In 2020, the American Association of Hip and Knee Surgeons (AAHKS), the American Society of Regional Anesthesia and Pain Medicine (ASRA), the American Academy of Orthopaedic Surgeons (AAOS), the American Hip Society (THS), the American Knee Society (TKS) have worked together to develop clinical practice guidelines on the use of Opioids in primary total joint arthroplasty (TJA). This clinical practice guideline formulates recommendations for common and important questions related to the efficacy and safety of Opioids in primary TJA. This article interprets the guideline to help doctors make clinical decisions.
ObjectiveTo compare the effectiveness between histoacryl topical skin adhesive and traditional method for wound closure in total hip arthroplasty (THA). MethodsA total of 159 patients undergoing THA were divided into 2 groups between January and October in 2015. Subcuticular suture and histoacryl topical skin adhesive (cyanoacrylate adhesive) were used in 80 patients (100 hips) (test group), and traditional method (skin staples and wound drainage) was used in 79 patients (100 hips) (control group) for wound closure. There was no significant difference (P > 0.05) in gender, age, body mass index, and etiology between 2 groups. The operation time, length of stay, incision pain visual analogue scale (VAS) score and healing of incision, and incision satisfaction evaluation, and classification were compared between 2 groups. ResultsAll patients were followed up 3-6 months (mean. 4.7 months). There was no significant difference in operation time between 2 groups (Z=-0.527, P=0.598); but the length of stay of test group was less than that of control group (Z=-2.004, P=0.045). Incision exudation and dehiscence occurred in 1 case (1 hip) and 1 case (1 hip) of test group respectively; incision swollen, persistent wound exudation, exudation, and sutured drainage tube occurred in 2 cases (2 hips), 2 cases (2 hips), 4 cases (4 hips), and 1 case (1 hip) of control group. No statistically significant difference was found in VAS score between 2 groups at 15 days after operation (Z=-0.125, P=0.901), but wound healing score of test group was significantly higher than that of control group (Z=-2.943, P=0.003). Wound healing was class A in 98 hips and class B in 2 hips in test group, and was class A in 92 hips and class B in 8 hips in control group, and difference was statistically significant (χ2=3.789, P=0.048). The incision satisfaction of test group was significantly higher than that of control group (Z=-2.626, P=0.009). ConclusionCompared with traditional method, histoacryl topical skin adhesive has decreased wound complication rate, and it is an easy and safe method with high satisfaction.
ObjectiveTo explore the safety and effectiveness of quadriceps snip in complex total knee arthroplasty (TKA).MethodsA clinical data of 19 cases (29 knees) with complex TKA assisted with quadriceps snip between January 2016 and May 2017 were retrospectively analyzed. There were 9 males (13 knees) and 10 females (16 knees). The age of patients ranged from 34 to 66 years (mean, 50.2 years). Four patients (8 knees) were ankylosing spondylitis, 5 patients (7 knees) were rheumatoid arthritis, and 10 patients (14 knees) were knee osteoarthritis. The average disease duration was 10.9 years (range, 8-15 years). There were 12 knees of Kellgren-Lawrence grade Ⅲ and 17 knees of Kellgren-Lawrence grade Ⅳ. The range of motion (ROM) of knee was (19.86±7.23)°. The clinical and function scores of knee society score (KSS) were 47.86±11.26 and 15.52±11.21, respectively. Postoperative complications, ROM, KSS scores, extensor lag, and prosthesis loosening were observed to evaluate the effectiveness.ResultsAll incisions healed by first intention, and no infection or cardiovascular and cerebrovascular accidents occurred. All patients were followed up 25-39 months (mean, 30.3 months). At last follow-up, the ROM of knee was (91.03±7.30) °, the KSS clinical score was 83.62±9.99 and functional score was 66.38±7.89, showing significant differences when compared with preoperative ones (P<0.05). Postoperative extensor lag (10°, 10°, 15°) occurred in 3 cases. There was no evidence of prosthesis loosening or osteolysis on X-ray films during follow-up.ConclusionThe application of quadriceps snip in complex TKA can effectively improve the operative field exposure and reduce incidence of complications such as patella tendon tearing, patella fracture, and quadriceps tendon injury. The surgical technique of Krackow tendon suture can effectively guarantee early rehabilitation without occurrence of other complications.
