3-42 months.According to the Harris scoring system, clinical results were excellent in 30 patients, good in 12, fair in4, and poor in 2. Of the 30 patients with an equal limb before operation, 5 were lengthened 1.0-2.0 cm in their lower limbs, and 1 lengthened 2.5 cm postoperatively. Of the 18 patients with shortened limbs before operation, 10 returned to the same lengths in their lower limbs, 6 were lengthened 1.0-2.0 cm in their lower limbs, but 2 with seriously-shortened lower limbs for congenital dysplasia of the hipjoint were still shortened 2.0-3.0 cm in the limb length after operation. The Harris hip scores revealed an average of 92.3 points in the patients with an equal limb length, and 88.6 points in the patients with shortened limbs. 〖WTHZ〗Conclusion Many factors, such as surgical protocols, prosthesis type designs, and the management techniques during the operation, can affect the limb length after operation. As the limb length discrepancy will make the patients feel disappointed, the clinical measurements are very important before operation. Application of the comprehensive appraisal methods during the operation, use of the soft tissuebalance method, and skills for obtaining an equal limb length during the total hip arthroplasty are also important for improving the surgical result further.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • ARTIFICIAL TOTAL HIP ARTHROPLASTY WITH COLLUM FEMORIS PRESERVING FOR TREATING HIP JOINT DISEASE IN YOUNG AND MIDDLE-AGED PATIENTS

    Objective To evaluate the therapeutic outcome of artificial total hip arthroplasty (THA) with collum femoris preserving for hip joint desease in young and middle-aged patients. Methods From March 2002 to March 2005, 26 cases (31 hips) of hip joint disease were treated with artificial THA with collum femoris preserving, including 19 males (23 hips)and 7 females (8 hips) and aged 32-48 years with an average of 37 years. In 31 hips, 17 left hips and 14 right hips were involved. There were 9 cases of osteoarthritis of the hip joint caused by avascular necrosis of the femoral head (ANFH), 7 cases of ANFH, 3 cases of femoral head necrosis caused by dysplasia of acetabular, 1 case of osteoarthritis of the hip joint caused by ankylosing spondyl itis, and 2 cases of rheumatoid arthritis; the course of disease was 2-11 years (5.6 years on average). Two cases of femoral neck fracture (Garden IV), and 2 cases of non-union femoral neck fractures (1 for Garden III and 1 for Garden IV), the course of disease was 5 days, 24 months, and 26 months. The prime symptoms were pain, difficult walk and l imp. All patients were taken X-ray to exclude osteoporosis. Results The right distal femur prosthesis of a bilateral patient cracked owing to excessive amputation of collum femoris, and fracture healed after symptomatic treatment. All the incisions healed by first intention and no compl ications occurred. All patients were followed up for 4-7 years, with an average of 5.6 years. One case had poor hip function because he did not follow rehabil itation procedure, and the others achieved good outcome with normal gait. One case complained of persistent pain 6 months after operation, and was rel ieved by administration of some non-steroidal antiinflammatory drugs and anti-osteoporosis drugs 6 months later. The X-ray films after operation and at last follow up showed good location of prosthesis and no bone resorption. Harris score at last follow-up was 91.31 ± 0.77, and it was significantly higher than that before operation (50.88 ± 0.90), (P lt; 0.05). The excellent and good rate was 93.5% (excellent in 11 hips, good in 18 hips, and fair in 2 hips). Conclusion Artificial THA with collum femoris preserving can retain more bone, be easier for revision, and has an excellent outcome.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • USE OF SMARTPHONE IN ACETABULAR COMPONENT ANGLE MEASUREMENT DURING TOTAL HIP ARTHROPLASTY

    ObjectiveTo evaluate the accuracy of using smartphone to measure the angle of acetabular component in total hip arthroplasty (THA). MethodsBetween June 2012 and September 2015, the acetabular abduction and anteversion angles were measured in 50 patients undergoing THA. There were 24 males and 26 females, aged 37 to 83 years (mean, 71 years). The left hip was involved in 22 cases and the right hip in 28 cases. Of 50 patients, 34 suffered from fracture of the femoral neck, and 16 suffered from avascular necrosis of the femoral head. Acetabular dysplasia was excluded in all cases. A smartphone was used to measure the acetabular abduction and anteversion angles during operation; standard Picture Archiving and Communication Systems (PACS) was used to measured the acetabular abduction and anteversion angles on the X-ray film at 1 week after operation. It was defined as positive that the component angle values by PACS measurement were greater than those by the smartphone measurement, whereas as negative. The two measurement methods were compared, and intra-observer variability was assessed by analyzing the intraclass correlation coefficient (ICC), the Mann-Whitney U-test was used to analyze difference. ResultsThe ICC was 0.84 in the acetabular component angles by smartphone and PACS measurement methods. The acetabular component abduction angle was (44.02±1.33)° and the anteversion angle was (17.62±2.20)° by smartphone measurement. The acetabular component abduction angle was (44.74±4.05)° and the anteversion angle was (17.22±5.57)° by PACS measurement. There was no significant difference between two measurement methods (Z=-1.977, P=0.482; Z=-0.368, P=0.713). The acetabular component angle was in the safe zone in 44 cases; and the acetabular component anteversion angle was beyond safe range of 1 to 5°, and the abduction angle was beyond safe range of 1 to 3° in 6 cases. Intra-measurement variability was -21 to +10° for the anteversion angle and -10 to + 9° for the abduction angle, indicating that the acetabular component anteversion angle by smartphone measurement was greater than that by the PACS measurement, and the abduction angle was less than that by PACS measurement. ConclusionSmartphone is a convenient tool to measure the acetabular component angle in THA.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
  • SIMULTANEOUS BILATERAL TOTAL HIP ARTHROPLASTY IN A SINGLE PROCEDURE

