  • 库存悬浮红细胞预处理对婴幼儿预充液中血糖、乳酸及钾离子的影响

    目的 观察库存悬浮红细胞预处理后对婴幼儿预充液中血糖、乳酸及钾离子浓度的影响,及对婴幼儿生理代谢的影响。 方法 2010年2月至2011年3月解放军第452医院收治40例先天性心脏病婴幼儿,按预充前是否清洗库存悬浮红细胞,将其分为两组,悬浮红细胞清洗组(清洗组,n=20):男11例,女9例;年龄(17.82±6.11)个月;在体外循环(CPB)中预充前采用血液回收机(cell saver)对库存悬浮红细胞进行清洗预处理;未清洗组(n=20):男6例,女14例;年龄(16.63±4.45)个月;在应用库存悬浮红细胞预充前未经清洗。两组在预充前(清洗组在库存悬浮红细胞清洗前、清洗后)、预充后、CPB前并行期、主动脉阻断后5 min、停机时分别检测血糖、血清乳酸和血钾离子浓度。 结果 清洗组库存悬浮红细胞清洗后血糖、乳酸和钾离子浓度明显低于清洗前(P<0.05)。在CPB各时间点清洗组血糖[主动脉阻断后5 min: (4.50±0.65) mmol/L vs. (5.78±0.62) mmol/L,t=5.308,P=0.001]和乳酸浓度 [主动脉阻断后5 min:(1.86±0.21) mmol/L vs. (2.89±0.45) mmol/L,t=1.504,P=0.001]明显低于未清洗组。除停机时,其余时间点清洗组钾离子浓度明显低于未清洗组 [主动脉阻断后5 min: (3.81±0.32) mmol/L vs. (4.44±0.51) mmol/L,t=3.588,P=0.011]。 结论 采用血液回收机(cell saver)清洗后的含库存悬浮红细胞预充液中的血糖、乳酸、钾离子浓度明显降低至生理范围内,可显著提高婴幼儿CPB的安全性。

    Release date:2016-08-30 05:45 Export PDF Favorites Scan
  • Effect of intraoperative autotransfusion on erythrocytes in coronary artery bypass grafting

    Objective To explore ability of deformation ,small deformation, orientation and in vivo half-life of erythrocytes following intraoperative autotransfusion by ZITI-3000 cell saving system (Jingjing medical facility corporation, Beijing). Methods Twenty consecutive patients undergoing scheduled off-pump coronary artery bypass grafting (CABG) were divided into two groups according to intraoperative autotransfusion, experimental group(n=10): intraoperative autotransfusion was performed; control group (n=10): intraoperative autotransfusion wasn’t used. Laser diffractometer was used to measure deformation index(DI), small deformation index[(DI)d.max], and orientation index [(DI)or.max],and chromium51 istope labeling technique was used to measure half-life of erythrocytes (51C1/2) of processed and unprocessed in vivo. Results There were no significant difference in DI, (DI)d.max, (DI)or.max and 51C1/2 in vivo between experimental group and control group. Conclusion Intraoperative autotransfusion has no significant effect on erythrocytes’s ability of DI, (DI)d.max, (DI)or.max and 51C1/2 in vivo in off-pump CABG.

    Release date:2016-08-30 06:28 Export PDF Favorites Scan
  • 术中自体血液回收对体外循环术后全身性炎性反应的影响

    目的 探讨在体外循环手术中使用洗涤式自体血液回收机(ATS)对术后全身性炎性反应的影响.方法 将择期体外循环冠状动脉旁路移植术(CABG)的12例患者随机分为两组(每组6例),实验组:将手术野渗血和停机后机血混合经ATS处理后回输;对照组:将停机后机血直接回输.于围手术期测定两组补体终末复合物(sC5b-9)、白细胞介素-6(IL-6)等炎性因子指标.实验组分别测定ATS处理前后炎性因子指标. 结果 实验组回收血经ATS处理后红细胞压积(HCT)明显升高(Plt;0.01),sC5b-9、肿瘤坏死因子-α(TNF-α)和IL-6水平显著降低(Plt;0.05).停机6小时、24小时和48小时,实验组sC5b-9变化率均低于对照组(Plt;0.05),停机48小时,实验组IL-6变化率低于对照组(Plt;0.05),术后两组TNF-α水平以及变化率差别无显著性意义;停机48小时,实验组中性粒细胞(PMN)显著低于对照组(Plt;0.01). 结论 在体外循环手术中使用ATS回收术野渗血和停机后机血可以去除绝大部分炎性介质,回输后可以降低术后部分炎性介质的水平,减轻体外循环术后的炎性反应.

