west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "张亮" 17 results
  • MID-TERM RESULTS OF TOTAL HIP ARTHROPLASTY FOR TREATMENT OF ANKYLOSING SPONDYLITIS

    ObjectiveTo investigate the clinical and radiographic results of total hip arthroplasty (THA) for the treatment of hip arthrosis in patients with ankylosing spondylitis (AS). MethodsA retrospective analysis was made on the clinical data from 131 patients (195 hips) who underwent THA for AS between September 2001 and August 2011 with a follow-up period of more than 2 years. There were 100 males (152 hips) and 31 females (43 hips), aged 17-69 years (mean, 33.7 years). The average interval between AS onset and THA was 13.7 years (range, 1-50 years). The left hips were involved in 30 cases, the right hips in 37 cases, and bilateral hips in 64 cases. Preoperative Harris hip score was 18.0±13.7; the sum passive range of motion was (36.2±51.2)°; and the hip passive-flexion arc was (23.4±32.6)°. In 175 hips with passive flexion of less than 90°, 134 hips had flexion contracture. Based on preoperative X-ray films and CT scan, 195 hips were divided into the non-ankylosed subgroup (86 hips), fibrous ankylosed subgroup (43 hips), and bony ankylosed subgroup (66 hips); and the recovery of hip function was compared between subgroups after operation. ResultsIntraoperative complications included linear fractures of femoral calcar in 4 hips, fractures of acetabular posterior column in 1 hip, femoral shaft fractures in 2 hips, and iatrogenic sciatic nerve injury in 3 hips; postoperative complications included anterior dislocation in 2 hips. The average follow-up period was 51.3 months (range, 24-143 months). Bone healing was observed at 3-6 months after operation (mean, 3.9 months). At last follow-up, the average Harris hip score increased to 86.4±14.1, the sum passive range of motion increased to (202.0±28.0)°, and the hip passive-flexion arc increased to (93.2±15.3)°, all showing significant differences when compared with preoperative ones (P<0.05). Based on a four-class scale for subjective satisfaction, the patients were very satisfied, satisfied, and not satisfied with the results of THA in 100, 80, and 15 hips respectively. X-ray films showed radiolucent line (<2 mm) in 5 acetabular components (zones I and II); heterotopic ossification was observed in 49 hips after THA. There was no significant difference in the Harris hip score among 3 subgroups after THA at last follow-up (P>0.05). At last follow-up, the degree of passive flexion in the fibrous ankylosed subgroup and bony ankylosed subgroup was significantly lower than that in the non-ankylosed subgroup (P<0.05), and the sum passive range of motion in the fibrous ankylosed subgroup was significantly lower than that in the non-ankylosed subgroup (P<0.05), but no significant difference was found in the other variables among the 3 sub groups (P>0.05). ConclusionFor severe hip arthrosis in patients with AS, the overall outcomes after THA are ideal with a good midterm prosthetic survivorship, a low complication rate, and a high satisfaction of patients. However the hip function after THA is still less satisfactory.

    Release date: Export PDF Favorites Scan
  • Research progress of endogenous repair strategy in intervertebral disc

    ObjectiveTo review the research progress of endogenous repair strategy (ERS) in intervertebral disc (IVD).MethodsThe domestic and foreign literature related to ERS in IVD in recent years was reviewed, and its characteristics, status, and prospect in the future were summarized.ResultsThe key of ERS in IVD is to improve the vitality of stem/progenitor cells in IVD or promote its migration from stem cell Niche to the tissue that need to repair. These stem/progenitor cells in IVD are derived from nucleus pulposus, annulus fibrosus, and cartilaginous endplate, showing similar biological characteristics to mesenchymal stem cells including the expression of the specific stem/progenitor cell surface markers and gene, and also the capacity of multiple differentiations potential. However, the development, senescence, and degeneration of IVD have consumed these stem/progenitor cells, and the harsh internal microenvironment further impair their biological characteristics, which leads to the failure of endogenous repair in IVD. At present, relevant research mainly focuses on improving the biological characteristics of endogenous stem/progenitor cells, directly supplementing endogenous stem/progenitor cells, biomaterials and small molecule compounds to stimulate the endogenous repair in IVD, so as to improve the effect of endogenous repair.ConclusionAt present, ERS has gotten some achievements in the treatment of IVD degeneration, but its related studies are still in the pre-clinical stage. So further studies regarding ERS should be carried out in the future, especially in vivo experiments and clinical transformation.