    Objective To study the effect of simultaneous bilateral total hip arthroplasty in a single procedure. Methods From October 1999 to March 2004, 15 patients (30 hips) underwent simultaneous sequential bilateral total hip arthroplasty (THAs) in a single procedure. Of the 15 patients, 11 were male (22 hips) and 4 were female (8 hips). Their ages ranged from 35 to 70 years. Their courses of disease ranged from 1 year to 50 years (4.8 years on average). The Harris scores of the joint function before the operation ranged from 12 to 45 points (27 points on average). Five were done with Smith-Peterson and 10 were done with Moore. Results The operative time was 3 hours and 25 minutes to 5 hours (4 hours and 10 minutes on average). The volume of blood transfusion during operation was 400 to 2 400 ml (1 160 mlon average). All the 15 patients were followed up for 3 to 35 months (18 monthson average). The Harris scores of the joint function after the operation rangedfrom 70 to 100 points (86 points on average). There was significant difference in the scores between before and after operations (Plt;0.05). There was only 1death within 1 months of the operation and no serious between complications such as infection, pulmonary embolism, and deep vein plug. All the patients were still ambulant in the community and gained significant pain relief. Conclusion Simultaneous bilateral total hip arthroplasty in a single procedure is a safe and effective method. However, the decision of performing singlestage bilateral total hip arthroplasty should be carefully made and preoperative preparation should be sufficiently made. 

    Release date:2016-09-01 09:30 Export PDF Favorites Scan
  • Comparison of filling ratio, alignment, and stability between ABGⅡ short-stem and Corail long-stem in total hip arthroplasty for Dorr type C femur

    Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • Mid-term effectiveness of total hip arthroplasty by direct anterior approach

    ObjectiveTo retrospectively compare the mid-term effectiveness between by direct anterior approach (DAA) and by posterolateral approach in total hip arthroplasty (THA).MethodsBetween January 2009 and December 2010, 110 patients (110 hips) treated with THA and followed up more than 5 years were chosen in the study. THA was performed on 55 patients by DAA (DAA group), and on 55 patients by posterolateral approach (PL group). There was no significant difference in gender, age, body mass index, types of hip joint disease, and preoperative Harris score between 2 groups (P>0.05). The operation time, amount of bleeding, length of hospital stay, postoperative complications, and the Harris scores were recorded and compared.ResultsThere was no significant difference in operation time and length of hospital stay between 2 groups (t=0.145, P=0.876; t=1.305, P=0.093). The amount of bleeding was significantly less in DAA group than in PL group (t=2.314, P=0.032). All patients were followed up 5-7 years (mean, 5.97 years). Complications happened in 5 cases (9.1%) of DAA group and in 3 cases (5.5%) of PL group, and there was no significant difference in the incidence of complications between 2 groups (χ2=0.539, P=0.463). There was significant difference in Harris scores at 6 months after operation between 2 groups (t=2.296, P=0.014), but no significant difference was found in Harris score at 1 year and 5 years between 2 groups (t=1.375, P=0.130; t=0.905, P=0.087). Further analysis, at 6 months after operation, the joint function score in DAA group was significantly higher than that in PL group (t=1.087, P=0.034), while there was no significant difference in the pain score and range of motion score between 2 groups (t=1.872, P=0.760; t=1.059, P=0.091).ConclusionTHA by DAA has the advantages of less bleeding and faster recovery. The short-term effectiveness is superior to the THA by traditional posterolateral approach, but there is no obvious advantage in the mid-term effectiveness.

    Release date:2017-09-07 10:34 Export PDF Favorites Scan
  • EFFECT OF MORPHOLOGICAL CHANGES IN PROXIMAL FEMUR ON PROTHESIS SELECTION OF TOTAL HIP ARTHROPLASTY IN PATIENTS WITH ANKYLOSING SPONDYLITIS

    Objective To investigate the effect of the morphological changes in the proximal femur on the prothesis selection in the total hip arthroplasty in the patients with ankylosing spondylitis. Methods The experimental group was composed of 13 patients (16 hips) with ankylosing spondylitis, which was treated with the total hip arthroplasty, and the control group was composed of 16 patients(19 hips)with non-ankylosing spondylitis,which was also treated with the total hip arthroplasty. In the two groups, the measurements of Singh index,canal flare index,morphological index of the cortex and cortical index were performed in the two groups. Results The results of the statistical analysis on Singh index,canal flare index, morphological index of the cortex and cortical index in the experimental group were 3.81±0.54, 2.63±0.41, 2.02±0.38 and 1.69±0.69, respectively, but 4.63±0.62, 3.03±0.27, 2.76±0.28 and 2.12±0.24, respectively in the control group. Therewas a significant difference in Singh index, canal flare index, and morphological index of the cortex between the two groups (Plt;0.05),while there was no statistical difference in cortical index between the two groups (P>0.05). The patientswith ankylosing spondylitis had more serious osteoporosis in their proximal femur. Conclusion Cemented femoral prosthesis should be used in the total hip replacement in patients with ankylosing spondylitis, and the revision total hip arthroplasty should be performed on patients with more serious osteoporosis.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan