find Author "兰琳" 3 results
  • 超声引导下乳腺穿刺活检的护理配合

    目的 总结彩色多普勒超声引导下乳腺穿刺活检的护理配合方法与体会。 方法 对2010年1月-3月超声引导下行乳腺穿刺活检的159例患者的护理资料进行回顾性分析,并就乳腺穿刺活检过程的护理配合要点予以概括。 结果 159例患者均一次性顺利完成穿刺,活检成功率100%,除1例活检中发生弥漫性巨大血肿外、其余患者均未发生感染、麻醉过敏、休克等并发症。 结论 超声引导下乳腺穿刺活检是一种安全可靠的微创手术方法,具有较高的临床价值,而护理配合是确保穿刺活检顺利进行的必要条件。

    Release date:2016-09-08 09:16 Export PDF Favorites Scan
  • Application of Ultrasound-guided Wire Localization in Surgical Excision of Non-palpable Breast Lesions

    【摘要】 目的 探讨超声引导下导丝定位在不可触及的乳腺病灶切除中的应用价值。 方法 对2005年1月-2010年9月127例女性患者的137个乳腺病灶(临床扪诊均为阴性),在超声引导下进行导丝定位,后进行外科切除活检,并对相关资料进行回顾性分析。 结果 137个病灶的组织学结果中,良性病灶101个(73.7%)、高风险病灶27个(19.7%)和癌9个(6.6%)。9个癌中3个为导管原位癌,6个为浸润性导管癌(大小11~19 mm,平均14.2 mm)。超声引导下导丝定位的时间为3~15 min,平均6 min;无血肿、导丝脱落及折断等并发症发生。外科手术切除时间20~40 min,平均30 min。 结论 超声引导下进行导丝定位安全、迅速,能协助外科手术进行准确的活检和切除。【Abstract】 Objective To determine the application value of ultrasound-guided wire localization in surgical excision of non-palpable breast lesions. Methods Between January 2005 and September 2010, 127 women with 137 non-palpable breast lesions underwent surgical excision at West China Hospital. Palpation results for all the lesions were negative. Wire localization guided by ultrasound was performed before operation and biopsy. Related imaging studies and medical records were reviewed retrospectively. Results Histological findings showed there were 101 benign lesions (73.7%), 27 high-risk lesions (19.7%), and 9 carcinomas (6.6%). Among the 9 carcinomas, 3 were ductal carcinoma in situ, and 6 were infiltrating carcinoma (with their size ranged from 11 to 19 mm averaging at 14.2 mm). The time of performing ultrasound-guided wire localization was from 3 to 15 minutes averaging at 6. No complications like hematoma, wire fragments, and wire breakage occurred in all cases. The surgical excision time ranged from 20 to 40 minutes averaging at 30. Conclusions Ultrasound-guided wire localization can be performed quickly and safely for the cases of non-palpable breast lesions. It is useful in assisting surgical excision and biopsy.

    Release date:2016-09-08 09:26 Export PDF Favorites Scan
  • Effect on Efficiency of Thyroid Nodules' Size for Ultrasound-Guided Fine-Needle Aspiration Biopsy

    ObjectiveTo assess the effect of the size of thyroid nodules on the diagnostic rate of ultrasound guided aspiration cytology (US-FNAB). MethodsThe data of 1 142 (performed by two doctors, 571 each) thyroid nodules between March 2011 and April 2014 in our hospital were retrospectively analyzed. Yields of US-FNAB were divided into two levels of adequacy and inadequacy according to the classification standard of the Bethesda system. The thyroid nodules were classified into five groups according to the largest diameter:≤5 mm group, 5-10 mm group,10-20 mm group, 20-30 mm group, and <30 mm group. According to the grouping of the nodules and the efficiency of US-FNAB drawed curve, the adequacy rates of alone and total of two examiners in each group were analyzed, respectively. ResultsThe adequacy rates of US-FNAB of alone and total of two examiners in≤5 mm group, 5-10 mm group,10-20 mm group, 20-30 mm group, and <30 mm group was 68.42%, 83.72%, 86.08%, 84.62%, and 73.53% (examiner 1); 68.75%, 70.53%, 81.05%, 86.15%, and 73.91% (examiner 2); 68.59%, 77.53%, 83.59%, 85.47%, and 73.75% (total of two examiners), respectively. The total adequacy rate of US-FNAB of two examiners in≤5 mm group was lower than that in 10-20 mm group (P<0.001) and 20-30 mm group (P=0.001). The adequacy rate of US-FNAB of examiner 1 in 5-10 mm group was higher than that examiner 2 (P=0.001). ConclusionsThe size of thyroid nodules significantly influences the adequate diagnostic rate of US-FNAB. The adequacy rates of US-FNAB of the largest diameter≤5 mm or <3mm were lower. The low adequacy rate of US-FNAB may be associated with cystic degeneration in the larger nodules.

    Release date: Export PDF Favorites Scan