Objective To investigate the changes of low back pain (LBP) and spinal sagittal parameters in patients with unilateral Crowe type Ⅳ developmental dysplasia of the hip (DDH) after total hip arthroplasty (THA). Methods The clinical data of 30 patients who met the selection criteria between October 2018 and March 2020 were retrospectively analyzed. Patients were divided into LBP group (16 cases) and control group (14 cases) according to whether there was LBP before operation. There was no significant difference between the two groups of patients in gender, age, body mass index, affected sides, preoperative Harris score (P>0.05). Full-length lateral X-ray films of the spine were taken within 1 week before operation and at 1 year after operation, and the following imaging indicators were measured: sacral slope (SS), lumbar lordosis (LL ), spinal tilt (ST), spine-sacral angle (SSA), sagittal vertebral axis (SVA). The visual analogue scale (VAS) score, lumbar Oswestry disability index (ODI), the Harris score of the hip joint before operation and at 1 year after operation, and the occurrence of postoperative complications were collected and analysed. Results In the LBP group, LBP was relieved to varying degrees at 1 year after operation, of which 13 patients (81.3%) had complete LBP remission; VAS score decreased from 4.9±2.3 preoperatively to 0.3±0.8, ODI decreased from 33.5±22.6 preoperatively to 1.3±2.9, the differences were all significant (t=7.372, P=0.000; t=5.499, P=0.000). There was no new chronic LBP in the control group during follow-up. The Harris scores of the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference between the two groups at 1 year after operation (t=0.421, P=0.677). There was no significant difference in imaging indexes between the two groups before operation and the difference between pre- and post-operation (P>0.05). At 1 year after operation, ST and SVA in the LBP group, SSA in the control group, and SS in the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference in the other indexes between the two groups before and after operation (P>0.05). Conclusion Unilateral Crowe type Ⅳ DDH patients with LBP before operation were all relieved of LBP after THA. The relief of LBP may be related to the improvement of spinal balance, but not to lumbar lordosis and its changes.
Objective To investigate the effect of accuracy of phase 3 Oxford prosthesis positioning on short-term effectiveness of unicompartmental knee arthroplasty (UKA). Methods The clinical data of 26 patients (26 knees) who were treated with UKA between September 2015 and November 2015 was retrospectively analyzed. The single-peg Oxford prosthesis was implanted in 15 patients (single-peg group), and twin-peg Oxford prosthesis was implanted in 11 patients (twin-peg group). There was no significant difference in gender, age, body mass index, Kellgren-Lawrence grading, and preoperative Hospital for Special Surgery (HSS) scores between 2 groups (P>0.05). HSS, knee society score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and Oxford knee score (OKS) were used to evaluate the knee function. Radiographic criteria for Oxford UKA was used to evaluate the prosthesis position. The reason and treatment of bearing dislocations were recorded. Results All patients were followed up with mean follow-up time of 26.2 months in single-peg group (range, 24-27 months) and 25.2 months in twin-peg group (range, 24-26 months). The bearing dislocation occurred in 2 cases of twin-peg group during follow-up. At last follow-up, there was no significant difference in HSS, WOMAC, OKS, and KSS scores between 2 groups (P>0.05). There was no significant difference in radiographic scores of femoral component, tibial component, and overall components between 2 groups (P>0.05). No significant correlation was found between radiographic scores and postoperative functional outcome in 2 groups (P>0.05). Conclusion Within a safe range, the accuracy of phase 3 Oxford prosthesis positioning has limited influence on the short-term functional outcome.
ObjectiveTo summarize the clinical application and research progress in unicompartmental knee arthroplasty (UKA).MethodsThe literature related to UKA in recent years was reviewed and the emerging indications, implant options, comparisons between other surgical techniques, and recent advances were summarized.ResultsClinical studies show that UKA has many advantages, such as less trauma, faster recovery, and fewer postoperative complications. At present, the operative indication has been expanded. The body mass index more than 25 kg/m2, less than 60 years old, patellofemoral arthritis, and anterior cruciate ligament dysfunction are no longer considered as contraindications. The prosthesis type in UKA should be selected according to the patient’s condition. In recent years, the robot-assisted UKA can effectively improve the effectiveness, improve patient satisfaction, and reduce postoperative complications.ConclusionWith the development of surgical techniques, designs of prosthesis, and the robotic technology, UKA would be further applicated. As more long-term data on UKA become available, it will further guide clinicians in counseling patients on whether UKA should be performed.
