Objective To summarize clinical outcomes of right ventricle-to-pulmonary artery shunt (Sano shunt)as the first stage palliative operation for patients with pulmonary atresia with ventricular septal defect (PA/VSD). Methods Between September 2009 and May 2011,17 PA/VSD patients underwent Sano shunt in Fu Wai Hospital. There were 10 male patients and 7 female patients with their median age of 9.7 (2.5-73.8) months and average weight of (8.3±3.4)kg. Preoperative McGoon ratio was 1.04±0.29 and Nakata index was (102.0±56.9) mm2/m2. Five children had severe intrapericardial left pulmonary aretery stenosis,11 patients had patent ductus arteriosus (PDA),and 1 patient had major aorto-pulmonary collateral arteries. Preoperative transcutaneous oxygen saturation (SpO2) was 72.6%±11.6%. Results All the patients received Sano shunt placement successfully. Eleven patients underwent concomitant PDA ligation,and 7 patients underwent concomitant left pulmonary artery plasty. The Sano shunts were constructed with glutaraldehyde-fixed autologous pericardium in 10 patients,fresh autologous pericardium in 1 patient and Gore-Tex graft in 6 patients. All the patients underwent reconstruction of the right ventricular outflow tract via the right ventricular incision. The average cardiopulmonary bypass time was (75.0±30.0) min. Postoperative SpO2 was 89.8%±5.3% and significantly higher than preoperative SpO2 (P<0.05). All the patients were discharged alive and followed up for (12.1±6.7) months. During follow-up,8 patients underwent angiography study whose McGoon ratio and Nakata index improved to 2.05±0.37 and (304.8±51.3) mm2/m2 respectively,both of which were significantly higher than preoperative values(P<0.05). Four patients successful underwent second stage total correction. Conclusion Sano shunt is a comparatively safe procedure as the first stage palliative operation for PA/VSD patients,and can significant improve their pulmonary artery growth.
Abstract:Objective To investigate clinical characteristics of patients with aortic valve disease and coronary artery disease (CAD), and improve the pertinence of clinical management. Methods Clinical data of 78 patients who were older than 50 years and underwent isolated aortic valve replacement (AVR) in General Hospital of Shenyang Command from January to October 2010. All the patients were divided into two groups according to whether they had CAD:20 patients with CAD in the CAD group, including 19 males and 1 female with their average age of 64.6±8.3 years, and 58 patients without CAD in the control group, including 28 males and 30 females with their average age of 58.7±6.2 years. Clinical characteristics of AVR patients with CAD were analyzed by one-way analysis of variance and multiple factor analysis. Results One-way analysis showed that the incidence of old age (P=0.000), male patients (P=0.004), diabetes (P=0.004), aortic regurgitation (P=0.034), valvular lesion (P=0.028), and postoperative mechanical ventilation time (P=0.008)of CAD group patients were significantly higher or longer than those of control group patients. Multiple factor analysis showed that independent clinical characteristics of AVR patients with CAD included male patients, old age, prolonged postoperative mechanical ventilation time, significantly decreased pulmonary arterial systolic pressure (PASP) at 6th postoperative month, and significant preoperative right ventricular diastolic dysfunction. Conclusion The screening age for possible CAD should be reasonably lowered if male patients with aortic valve disease have concomitant preoperative right ventricular diastolic dysfunction and/or tricuspid aortic valve degeneration. Patients undergoing isolated AVR need to take medications to reverse left ventricular remodeling for a long time to avoid severe arrhythmia.
