Objective To assess the efficacy and safety of percutaneous closure of patent ductus arteriosus (PDA) solely under echocardiography guidance. Methods We retrospectively analyzed the clinical data of 200 patients who received the percutaneous closure of PDA under echocardiography guidance in Fuwai Hospital from August 2013 to April 2016. According the different approach, they were divided into 2 groups: a femoral artery approach group (n=143) and a femoral vein approach group (n=57). In the femoral artery approach group, there were 42 males and 101 females aged 3.20±5.63 years. In the femoral vein group, there were 10 males and 47 females aged 7.30±11.36 years. All Patients were treated by percutaneous PDA closure solely under echocardiography guidance. The follow-up was performed at one month after the operation by echocardiography, chest radiograph and electrocardiogram. Results All 200 patients were successfully treated with percutaneous closure of PDA. The patients’ gender, in-hospital stay, rates of occluder detachment were similar between the two groups (P>0.05). Compared with the femoral vein approach group, the femoral artery approach group had a younger age (3.20±5.63 yearsvs. 7.30±11.36 years, P<0.001), less body weight (14.25±11.54 kgvs. 24.25±19.14 kg, P<0.001) and shorter diameter of PDA (3.06±0.79 mmvs. 5.93±0.68 mm, P<0.001) and PDA occluders (5.43±1.00 mmvs. 12.14±0.54 mm, P<0.001), but had higher hospitalization expenses (32 108.2±3 100.2 yuanvs.25 120.7±3 534.1 yuan, P<0.001). In the femoral vein approach group, one patient was closed under radiation guidance because guide wires could not pass through PDA. One patient in the femoral artery approach group suffered from occluder detachment at one day after operation and was cured by transthoracic minimally invasive PDA occlusion. There were no complications of occluder detachment, residual shunt, pericardial effusion or left pulmonary stenosis during the follow-up. Conclusion Echocardiography-guided percutaneous PDA closure is safe and effective, while the proper interventional approach should be chosen by the anatomical features of PDA.
Transcatheter aortic valve replacement is an effective treatment for aortic stenosis currently, especially in elderly, surgical high-risk, and surgical procedures-intolerant patients with severe aortic stenosis. After several generations of updates in design and function, the self-expandable valves have shown significant efficacy in treating aortic stenosis patients with bicuspid aortic valve, bioprosthetic valve failure or small annulus, and superiority in terms of valve durability, and the favorable hemodynamic outcomes could translate into clinical endpoint benefit. This literature review summarizes the advantages and recent advances of the self-expandable valves in transcatheter aortic valve replacement.
In recent years, heart valve disease has been increasing year by year. Transcatheter aortic valve replacement (TAVR) has become the first-line surgical method for patients with severe aortic stenosis due to the advantages of small surgical trauma and rapid postoperative recovery. In the context of the rapid development of TAVR, the postoperative complications of TAVR seriously affect the surgical success rate and patient prognosis. Therefore, the prevention and nursing of complications after TAVR are particularly important. This article will review the assessment, prevention and care of the complications such as arrhythmia, vascular complications, perivalvular leakage, stroke, and acute renal failure after TAVR in combination with the current situation at home and abroad, in order to enhance the clinical medical workers’ understanding of the complications.
Mitral regurgitation (MR) with multi-pathogenesis is a common disease in cardiac surgery department. MR can be classified into two categories-primary mitral regurgitation and secondary mitral regurgitation. With the development of cardiac intervention, numerous patients who cannot tolerate open heart surgery for the reason of high risk of surgery receive the treatment of intervention and achieve the favorable endpoint. The technique of transcatheter therapy which could be used to treat MR is comprised of leaflet repair, annuloplasty and implantation of artificial chordae. Comparing to primary mitral regurgitation, surgical effect of secondary mitral regurgitation is not desirable for the reasons of complex pathophysiologic mechanism. Hence, based on the perspective of surgeon, we will introduce the research progress of transcatheter interventional mitral valve repair which is focused on the treatment of primary mitral valve regurgitation and reviewed from three aspects of surgical risks, surgical types and outlook.
