west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "共焦" 17 results
  • Reproducibility of Heidelberg retinal tomograph measuring the macular retinal thickness

    ObjectivesTo evaluate the reproducibility of Heidelberg retina tomograph (HRT) macular edema module(MEM) measuring the macular retinal thickness.MethodsSixty-two healthy volunteers (9-68 years old) were examined by HRT-II procedure. The retinal signal width (SW) at macula and fovea and macular edema index (E) were recorded for t-test, Pearson linear-correlation analysis. Intra-subject variation repeatedly measured was analyzed with coefficient of variation, 95% tolerance limits of change (TC), and intraclass coefficient of correlation (ICC). ResultsIn healthy individuals, retinal SW was (0.734±0.236) mm at macula,and (0.781±0.243) mm at fovea; macular E was (1.169±0.619). The coefficient of variation repeatedly measured: retinal SW was (8.7±68)%,retinal SW at the fovea was (8.5±6.7)%, and the average was (15.6±13.9)%; 95%TC of intra-subject sequential repeated measurement was 0.131 (8.9%) of retinal SW, 0.137 (10.5%)of fovea SW,and 0.198 (7.4%) of average E. ICC of one individual repeatedly measured by one operator was 0.950 of macular SW, 0.949 of fovea SW, and 0.898 of average edema index.ConclusionsHRT-II MEM is noninvasive, fast and highly reproducible, which provides a new technique to monitor the objective quantification of macular diseases related to retinal thickness. ( Chin J Ocul Fundus Dis, 2005,21:103-105)

    Release date:2016-09-02 05:52 Export PDF Favorites Scan
  • Comparison of confocal laser scanning colorful fundus imaging and color fundus photography for detection of diabetic retinopathy

    ObjectiveTo compare the imaging characteristics and detection of various types of lesions in diabetic retinopathy (DR) with colorful laser scanning fundus imaging (MSLI) and traditional color fundus photography (CFP).MethodsProspective case series observational study. A total of 38 eyes of 38 patients with DR diagnosed by clinical examination were included in the study. Among them, 21 were male and 17 were female; the mean age was 62.6±11.2 years; the average duration of diabetes was 14.3±7.5 years. All the patients were performed CFP, MSLI, frequency domain optical coherence tomography (SD-OCT), fluorescein angiography (FFA) examination. Using the Helielberg Spectralis HRA+OCT MSLI inspection, one scan simultaneously obtained 488 nm blue reflection (BR), 515 nm green light reflection (GR), 820 nm infrared light reflection (IR), and multicolor image (MC). The detection of traditional CFP and MC on microaneurysm (MA), hard exudation (HEX), cotton plaque (CWS), intraretinal hemorrhage (IRH), intraretinal microvascular abnormality (IRMA), venous bead (VB), venous ring (VL), macular edema (DME), macular anterior membrane (MEM) and laser photocoagulation (LB) were comparatively observed. The results of FFA examination were used as the diagnostic criteria for lesions. SD-OCT was used to determine the location and depth of lesions and the diagnostic reference for DME and MEM.ResultsThe numbers of eyes with MA (χ2=10.460), DME (χ2=4.006), MEM (χ2=4.444) was significantly higher in MC than that of traditional CFP. But the number of eyes with IRH (χ2=0.103), CWS (χ2=1.515), HEX (χ2=0.227), IRMA (χ2=0.051), VB (χ2=0.001), VL (χ2=0.149), VH (χ2=0.693) and LB (χ2=0.720) were not statistically significant between two methods (P>0.05). The imaging quality of MSLI mode is obviously better than that of traditional CFP. Among them, GR imaging shows the best structural changes of superficial retina in MA, CWS, HEX, MEM, etc. IR imaging shows clear depth in deep retina such as LB. DME was green on MC and the weak low-reflection dark area was visible on the IR image, which were consistent with the DME range indicated by the SD-OCT examination.ConclusionsCompared with the traditional CFP, the MSLI can clearly show the DR lesion. The number of checkouts is high on MA, DME and MEM by MC image.

    Release date:2018-07-23 04:02 Export PDF Favorites Scan
  • Morphological assessment of macular hole surgery by scanning laser tomography

    Purpose To explore the role of scanning laser tomography in the assessment of macular hole surgery. Methods Fifteen eyes of 14 patients with macular holes underwent scanning of their affected macular area using the Heidelberg retina tomograph (HRT). The significance of topographic changes postoperatively were determined in eleven eyes which received vitrectomy surgery. The scan field was set at 15°of the retina and the depth was set to 1.5 mm or 2.0 mm. All the measurements were taken for 3 times and the average value of the 3 measurements was used. Results The average hole area was (0.499±0.34) mm 2 and the maximal depth of the hole was (0.284±0.11) mm. Topographic difference analysis of the eleven eyes showed a significant reduction in the height of the retina after vitrectomy. The maximal depth of the hole was (0.063±0.04) mm postoperatively. Conclusion Scanning laser tomography provides an objective evaluation of the anatomic outcome of the macular hole surgery. (Chin J Ocul Fundus Dis, 2002, 18: 125-127)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • The application of confocal scanning laser tomography in age-related macular degeneration