    Release date:2021-06-07 02:00 Export PDF Favorites Scan
  • Experiment Research of Mitral Valve Coaptation Area and Coaptation Index China

    Objective To investigate the changing tendency of mitral valve coaptation area and coaptation index of moderate mitral regurgitation (MR) in a dog experiment,and provide evidence for predicting long-term surgical results. Methods Real-time three-dimensional transesophogeal echocardiography (RT-3D-TEE) images were obtained in 15 dogs via Philips IE33 echocardiography system,and animal experiment model was established. RT-3D-TEE images were taken by gradually narrowing the ascending aorta and increasing left ventricular pressure till moderate MR. Original data were analyzed using Philips Qlab 7.0 three-dimensional quantification software,and mitral valve coaptation area and coaptation index were calculated. Specimen coaptation index of the mitral leaflets was calculated after the animal experiment. Cutoff values of coaptation index and left ventricular pressure were calculated by receiver operating characteristic (ROC) curve. Results There was statistical difference in coaptation area (198±50)mm2 vs. (123±36)mm2,P<0.05) and coaptationindex (0.25±0.06 vs. 0.13±0.03,P<0.05) between non-MR state and MR status of the 15 dogs. The area under the ROC curve of coaptation index and moderate MR was 0.879±0.019 with 95% CI 0.843 to 0.916,and the cutoff value was 0.213(P<0.05). The area under the ROC curve of left ventricular pressure and moderate MR was 0.882±0.021 swith 95% CI 0.840 to 0.923,and the cutoff value was 225 (P<0.05). There was no statistical difference between specimen mitral valve area and early-diastolic mitral leaflet area,specimen coaptation area and coaptation area,specimen coaptation index and coaptation index (P>0.05). Early-diastolic mitral leaflet area was significantly correlated with specimen mitral valve area (r=0.937,P<0.05). Coaptation area was significantly correlated with specimen coaptation area (r=0.917,P<0.05). Coaptation index was significantly correlated with specimen coaptation index (r=0.946,P<0.05). The correlation of coaptation index and specimen coaptation index was higher than those of coaptation area and specimen coaptation area,and earlydiastolic mitral leaflet area and specimen mitral valve area. Conclusions Both coaptation area and coaptation index significantly decrease in MR status. Coaptation index can more precisely reflect MR degree,and provide reference for prognosis of mitral valve repair. RT-3D TEE can accurately measure mitral valve coaptation area and coaptation index.

    Release date:2016-08-30 05:47 Export PDF Favorites Scan
  • A Detection Method of Liver Iron Overload Based on Static Field Magnetization Principle

    Magnetic induction method aims at the noninvasive detection of liver iron overload by measuring the hepatic magnetic susceptibility. To solve the difficulty that eddy current effects interfere with the measurement of magnetic susceptibility, we proposed an improved coil system based on the static field magnetization principle in this study. We used a direct current excitation to eliminate the eddy current effect, and a rotary receiver coil to get the induced voltage. The magnetic field for a cylindrical object due to the magnetization effect was calculated and the relative change of maximum induced voltage was derived. The correlation between magnetic susceptibility of object and maximum magnetic flux, maximum induced voltage and relative change of maximum induced voltage of the receiver coil were obtained by simulation experiments, and the results were compared with those of the theory calculation. The contrast shows that the simulation results fit the theory results well, which proves our method can eliminate the eddy current effect effectively.

    Release date: Export PDF Favorites Scan
  • MID-TERM RESULTS OF TOTAL HIP ARTHROPLASTY FOR OSTEOARTHRITIS SECONDARY TO HIP SEPSIS