Objective To evaluate the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 system. MethodsThis was a prospective, multicenter, single arm study in 4 centers in China. The clinical data of 50 patients with high-risk symptomatic severe aortic stenosis who underwent TAVR using the SAPIEN 3 system from June 2017 to June 2019 were analyzed, including 27 males and 23 females aged 76.8±6.1 years. ResultsThe Society of Thoracic Surgeon score was 6.0%±2.8%. Totally, 20.0% of patients had severe bicuspid aortic stenosis. The operation time was 41.8±16.5 min and the hospital stay time was 8.5±5.0 d. At the postoperative 30-day follow-up, no all-cause mortality occurred and the device success rate was 89.5%. Major vascular complications occurred in one (2.0%) patient, stroke in one (2.0%) patient, new pacemaker implantation in one (2.0%) patient, as well as coronary artery obstruction in one (2.0%) patient. There was no moderate or moderate/severe paravalvular leak. The aortic pressure gradient was decreased from 49.2±16.2 mm Hg before the operation to 12.4±4.6 mm Hg at the postoperative 30-day follow-up, and the valvular area was increased from 0.6±0.3 cm2 to 1.3±0.3 cm2 (P<0.01). Moreover, the New York Heart Association classification in 83.7% of the patients was improved during the follow-up. ConclusionThis pre-marketing multicenter study has demonstrated the safety and effectiveness of transfemoral TAVR with the SAPIEN 3 transcatheter valve system in Chinese aortic stenosis patients at high risk for surgery.
ObjectiveTo investigate the operation of transcatheter aortic valve replacement (TAVR), the use of TAVR instruments and the current situation of TAVR-related nursing in our country, to reveal the characteristics of TAVR in various hospitals in our country, and to provide reference data for improving perioperative nursing and industry development of TAVR. MethodsA questionnaire survey was conducted among the head nurses of the cardiac catheterization laboratories of 51 hospitals in China that carried out TAVR operations, with a total of 5 items and 23 questions. The current situation of TAVR operation methods, intraoperative instruments and nursing care in China were analyzed. ResultsThe number of hospitals in China which started conducting TAVR and the beginning year were: 2 in 2010, 1 in 2012, 1 in 2013, 1 in 2015, 11 in 2016, 13 in 2017, 15 in 2018 and 7 in 2019; the number of transfemoral TAVR in 2019: 32 (62.75%) hospitals conducted on less than 20 patients, 7 (13.73%) hospitals 20-<50 patients, 6 (11.76%) hospitals 50-100 patients and 6 (11.76%) hospitals more than 100 patients; TAVR strategies adopted by most hospitals were: general anesthesia (90.20%), the use of vascular sealers (80.39%), backing by cardiac surgeon (74.51%) and using homemade prosthetic valves. Conclusion At present, the number of TAVR carried out in Chinese hospitals is still far behind that of developed countries in Europe and the United States. Our country has adopted the form of multidisciplinary cardiac team cooperation and formed a TAVR nursing model with Chinese characteristics.
An 89 years old male patient was admitted to the First Medical Center of Chinese PLA General Hospital due to chest tightness and shortness of breath for half a month. Severe aortic valve stenosis was found in post admission assessment. We proposed to perform transcatheter aortic valve replacement surgery. Preoperative evaluation showed severe distortion of the descending aorta. We used the double guide wire technique and a 14F long sheath to assist the stepwise balloon expansion, and successfully completed the valve implantation. For patients with severe tortuous aorta, how to successfully complete transcatheter aortic valve replacement, this case may provide some reference.
This paper discusses a female patient with severe aortic stenosis, who was preoperatively assessed to be at high risk of left coronary artery occlusion, but developed complete occlusion of the right coronary artery during the procedure of transcatheter aortic valve replacement, leading to hemodynamic disorder. Surgical treatment under emergency cardiopulmonary bypass played a critical role in rescuing the patient.