    Objective To verify the applicable significance of confocal scanning laser retinal tomography in agerelated macular degeneration (AMD). Methods Heidelberg confocal scanning laser tomography was used to measure 75 eyes of 59 patients with AMD, including 25 eyes of 20 patients with exudative AMD, 25 eyes of 16 patients with atrophic AMD, and 25 eyes of 23 patients with macular drusen. The differences of the width, volume and maximum height of Z profile signal of macula were analyzed. Results Z profile signal width in macular tomography of exudative AMD was wider than that of macular drusen; maximum height and volume in macular tomography of exudative AMD were larger than that of macular drusen (P<0.01); Z profile signal width, maximum height,and volume in macular tomography of atrophic AMD were wider and larger than that of macular drusen (P<0.05). Macular volume of exudative AMD was obviously larger than that of atrophic AMD (P<0.01). Conclusion Confocal scanning laser tomography may be one of the useful methods for objective evaluation of morphologic change for the development of AMD. (Chin J Ocul Fundus Dis, 2002, 18: 262-265)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • 海德堡视网膜断层扫描仪在青光眼诊断中的应用

    视盘形态学改变是青光眼早期征象,可出现在视野缺损之前。青光眼视盘改变主要表现有视网膜神经纤维层受损、盘沿面积的缩小和杯形的改变等。海德堡视网膜断层扫描仪检查可及时、无创伤地获得视盘三维图像,并可定量分析和随访青光眼视盘改变。现介绍其原理及在青光眼诊断和随访中的应用。 (中华眼底病杂志, 2002, 18: 250-252)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • The anatomical investigation of foveal avascular area

    Objective To observe the dimensions of the capillary blood vessel arch in central fovea of macula and the foveal avascular area (FAZ), and their relationships with age.Methods Retina in macula of 32 cadavers eyes were isolated . Retinal vessels were immunostained by collagen type IV and examined by confocal laser scanning microscopy. The area and diameter of the FAZ were measured, and the relationship between FAZ and age was analysed. Results The parafoveolar capillary network was observed clearly by confocal laser scanning microscopy. The average area of the FAZ was (0.24±0.13) mm2, and the average diameter was (0.54±0.15) mm. The area and diameter of the FAZ did not show any correlation with age.Conclusions The parafoveolar capillary network could be observed by confocal laser scanning microscopy. The size of the FAZ does not change with age. The dimensions of the parafoveolar capillary network may not be influenced by age. (Chin J Ocul Fundus Dis,2003,19:73-75)

    Release date:2016-09-02 06:00 Export PDF Favorites Scan
  • The clinical applications of adaptive optics scanning laser ophthalmoscope

    Adaptive optics (AO) is a technique to improve the performance of optical systems by reducing the influence of optical aberrations. Combined with scanning laser ophthalmoscope (AOSLO), the aberration of human refractive system can be corrected. Thus, the resolution and quality of imaging can be greatly improved to the cellular level in vivo retina (such as photoreceptor, nerve fibers, vascular parietal cell), therefore the earlier changes of the diseases can be detected. At the same time, microstructure changes of retinal can also be observed during the follow-up of the disease. Due to inherent technical defects of AOSLO, its wide application in clinical practice is limited. With the continuous progress of AO technology and the further improvement of related software functions, the function of the system will become more stronger and will play a more and more important role in scientific research and clinic.

    Release date:2020-01-11 10:26 Export PDF Favorites Scan
  • Corneal nerve fiber damage in different stage of diabetic retinopathy patients with type 2 diabetes