Objective To assess clinical results of three different conduit materials (Gore-Tex synthetic graft,bovinejugular vein and autologous pericardium)for palliative right ventricle-to-pulmonary artery (RV-PA) shunt,and explore the correlation between suitable conduit size and patients’ body weight and McGoon ratio. Methods We retrospectively analyzed clinical data of 24 patients with congenital heart diseases who underwent palliative RV-PA shunt in Department of Pediatric Cardiovascular Surgery of Fu Wai Cardiovascular Hospital from July 2010 to July 2012. There were 11 males and 13 females with their age ranging from 60 days to 6 years and body weight of 10.22±7.41 kg. There were 22 patients with pulmonary atresia and ventricular septal defect (PAVSD),1 patient with tetralogy of Fallot (TOF) and 1 patient with doubleoutlet right ventricle (DORV). Among different conduit materials,autologous pericardium was used for 17 patients,Gore-Texsynthetic graft was used for 5 patients,and bovine jugular vein was used for 2 patients. Conduit size and children’s body weight were analyzed with linear regression,then the equation was corrected with McGoon ratio. Results There was no perioperative death. Postoperative percutaneous saturation (SpO2)of the 24 children was 20.37%±28.33% higher than preoperative SpO2 . Electrocardiogram showed sinus rhythm in all the patients. Twenty-three patients were NYHA classⅡ,and 1 patient was NYHA classⅢ. Postoperative mechanical ventilation time of patients with autologous pericardium were significantly shorter than those of patients with other 2 materials (P=0.017). Sixteen patients were followed up from 10 months to 2 years after discharge,including 12 patients with autologous pericardium,3 patients with Gore-Tex synthetic graft and 1 patient with bovine jugular vein. During follow-up,McGoon ratio of patients with autologous pericardium,Gore-Tex synthetic graft and bovine jugular vein were 1.98±0.46,1.83±0.33 and 1.68 respectively,all of which weresignificantly higher than preoperative McGoon ratio (P<0.05). Six patients underwent radical corrective surgery,including5 patients with autologous pericardium and 1 patient with Gore-Tex synthetic graft. There was no complication directly related to surgery during follow-up. Linear regression was performed to form an equation between suitable conduit size and patients’ body weight:conduit diameter (mm)=0.327×body weight (kg)+4.599. McGoon ratio,conduit size and equationresult were compared to find a practical choice of conduit size. If McGoon ratio<0.8,the first integer greater than the equation result could be chosen. If McGoon ratio>1.2,the first integer less than the equation result could be chosen. If 1.2>McGoon ratio>0.8,the first integer either less or greater than the equation result could be chosen. Group analysis showed that patients who recovered better postoperatively were those whose conduit sizes were closer to equation results as well as equation results corrected with McGoon ratio. Conclusion All the 3 materials can be conventionally chosen for RV-PA shunt. Appropriate conduit size can be decided upon patients’ body weight and McGoon ratio for RV-PA shunt.
Objective To evaluate early results of valved bovine jugular vein patch for reconstruction of the right ventricular outflow tract (RVOT).?Methods From May 2009 to March 2010, a total of 60 patients with complex congenital heart diseases underwent reconstruction of RVOT with valved bovine jugular vein patch in Wuhan Asia Heart Hospital. There were 42 males and 18 females with their mean age of 6.2±8.9 years (ranging from 5 months to 33 years) and mean body weight of 27.5±24.0 kg, and 34 patients were less than 1 year. Preoperative clinical diagnosis included tetralogy of Fallot (n=38) and double outlet of right ventricle with pulmonary stenosis (n=22). All the patients underwent one-stage surgical repair. Before operation, 4 patients underwent catheter intervention for their major aortopulmonary collaterals. The diameters of pulmonary arterial ring of all the patients were 2 standard deviation less than normal range, and trans-annular patch was chosen for RVOT reconstruction. All the patients were postoperatively followed up for 18 to 26 months (mean 21.2±4.6 months).?Results There was no in-hospital death. And no second surgical intervention was needed for conspicuous RVOT stenosis or pulmonary regurgitation. Three patients needed reintubation for lung edema after extubation as a result of major aortopulmonary collaterals. Four patients underwent reexploration for postoperative bleeding. And all the other patients were discharged uneventfully. Mean cardiopulmonary bypass time was 84.0±22.0 min, and mean aortic cross-clamping time was 42.0±12.0 min. Mean RVOT gradient right after surgery was 18.0±4.5 mm Hg, which was not statistically different from mean RVOT gradient of 19.2±5.4 mm Hg measured by transthoracic echocardiography at their last postoperative follow-up(P>0.05). The degree of pulmonary regurgitation right after surgery was trivial in 32 patients(1+), mild in 28 patients(2+), which were not statistically different from the degree of pulmonary regurgitation at their last postoperative follow-up: trivial in 28 patients (1+), mild in 27 patients(2+), and moderate in 5 patients(3+). Calcification was not observed on the valved bovine jugular vein patch and valve cusp, and the valve cusp motioned well. No thrombosis or endocarditis was observed on the valved bovine jugular vein.?Conclusions For patients with tetralogy of Fallot or double outlet of right ventricle (DORV) and pulmonary stenosis, valved bovine jugular vein patch is a good choice for trans-annular reconstruction of RVOT. There is no severe postoperative complication related to bovine jugular vein, the RVOT pressure gradient does not increase significantly, and anti-regurgitation result is satisfactory in short-term follow-up. Further follow-up is required to evaluate its long-term outcome.