west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "张航" 11 results
  • A Comparison Study on Early Damage Detection of Left Ventricular Function Based on Doppler Imaging Method for Children with Tumor

    The early damage detection and evaluation are of great significance in treatment and prognosis to the left ventricular function for children with tumor. In this paper, it is reported that the early damage of the left ventricular function was observed by pulsed wave Doppler (PWD) and tissue Doppler imaging (TDI) in our laboratory. Eighty children half a year to fourteen years old were included in this study. The cardiac function indices in chemotherapy group and control group were measured and compared. The results showed that there was significant difference in mitral and tricuspid annulus flow spectrum between the two groups. Compared with PWD, TDI is more prompt, objective and accurate in detecting early damage of left ventricular function in children with tumor.And TDI is a good method for early identification of ventricular function damage in children with tumor.

    Release date: Export PDF Favorites Scan
  • Influence of Mechanical versus Hand-sewn Anastomosis on Surgical Complications of Patients with Esophageal Carcinoma after Esophagectomy: A Systematic Review and Meta-analysis

    ObjectiveTo compare the complication morbidity of mechanical and hand-sewn esophagogastric anastomosis systemically. MethodsMedline (January 1960 to June 2015), EMbase (January 1980 to June 2015), Cochrane Library (January 1996 to June 2015), Web of Science (January 1980 to June 2015) and other databases were searched to identify randomized controlled trials (RCTs) about comparing the complication morbidity of hand-sewn and mechanical anastomosis. Moreover, the references were searched by search engines such as Google Scholar. Papers were screened according to the inclusion and exclusion criteria. And then the data were extracted. The quality of current meta-analysis was assessed by GRADE profiler 3.6 software. The meta-analysis was conducted using Stata 12.0 software. ResultsA total of 1 611 patients in 14 RCTs were reviewed. The results suggested that the anastomatic leakage rate of mechanical method showed no significant difference from that of hand-sewn method[RR=1.07, 95%CI (0.76, 1.51), P=0.699]. While the anastomatic stenosis rate was even higher[RR=1.59, 95%CI (1.21, 2.09), P=0.001]. ConclusionMechanical method can't reduce the anastomotic leakage rate following esophagogastrostomy, while it maybe increase the risk of anastomotic stenosis on the contrary. The patients' physical condition should be considered when surgeons make the choice.

    Release date: Export PDF Favorites Scan
  • 急诊经导管主动脉瓣置换联合动脉导管未闭封堵、经皮冠状动脉介入“一站式”手术抢救重症心力衰竭患者一例

    Release date: Export PDF Favorites Scan
  • Risk factors and perioperative outcomes of prolonged mechanical ventilation after coronary artery bypass grafting in elderly patients

    Objective To investigate the clinical characteristics, risk factors and perioperative outcome of prolonged mechanical ventilation (PMV) in elderly patients undergoing coronary artery bypass grafting (CABG). Methods The data of elderly patients receiving CABG in the Nanjing First Hospital from January 2013 to June 2019 were collected. All patients were divided into a control group and a PMV group according to whether ventilation time≥24 h.The clinical characteristics and risk factors of PMV were compared between the two groups. Variables were 1∶1 balanced through propensity score matching (PSM) and perioperative outcomes of two groups was analyzed. Results Finally 956 patients were collected, including 187 in the PMV group and 769 in the control group. There were 586 males and 370 females aged 70-94 (74.3±3.5) years. Compared with the control group, the PMV group had higher rates of smoking, preoperative renal impairment, intraoperative blood transfusion and intra-aortic balloon pump (IABP) implantation, worse cardiac function, lower glomerular filtration rate and ejection fraction, larger left atrial diameter, longer cardiopulmonary bypass time and aortic cross-clamping time (P<0.05). There was no statistical difference in other clinical data between the two groups (P>0.05). Binary multivariate logistic regression analysis showed that females, smoking, chronic obstructive pulmonary disease, left ventricular ejection fraction≤56.0%, cardiopulmonary bypass time>106.0 min, IABP implantation and intraoperative blood transfusion were independent risk factors for PMV in elderly patients. After PSM, there were 146 patients in the control group and the PMV group, respectively. The PMV group had longer ICU stay and length of hospital stay and more drainage volume compared with the control group (all P<0.05). There was no statistical difference in perioperative mortality or other complications between the two groups (all P>0.05). ConclusionThere are a lot of factors associated with PMV of the elderly patients undergoing on-pump CABG. In order to establish a complete and formal PMV prediction model, clinicians can make a further step of assessment according to perioperative elements, and improve the prognosis of such patients.