    Release date:2016-08-30 06:32 Export PDF Favorites Scan
  • ASSESSMENT STUDY ON A SET OF PLATELET-RICH PLASMA PREPARATION

    Objective To calculate the recovery rate and enrichment factor and to analyse the correlation by measuring the concentrations of platelets, leukocyte, and growth factors in platelet-rich plasma (PRP) so as to evaluate the feasibil ity and stabil ity of a set of PRP preparation. Methods The peripheral blood (40 mL) was collected from 30 volunteers accorded with the inclusion criteria, and then 4 mL PRP was prepared using the package produced by Shandong Weigao Group Medical Polymer Company Limited. Automatic hematology analyzer was used to count the concentrations of platelets and leukocyte in whole blood and PRP. The enrichment factor and recovery rate of platelets or leukocyte were calculated; the platelet and leukocyte concentrations of male and female volunteers were measured, respectively. The concentrations of platelet-derived growth factor (PDGF), transforming growth factor β (TGF-β), and vascular endothel ial growth factor (VEGF) were assayed by ELISA. Results The platelet concentrations of whole blood and PRP were (131.40 ± 29.44) × 109/L and (819.47 ± 136.32) × 109/L, respectively, showing significant difference (t=—27.020, P=0.000). The recovery rate of platelets was 60.85% ± 8.97%, and the enrichment factor was 6.40 ± 1.06. The leukocyte concentrations of whole blood and PRP were (5.57 ± 1.91) × 1012/L and (32.20 ± 10.42) × 1012/L, respectively, showing significant difference (t=—13.780, P=0.000). The recovery rate of leukocyte was 58.30% ± 19.24%, and the enrichment factor was 6.10 ± 1.93. The concentrations of platelets and leukocyte in PRP were positively correlated with the platelet concentration (r=0.652, P=0.000) and leukocyte concentration (r=0.460, P=0.011) in whole blood. The concentrations of platelet and leukocyte in PRP between male and female were not significantly different (P gt; 0.05). The concentrations of PDGF, TGF-β, and VEGF in PRP were (698.15 ± 64.48), (681.36 ± 65.90), and (1 071.55 ± 106.04) ng/ mL,which were (5.67 ± 1.18), (6.99 ± 0.61), and (5.74 ± 0.83) times higher than those in the whole blood, respectively. PDGF concentration (r=0.832, P=0.020), TGF-β concentration (r=0.835, P=0.019), and VEGF concentration (r=0.824, P=0.023) in PRP were positively correlated with platelet concentration of PRP. Conclusion PRP with high concentrations of platelets, white blood cells and growth factors can be prepared stably by this package.

    Release date:2016-08-31 05:41 Export PDF Favorites Scan
  • Application of Autobloodtransfusion Technique During Operation on Massive Haemorrhage

    目的:探讨自体血液回收技术对循环、血细胞和凝血功能的影响及应用效果。方法: 选择急诊大失血手术患者27例,采用ZITI-2000型血液回收机回收血液,经过滤、离心、清洗后回输给患者。分不同时点观察HR、SBP、MAP、DBP、SPO2的变化,并监测RBC、Plt、HB、Hct、FIB、PT、APTT的变化。计算输血量和异体输血率。随机选择8例进行回收原血和回输 血血细胞学比较。结果:(1)术前血压较低,心率较快,回输血液后,HR显著降低(Plt;0.01),SBP和MAP显著升高(Plt;0.01)。(2)术前RBC、HB和Hct均低于正常水平,回输后各时点均升高明显(Plt;0.01)。术前FIB和Plt低于正常水平,回输后各时点增高,但无显著意义。PT、APTT无明显变化。(3)回收原血平均每例3735mL,回输血平均每例1589mL,异体输血率为25%。(4)回输血RBC、HB和Hct均显著高于回收原血(Plt;0.01)。结论:自体血液回收技术用于临床安全可靠,能有效维持循环的稳定,对凝血功能无明显影响,节约血源,减少异体输血。

    Release date:2016-09-08 10:02 Export PDF Favorites Scan
  • 数字图像及电子内标签在手术器械回收中的应用分析

    目的探讨数字图像及电子内标签在降低手术器械回收差错率、提升工作效率的效果。 方法建立并使用手术器械数字图像及电子内标签,将每套手术器械分类整理,用数码相机拍摄,留存数字图像并按照器械名称命名后存盘;用电子表格制作手术器械的内标签并存盘。存盘后的数字图像及手术器械内标签拷贝在手术器械回收点的电脑中,同时植入到手术器械信息追溯系统中。选择2013年1月-2014年12月在手术器械回收岗工作的普通工人,进行手术器械数字图像及电子内标签的操作培训。将建立手术器械数字图像及电子内标签前后1年,2013年1月-12月为A组,2014年1月-12月为B组。比较两组手术器械回收差错率、手术室满意度及回收操作人员满意度。 结果与建立手术器械数字图像及电子内标签前1年(A组,0.045%)比较,B组手术器械回收的差错率(0.007%)降低,而采用手术器械数字图像及电子内标签后回收操作人员对其便捷性、可操作性、操作意愿、操作准确性及岗位成就感的满意度均提高(P<0.05);手术室满意度从92%提高到100%。 结论数字图像和电子内标签能直观、形象的识别手术器械、特殊器械的重要部件,还能对照检查手术器械包的完整性,方便回收操作人员在回收时发现手术器械的缺失、损坏,及时与手术室沟通,将差错杜绝在源头,提高了工作准确度和满意度。

    Release date:2016-11-23 05:46 Export PDF Favorites Scan