Objective To evaluate the early effectiveness and summarize the initial application experiences of Mako robot-assisted total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) in adults. Methods Between August 2018 and January 2020, 55 cases of DDH (75 hips) were treated with Mako robot-assisted THA. There were 10 males and 45 females with an average age of 51 years (range, 30-73 years). There were 35 cases of unilateral hip and 20 cases of bilateral hips. The DDH was classified as Crowe type Ⅰin 29 hips, type Ⅱ in 20 hips, type Ⅲ in 6 hips, and type Ⅳ in 20 hips. The modified Harris score was 54.8±16.0, the hip joint range of motion was 90° (80°, 100°), and the leg length discrepancy (LLD) was 22.0 (10.5, 47.0) mm. The preoperative surgical plan was made in the robot system based on the CT data. The reaming and installation of the acetabular cup were completed with the assistance of the robot system. The distance between the rotation center of the hip joint and the teardrop (horizontal distance, vertical distance), inclination angle, and anteversion angle were measured on the pelvic X-ray film to evaluate the position of the acetabular prosthesis. The above indicators were compared with preoperative planning to evaluate the accuracy of robotic-assisted surgery. The modified Harris score, the range of motion, and the LLD were used to evaluate the early effectiveness. Results The 75 hips of THAs were completed with the assistance of Mako robots. There was no significant difference in the acetabular inclination angle, the horizontal distance and the vertical distance of the rotation center between the preoperative planning and the postoperative measurement values (P>0.05); the acetabular anteversion angle was significantly smaller than the postoperative measurement value (t=–2.482, P=0.015). Four hips located beyond the Lewinnek safety zone, and 71 hips located within the Lewinnek safety zone. All patients followed up 6-24 months (mean, 13 months). All incisions healed by first intention. At last follow-up, the modified Harris score was 85.5±11.2, the hip joint range of motion was 120° (110°, 120°), and the LLD was 3.8 (2.0, 8.1) mm; all improved significantly compared with preoperative ones (P<0.05). Except for one nerve injury case, there was no other complication. Conclusion Mako robot-assisted THA is a safe and effective method for adult DDH, which can optimize the acetabular cup positioning, hip function, and leg length, but the long-term effectiveness needs to be confirmed by further studies.
ObjectiveTo compare the effectiveness of three different fixation methods after subtrochanteric shortening osteotomy (SSO) in total hip arthroplasty (THA) for Crowe type Ⅳ developmental dysplasia of the hip (DDH). Methods A clinical data of 63 patients (78 hips) with Crowe type Ⅳ DDH, who underwent THA with SSO between November 2014 and May 2019, was retrospectively analyzed. Among them, 18 patients (20 hips) obtained stability by intramedullary pressure provided by the S-ROM modular prostheses (group A); 22 patients (30 hips) underwent prophylactic binding by stainless steel wire after osteotomy and before stem implantation (group B); 23 patients (28 hips) were fixed with autogenous cortical strut grafts and stainless steel wire or cables (group C). There was no significant difference in gender, age, body mass index, affected limb side, and preoperative Harris score between groups (P>0.05). The operation time, complications, imaging results, hip functional score of the three groups were recorded and compared. Results There was no significant difference in the operation time between groups (P>0.05). All incisions healed by first intention. All patients were followed up, and the follow-up time was 2.5-4.0 years (mean, 3.1 years) in group A, 1.5-5.5 years (mean, 3.2 years) in group B, and 1.0-5.0 years (mean, 1.6 years) in group C. There was no significant difference in Harris score or Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score between groups at 4 and 12 months after operation (P>0.05). X-ray films showed that there was no significant difference in osteotomy healing rate at 4, 8, and 12 months after operation and the osteotomy healing time between groups (P>0.05). There was no complications such as joint dislocation, prosthesis loosening, prosthetic joint infection, or heterotopic ossification during follow-up, except for the distal femoral fracture of 1 hip during operation in group B. Conclusion In THA for patients with Crowe type Ⅳ DDH, the stainless steel wire binding alone and autogenous cortical strut grafts combined with stainless steel wire or cable binding can not significantly promote the osteotomy healing compared with femoral prosthesis intramedullary compression fixation. For patients with nonmatched medullary cavity after SSO, it is recommended to apply autogenous cortical strut grafts with wire or cables for additional fixation.