    ObjectiveTo evaluate mid-term results of total hip arthroplasty (THA) for treatment of osteoarthritis secondary to hip sepsis. MethodsBetween February 2003 and January 2009, 62 patients (62 hips) with osteoarthritis secondary to hip sepsis underwent THA. There were 32 males and 30 females with an average age of 39.9 years (range, 18-67 years). The original infection included pyogenic arthritis in 40 hips and tuberculosis in 22 hips. After infection, 35 patients underwent non-operative treatment, and 27 patients received operative management. The average time interval between initial infection and THA was 28.7 years (range, 12-53 years). The preoperative Harris hip score was 24.6±9.2. The Trendelenburg sign was positive in all hips. Leg discrepancy was observed in 25 cases, and the mean discrepancy of bilateral lower extremities was 3.8 cm (range, 2.6-6.5 cm) preoperatively. All hips had no evidence of active hip sepsis. ResultsAll patients were followed up 72 months on average (range, 54-115 months). Intraoperative complications included sciatic nerve injury (2 cases) and femoral shaft fractures (2 cases); postoperative complications included hip anterior dislocation (1 case) and periprosthetic infection (1 case). At last follow-up, 1 hip, 5 hips, 18 hips, and 38 hips were found to have severe pain, moderate pain, slight pain, and no pain respectively. Claudication occurred in 30 patients (mild in 19, moderate in 8, and severe in 3). The Trendelenburg sign was positive in 18 hips. After THA, only 5 patients had a leg length discrepancy of 2.9 cm on average (range, 2.6-3.5 cm). The Harris score was significantly increased to 82.3±11.4 at last follow-up when compared with preoperative one (t=-31.241, P=0.000). The results of subjective satisfaction were very satisfactory in 43 cases, satisfactory in 12 cases, unsatisfactory in 4 cases, and unsatisfactory at all in 3 cases. No sign of aseptic loosening of prosthesis was found during follow-up period. Roentgenographic results showed no radiolucent line or osteolysis in the other patients except 2 patients having local radiolucent. After THA, 12 hips had heterotopic ossification. ConclusionThe mid-term clinical and radiographic results of THA for treatment of osteoarthritis secondary to hip sepsis are good, with the advantages of high satisfactory rate, good function recovery, and low complication incidence.

    Release date: Export PDF Favorites Scan
  • The simulative study of a new probe for the in vivo dielectric measurement of anisotropic tissue in radio frequency band

    In this paper, a new probe is proposed for the in vivo dielectric measurement of anisotropic tissue in radio frequency band, which could accomplish the dielectric measurement in perpendicular directions by one operation. The simulative studies are performed in the frequency range from 1–1 000 MHz in order to investigate the influence of probe dimension on the energy coupling and sensitivity of measurement. The suitable probe is designed and validated for the actual measurement in this frequency band. According to the simulation results, the energy coupling of the probe could be kept below –12 dB in the frequency range from 200–400 MHz with high sensitivity of measurement for the dielectric properties of anisotropic tissue. That indicates the new type of probe has the potential to achieve the dielectric measurement of anisotropic tissue in radio frequency band and could avoid the measurement error by multi-operations in the conventional method. This new type of probe could provide a new method for the in vivo dielectric measurement of anisotropic tissue in radio frequency band.

    Release date:2018-02-26 09:34 Export PDF Favorites Scan
  • Study on the difference of high frequency dielectric properties of biological tissues measured by air and packed coaxial probe

    In this paper, the differences between air probe and filled probe for measuring high-frequency dielectric properties of biological tissues are investigated based on the equivalent circuit model to provide a reference for the methodology of high-frequency measurement of biological tissue dielectric properties. Two types of probes were used to measure different concentrations of NaCl solution in the frequency band of 100 MHz–2 GHz. The results showed that the accuracy and reliability of the calculated results of the air probe were lower than that of the filled probe, especially the dielectric coefficient of the measured material, and the higher the concentration of NaCl solution, the higher the error. By laminating the probe terminal, liquid intrusion could be prevented, to a certain extent, to improve the accuracy of measurement. However, as the frequency decreased, the influence of the film on the measurement increased and the measurement accuracy decreased. The results of the study show that the air probe, despite its simple dimensional design and easy calibration, differs from the conventional equivalent circuit model in actual measurements, and the model needs to be re-corrected for actual use. The filled probe matches the equivalent circuit model better, and therefore has better measurement accuracy and reliability.

    Release date: Export PDF Favorites Scan
  • Study on The Effect of Endovascular Treatment Guided by Ultrasonography Combined with Portosystemic Shunts for Budd-Chiari Syndrome

