west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "尺骨鹰嘴骨折" 4 results
  • Mayo Ⅱ B 型尺骨鹰嘴骨折的关节面重建

    目的 总结Mayo ⅡB型尺骨鹰嘴骨折术中重建滑车切迹关节面的方法及疗效。 方法 2009年1 月-2010 年12 月,收治10 例直接暴力所致Mayo Ⅱ B 型尺骨鹰嘴骨折患者。男6 例,女4 例;年龄21 ~ 65 岁,平均31.5 岁。受伤至手术时间为2 ~ 11 d,平均5 d。术中根据滑车切迹关节面骨缺损程度,采用直接复位、截骨短缩复位或植骨重建关节面。 结果 术后切口均Ⅰ期愈合。患者均获随访,随访时间8 ~ 13 个月,平均10 个月。X线片示骨折愈合时间为6 ~8 周,平均6.5 周;无关节面塌陷等并发症发生。术后8 个月根据Mayo 关节功能评分标准评定疗效,获优6 例,良3 例,可1 例,优良率为90%。 结论 对于Mayo Ⅱ B 型尺骨鹰嘴骨折,术中重建滑车切迹关节面是恢复肘关节良好功能的基础。

    Release date:2016-08-31 04:23 Export PDF Favorites Scan
  • 改良张力带技术治疗尺骨鹰嘴骨折

    目的总结改良张力带技术治疗尺骨鹰嘴骨折的疗效。 方法2009年1月-2012年3月采用改良张力带技术治疗41例尺骨鹰嘴骨折患者。男29例,女12例;年龄18~65岁,平均39岁。致伤原因:摔伤25例,交通事故伤12例,打击伤4例。横形及斜形骨折26例,粉碎性骨折15例;开放性骨折9例。按Mayo临床分型标准:Ⅰ型4例,Ⅱ型31例,Ⅲ型6例。受伤至手术时间3 h~7 d,平均2.5 d。 结果术后患者切口均Ⅰ期愈合,无感染及尺神经损伤等早期并发症发生。41例均获随访,随访时间15~21个月,平均17个月。克氏针及钢丝断端未对周围组织造成激惹,均无钢丝折断发生;术后无骨折移位、再骨折及异位骨化等并发症发生。X线片示骨折均愈合,愈合时间6~8周,平均6.9周。术后12个月根据Broberg-Morrey标准评定肘关节功能:优29例,良12例,优良率100%。 结论改良张力带技术加压力量强大、可控,治疗尺骨鹰嘴骨折疗效较好。

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS OF SHARP TEETH HOOK PLATE FOR TREATMENT OF OLECRANON FRACTURES

    ObjectiveTo investigate the effectiveness of sharp teeth hook plate by cutting for the treatment of olecranon fractures by comparison with Kirschner wire tension belt and locking plate. MethodsBetween January 2011 and April 2015, 32 cases of olecranon fractures were treated. Fracture was fixed with sharp teeth hook plate by cutting in 12 cases (trial group) and with Kirschner wire tension belt or locking plate in 20 cases (control group). There was no significant difference in gender, age, side and type of fracture, and time from injury to operation between 2 groups (P > 0.05). The healing time of fractures and complications were recorded. At 1 year after operation, the subjective function results were evaluated according to Disability of Arm, Shoulder, and Hand (DASH) score, and objective function results by Mayo Elbow Score (MEPS); visual analogue scale (VAS) was used for elbow joint pain, and range of motion of flexion and extension of elbow joint was measured. ResultsAll incisions healed by first intention, with no vascular and nerve injuries. All patients were followed up 12-36 months with an average of 18 months. All fractures healed, and there was no significant difference in the healing time between 2 groups (P > 0.05). Loosening of Kirschner wire occurred in 2 cases of control group, but no loosening of internal fixation was observed in trial group after operation. There was no significant difference in the incidence of complications between 2 groups (P > 0.05). The DASH, MEPS, VAS score, and range of motion of flexion in trial group were superior to those in control group, showing significant differences (P < 0.05) at 1 year after operation. There was no significant difference in range of motion of extension between 2 groups (P > 0.05). ConclusionSharp teeth hook plate for treatment of olecranon fractures overcomes the shortcomings that Kirschner wire tension is easy to slide and locking plate has a compression effect on triceps tendon, so it has good effectiveness.

    Release date:2016-10-02 04:55 Export PDF Favorites Scan
  • EFFECTIVENESS OF POSTEROMEDIAL DOUBLE PLATES IN TREATMENT OF COMPLEX OLECRANAL FRACTURE

    ObjectiveTo evaluate the effectiveness of posteromedial double plates in the treatment of complex olecranal fracture. MethodsBetween September 2011 and July 2015, 13 patients with complex olecranal fractures were treated with posterior olecranon locking compression plate and medial mini-plate. There were 8 males and 5 females with an average age of 41.6 years (range, 22-68 years). Injury was caused by traffic accident in 4 cases, falling from height in 6 cases, and crush by object in 3 cases. According to the Mayo classification, fracture was rated as Mayo type ⅡB in 5 cases and as Mayo type ⅢB in 8 cases. Of 13 cases, 7 had Regan-Morrey type Ⅲ coronoid fractures, including 5 anterior dislocations of the elbow joint and 2 posterior dislocations. The time between injury and admission ranged from 1.5 to 10.0 hours (mean, 5.7 hours). At last follow-up, the elbow function was assessed according to the Broberg-Morrey evaluation criteria. X-ray films was performed to observe fracture healing. ResultsAll incisions healed at first stage and no neural complications occurred. The patients were followed up 9-38 months (mean, 22.1 months). All patients achieved bone union at 3.0-5.5 months (mean, 3.7 months) according to X-ray results. Subluxation of radial head and mild heterotopic ossification occurred in 1 patient respectively, who had no uncomfortable symptoms of movement disorder, elbow instability and pain, and no special management was performed. At last follow-up, the flexion and extension range of motion (ROM) of the elbow was 95-130° (mean, 116.4°); the rotation ROM of the forearm was 150-175° (mean, 170.8°); and the elbow function was excellent in 4 cases, good in 7 cases, and fair in 2 cases, and the excellent and good rate was 84.6%. No internal fixation failure, elbow stiffness, or traumatic arthritis occurred. ConclusionFor complex olecranal fractures, an early and stable anatomic reconstruction of trochlear notch in the olecranon with posterior olecranon locking compression plate and medial mini-plate can obtain good effectiveness in joint functions.

    Release date:2016-12-12 09:20 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content