ObjectiveTo evaluate the application and effectiveness of bilateral total hip arthroplasty and total knee arthroplasty in the treatment of severe inflammatory arthropathies. MethodsBetween September 2008 and September 2015, 31 patients with severe inflammatory arthropathies were treated with bilateral total hip arthroplasty and total knee arthroplasty. Of 31 cases, 22 were male and 9 were female with an average age of 30 years (range, 20 to 41 years); there were 15 cases of rheumatoid arthritis and 16 cases of ankylosing spondylitis with an average onset age of 14 years (range, 5-28 years); all 4 ankylosed joints were observed in 11 cases, 3 ankylosed joints in 2 cases, 2 ankylosed joints in 6 cases, 1 ankylosed joint in 1 case, and no ankylosed joint in 11 cases. Before operation, the hip range of motion (ROM) value was (17.82±28.18)°, and the knee ROM value score was (26.45±30.18)°; the hip Harris score was 29.64±11.58, and the hospital for special surgery (HSS) score was 27.07±11.04. The patients were grouped and compared in accordance with etiology and ankylosed joint. ResultsOne-stage arthroplasty was performed in 1 case, two-stage arthroplasty in 22 cases, three-stage arthroplasty in 7 cases, and four-stage arthroplasty in 1 case. The total operation time was 325-776 minutes; the total blood loss was 900-3 900 mL; the total transfusion volume was 2 220-8 070 mL; and the total hospitalization time was 21-65 days. The patients were followed up 12-94 months (mean, 51 months). The hip and knee ROM values, Harris score and HSS score at last follow-up were significantly improved when compared with preoperative ones (P < 0.05). The subjective satisfaction degree was good in 16 cases, moderate in 10 cases, and poor in 5 cases. Periprosthetic infection occurred in 2 cases (3 knees), joint stiffness in 3 cases (6 knees), joint instability in 1 case (1 knee), leg length discrepancy of > 2 cm in 2 cases, and flexion deformity of 10° in 1 case (1 knee). The hip and knee ROM values, Harris score and HSS score showed no significant difference between patients with ankylosing spondylitis and patients rheumatoid arthritis at last follow-up (P > 0.05). The hip and knee ROM values of the patients with ankylosed joint were significantly lower than those of patients with no ankylosed joint (P < 0.05); the Harris score and HSS score of the patients with ankylosed joint were lower than those of patients with no ankylosed joint, but no significant difference was found (P > 0.05). ConclusionA combination of bilateral hip and knee arthroplasty is an efficient treatment for severe lower extremities deformity, arthralgia and poor quality of life caused by inflammatory arthropathies. However, the postoperative periprosthetic infection and stiffness of knee are important complications influencing the effectiveness of operation.
ObjectiveTo investigate the accuracy of preoperative digital-template planning in total hip arthroplasty (THA) via direct anterior approach (DAA) and its effect on the short-term effectiveness.MethodsThe clinical data of 77 patients (109 hips) with osteonecrosis of femoral head who underwent THA via DAA between January 2016 and May 2018 was retrospectively analyzed. According to the type of template, patients were divided into digital-template group (group A, 40 patients, 56 hips) and conventional-template group (group B, 37 patients, 53 hips). There was no significant difference in age, gender, body mass index, the stages of osteonecrosis of femoral head, and preoperative Harris hip score (HHS) (P>0.05). The operation time, intraoperative blood loss, frequencies of intraoperative fluoroscopy, and complications were recorded. Otherwise, the consistency rate of preoperative planning and practical prosthesis size was analyzed. Position of acetabular prosthesis and femoral prosthesis alignment were measured on anteroposterior X-ray film of the pelvis at 3 months after operation. HHS was used to evaluate clinical function.ResultsThe consistency rate of preoperative planning and practical acetabular prosthesis size was significantly higher in group A (80.4%, 45/56) than that in group B (62.3%, 33/53), showing significant difference (χ2=4.38, P=0.04). But there was no significant difference in the consistency rate of preoperative planning and practical femoral prosthesis size between group A (83.9%, 47/56) and group B (79.2%, 42/53)(χ2=0.40, P=0.53). The prosthesis abductions were (40.7±6.4)° in group A and (38.8±7.3)° in group B; the femoral prosthesis alignment deviations were (0.1±1.8)° in group A and (0.3±1.7)° in group B. There was no significant difference in the prosthesis abduction and femoral prosthesis alignment deviation between 2 groups (P>0.05). No prosthesis sinking or loosening occurred during follow-up. The operation time and frequencies of intraoperative fluoroscopy were less in group A than those in group B (P<0.05). But there was no significant difference in intraoperative blood loss between 2 groups (t=1.92, P=0.06). The complication occurred in 1 hip of group A and 6 hips of group B, with no significant difference (P=0.06). All patients were followed up 6-22 months (mean 13.8 months) in group A and 6-24 months (mean, 14.6 months) in group B. At last follow-up, the HHS scores were 91.8±3.1 in group A and 92.6±4.2 in group B, and the difference was not significant (t=1.14, P=0.26).ConclusionPreoperative digital-template planning in THA via DAA is accurate, which can reduce the operation time and frequencies of intraoperative fluoroscopy without enhancing the risk of complication.