    Objective To explore the effect of endovascular treatment guided by ultrasonography combined with portosystemic shunts on the patients with Budd-Chiari Syndrome (BCS).Methods The clinical data of 136 patients with BCS treated by balloon angioplasty and stent implantation guided by Doppler ultrasonography in our hospital from January 1995 to January 2011 were retrospectively analyzed.After balloon angioplasty,53 patients were treated by inferior vena cava (IVC) stent implantation and 31 patients with hepatic venous occlusion underwent portosystemic shunts (PSSs) at one week after endovascular treatment.The long-and short-term effects after treatment were studied.Results After endovascular procedures,the IVC pressure of patients significantly decreased (P<0.01),while IVC diameter, flow velocity in the lesion,and right atrial pressure of patients showed significant increase(P<0.01).Slight heart dysfunction appeared in 13 cases of patients.After shunting,acute pancreatitis occurred in 3 cases, and 1 patient died of upper gastrointestinal hemorrhage on the 10 d after PSSs.Doppler ultrasonography for IVC and shunt vessels showed:the swollen liver and spleen lessened on 3d after endovascular procedures.The swollen liver lessened 2-7cm (mean 5.5cm),swollen spleen lessened 3-8cm (mean 5.8cm), and the time of ascites disappearance was 3-60d (mean 14d).All the patients were followed up for 1 month to 15 years with an average of 3 years.Restenosis of the distal part of stent was found in 1 patient in 2 years after operation, hepatic vein occlusion occurred in 1 case in 1 year after treatment,hepatocellular carcinoma occurred in 1 patient in 3 years after stent implantation,and 1 patient died of C type hepatitis after 1 year,and 5 out of 6 cases of patients with infertility had babies after 1 year.All patients had no stent migration or occlusion of shunts and the symptoms of portal hypertension were obviously relieved.Conclusions Endovascular treatment guided by Doppler ultrasonography is a convenient,safe,and effective method for BCS.Portosystemic shunts are commended to patients with hepatic venous occlusions.The above mentioned methods provide a feasible and effective means for IVC stenosis and short segment occlusion with hepatic vein occlusion of BCS.

    Release date: Export PDF Favorites Scan
  • Clinical Study of Vena Cava Filter in Preventing from Pulmonary Embolism Induced by Lower Extremity Deep Venous Thrombosis

    Objective To summarize the probability of pulmonary embolism (PE) induced by lower extremity deep venous thrombosis (DVT) and investigate the role of vena cava filter (VCF) in preventing from PE. Methods The clinical data of 1 058 patients with lower extremity DVT from January 2005 to January 2012 were analyzed retrospectively. Results The PE rate was 3.21% (34/1 058) and the death rate was 1.42% (15/1 058) in 1 058 patients with lower extremity DVT. The VCF was implanted in 171 of 1 058 patients. The VCFs of 151 patients were implanted from femoral vein, 20 patients were implanted from jugular vein. The PE rates were 3.61% (32/887) and 1.17% (2/171) and the death rates were 1.69% (15/887) and 0 (0/171) in patients without VCF and with VCF, respectively. Both of them occurred in the first ten days. PE could keep as long as 35 d. The PE rate and death rate in the patients without VCF were significantly higher than those in the patients with VCF (P<0.01). The PE rates and death rates in both lower extremities DVT were higher than those in patients with the right and left ones (P<0.05), which in the right lower extremity were higher than those in the left one (P<0.05). The PE rate and death rate in the patients with lower extremity DVT combined with vena cava thrombosis were significantly higher than those in the patients with central type (P<0.05), which in the central type were significantly higher than those in the peripheral type (P<0.05), there were no significant differences between peripheral type and mixed pattern. The follow-up time was from 1 month to 7 years with (39±19) months, the patency rate of VCF was 98.7%. There were no filter migration, declination, and failure of expansion. Conclusions VCF can prevent from PE effectively, but the indications must be controlled.

    Release date:2016-09-08 10:36 Export PDF Favorites Scan
  • 手术内固定治疗创伤性连枷胸对患者呼吸功能的影响

    目的观察连枷胸患者胸壁加压包扎、肋骨牵引和手术内固定的治疗效果。 方法纳入2001年1月至2010年6月解放军第一医院心胸外科收治的56例连枷胸患者,分为3组:牵引治疗组,14例,其中男10例、女4例,年龄(39.7±11.6)岁;包扎治疗组,12例,其中男11例、女1例,年龄(40.2±13.2)岁;手术内固定组,30例,其中男26例、女4例,年龄(42.6±12.5)岁。比较3组的治疗效果。 结果手术内固定组与牵引治疗组和包扎治疗组比较,除需呼吸机支持率与牵引治疗组差异无统计学意义(P>0.05)外,呼吸机通气时间、住ICU时间、胸腔引流管拔除时间均缩短(P<0.05),胸部并发症发生率及死亡率降低(P<0.05),动脉血氧分压(PaO2)、动脉血氧饱和度(SaO2)显著升高(P<0.01),肺挫伤评分下降明显;而牵引治疗组PaO2、SaO2及肺挫伤评分较入院时改善缓慢,胸壁加压包扎治疗组甚至有加重趋势。 结论大面积浮动胸壁的病理改变以胸腔容积减少为基础,胸壁加压包扎无治疗效果,甚至加重低氧;肋骨巾钳悬吊牵引固定对连枷胸缺氧内环境的改善效果不佳;手术切开复位内固定是改善大面积浮动胸壁呼吸功能障碍的有效方法。

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content