    Objective To observe the corneal nerve fibres damage in different stage of diabetic retinopathy (DR) with type 2 diabetes. Methods A cross-sectional study. One hundred and twenty eyes of 120 patients with type 2 diabetes served as diabetes group. According to International Clinical Diabetic Retinopathy Disease Severity Scales (2002), diabetes patients were classified into 4 subgroups: patients without diabetic retinopathy (NDR), patients with mild or moderate non-proliferative diabetic retinopathy (mNPDR), patients with severe non-proliferative diabetic retinopathy (sNPDR) and patients with proliferative diabetic retinopathy (PDR), each subgroup has 30 eyes of 30 patients. Another 30 eyes of 30 healthy participants served as control group. All eyes were scanned with HRT3 in vivo corneal confocal microscopy. Images of sub-basal nerve plexus were quantified including nerve fiber length (NFL), nerve fiber density (NFD), nerve fiber branch density (NFB), and nerve tortuosity (NT). The correlations of corneal nerve fiber with age, duration of diabetes and glycated hemoglobin (HbA1c) were analyzed using Spearman correlation analysis. Results NFL, NFD and NFB were found to be significantly lower in diabetic patients (F=147.315, 142.586, 65.898;P=0.000, 0.000, 0.000), NT was significantly greater in diabetic patients (F=39.431,P=0.000), when compared to control group. In diabetic patients, NFL, NFD and NFB were gradually reduced with DR severity, NT was gradually increased with DR severity. While the difference of NFL, NFD, NFB, NT was not statistically significant between sNPDR and PDR subgroups (P>0.05), but was statistically significant between other subgroups (P<0.05). Spearman correlation analysis results showed that age (r=-0.071, -0.080, 0.001, 0.100;P=0.391, 0.328, 0.991, 0.224) and HbA1c (r=-0.109, -0.115, -0.126, 0.025;P=0.238, 0.211, 0.169, 0.781) had no correlation with NFL, NFD, NFB, NT. Duration of diabetes was negatively correlated with the NFL, NFD (r=-0.212, -0.264;P= 0.020, 0.004), positive correlated with NT (r=0.261,P=0.004), and had no correlation with NFB (r=-0.119,P=0.194). Conclusions Corneal nerve fiber loss and nerve tortuosity increased were found in patients with type 2 diabetes, and even without diabetic retinopathy. The progress of corneal neuropathy was correlated with the severity of DR, but it was not change significantly between sNPDR and PDR.

    Release date:2017-04-01 08:56 Export PDF Favorites Scan
  • The diagnostic value of multicolor scanning laser imaging combined with swept-source optical coherence tomography for lacquer cracks and myopia stretch lines of pathological myopia

    ObjectiveTo analyze the diagnostic value of multicolor scanning laser imaging (confocal scanning laser ophthalmoscopy, cSLO) combined with swept-source optical coherence tomography (SS-OCT) for lacquer cracks (LC) and myopia stretch lines (MSL) of pathological myopia.MethodsA observational study. A total of 83 eyes of 58 patients with pathological myopia were recruited from May 2017 to January 2018 in Department of Ophthalmology of The First People’s Hospital Affiliated to Shanghai Jiao Tong University. Among 58 patients, 20 were males (30 eyes) and 38 were females (53 eyes). The mean age was 50.65±12.02 (range from 24 to 70) years old; the average BCVA was 0.37±0.32; the average diopter was −11.38±4.96 D; and the average axial length was 28.91±2.15 mm. All participants underwent FFA and ICGA examination to obtain FFA, ICGA, infrared light reflection (IR) and autofluorescence (AF) images. SS-OCT was applied for scanning macular and optic disc at 9 mm × 9 mm range. cSLO was performed with macular as the center. All images were inspected carefully by three independent observers and the consistency test was detect. LC were diagnosed as hyperreflective line in FFA and hypofluorescent linear lesions in late ICGA. MSL were defined as both hypofluorescent linear lesions in FFA and late ICGA. The accuracy of each inspection item in the diagnosis of LC was detected. The optimal technique was applied with SS-OCT to further explore the detection rate of LC.ResultsThe intra-observer reproducibility was good to excellent for all measurements (Kappa=0.938, P<0.01). The positive detection rate of LC and MSL was highest in the standard images of cSLO (77.1%), followed by SS-OCT red free (73.1%), fundus photography (72.3%), IR (72.3%) and AF (49.4%). The cSLO was optimal in the test consistency (Kappa=0.520, P<0.01) and accuracy (the area under the receiver operating characteristic was 0.750). SS-OCT and cSLO were jointly applied to diagnosis of LC and MSL in high myopia. The positive detection rate of LC, MSL and LC+MSL were 91.7%, 91.2% and 93.3% respectively. The characteristics of LC in SS-OCT were irregularities and discontinuous of the RPE-Bruch membrane line, discontinuous inner ellipsoid zone, thinner choroid, an increased light penetrance into deeper tissues, and RPE fracture in severe cases. MSL was mainly manifested as RPE clumps, visible large choroidal vessels protruding and pushing the overlying RPE toward the vitreous.ConclusionsThe diagnosis rate of LC in pathological myopia by cSLO is 77.1%. The standard images of cSLO combined with SS-OCT can diagnose LC, MSL and LC+MSL at rates of 91.7%, 91.2% and 93.3% respectively.

    Release date:2019-11-19 09:24 Export PDF Favorites Scan
  • 孤立性视网膜星状细胞错构瘤多波长炫彩和光相干断层扫描血管成像观察一例

    Release date:2019-01-19 09:03 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content