    Release date: Export PDF Favorites Scan
  • Relationship between Bicuspid Aortic Valve and Ascending Aortic Dilatation Assessed by Computed Tomography Angiography

    ObjectiveTo find the relationship between bicuspid aortic valve (BAV) and the dilatation or aneurysm of the aorta using electrocardiogram-gated computed tomography angiography (CTA). MethodsWe collected the clinical data of the BAV coexisting with suspected aortic dilatation or aneurysm from February 2012 through April 2015. A total of 124 patients were analyzed retrospectively. There were 97 males and 27 females at an anverage age of 50.35±16.26 years. According to the CTA, patients were classified into two groups: a pure BAV(without raphe) group and a BAV (with raphe) group. we recorded the aortic diameters, gender, age, and so on. ResultsOf the 124 patients, 91 (73.4%) had BAV with raphe, and 33 patients (26.6%) had pure BAV. The analysis revealed that the diameter of the annulus (23.90±3.34 mm vs. 21.74±3.46 mm, P=0.005), the sinuses of Valsalva (40.93±6.78 mm vs. 37.35±7.06 mm, P=0.022), the tubular portion of the ascending aorta (45.38±7.66 mm vs. 38.29±8.18 mm, P=0.0001), and the part of the aorta proximal to the innominate artery (34.19±4.98 mm vs. 30.23±6.62 mm, P=0.02) between patients with BAV with raphe and pure BAV had significant differences. And there was a significant difference in prevalence of dilatation of the aorta between patients with pure BAV and BAV with raphe [77/91 (84.6%) vs.18/31(58.1%), P=0.004]. Of the 91 BAV with raphe patients, we found 76 patients (83.5%) with right and left coronary cusps (R-L) fusion, 13 patients (14.3%) with right and non-coronary cusps (R-N) fusion, and 2 patients (1.2%) with left and non-coronary cusps (L-N) fusion. There was a statistical difference in the aortic root diameters between R-L fusion BAV and R-N fusion BAV. The diameter of the distal ascending aorta and proximal aortic arch between R-L and R-N fusion BAV had statistical differences. ConclusionsBAV with raphe is more common than pure BAV and is more often associated with dilatation and aneurysm of the ascending aorta. Otherwise R-L fusion BAV is associated with increased diameters of the aortic root, while R-N fusion BAV is associated with increased diameters of the distal ascending aorta and proximal arch.

    Release date:2016-11-04 06:36 Export PDF Favorites Scan
  • New-onset conduction block after transcatheter aortic valve replacement: A retrospective analysis in a single center

    ObjectiveTo investigate the new-onset conduction block after transcatheter aortic valve replacement (TAVR) and summarize the relevant experience. Methods The perioperative data of TAVR patients in the Second Hospital of Hebei Medical University from 2016 to 2023 were collected, and the new-onset incidence of conduction block after TAVR was analyzed retrospectively. ResultsThere were 352 patients of TAVR operation (256 patients of Venus-A, 69 patients of Vita-Flow, 27 patients of J-Valve), among whom 38 (10.8%) patients of new-onset postoperative block. There were 6 (1.7%) patients of new-onset postoperative grade Ⅲ atrioventricular block, including 5 (2%) patients of Venus A and 1 (1.4%) patient of Vita-Flow. Conduction function was restored in 2 patients within 14 days after surgery, and failed to be restored in 4 patients, who then received permanent pacemaker implantation in the department of cardiology. There were 27 (7.7%) patients of new left bundle branch block after surgery, including 22 (8.6%) patients of Venus-A , 4 (5.8%) patients of Vita-Flow and 1 (3.7%) patient of J-Valve; and conduction function was restored within 7 days after surgery in 23 patients, and 5 (1.4%) patients developed new right bundle branch blocks after surgery including 4 (1.5%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conclusion New-onset block is a common complication after TAVR, the new-onset rate of left bundle branch block is the highest, followed by the grade Ⅲ atrioventricular block. Mastering reasonable methods and applying appropriate strategies can also effectively reduce the new rate of postoperative conduction block and improve the overall success rate of TAVR surgery.

    Release date: Export PDF Favorites Scan
  • Short-term results of transcatheter aortic valve replacement using Venus A-Plus valve delivery system in patients with severe aortic stenosis: A retrospective cohort study

    Objective To evaluate the short-term efficacy of transcatheter aortic valve replacement (TAVR) using Venus A-Plus valve delivery system in patients with severe aortic stenosis. Methods The clinical data of patients undergoing TAVR in our hospital from August 2018 to March 2022 were collected and divided into a Venus A-PLUS and a Venus A group according to the type of valve delivery system used. The perioperative data of the two groups were compared. ResultsA total of 121 patients were included, including 70 patients in the Venus A-Plus group (45 males and 25 females with a mean age of 67.81±6.62 years), and 51 patients in the Venus A group (33 males and 18 females with a mean age of 68.25±7.01 years). All patients underwent TAVR, and the postoperative hemodynamic features (left ventricular ejection fraction, mean cross-valve pressure difference, peak flow rate) were significantly improved (P<0.05). There was no statistical difference in surgical success rate, all-cause mortality, conversion to thorax opening, midvalve placement, moderate or above perivalvular regurgitation, new left bundle branch block or new right bundle branch block between the two groups (P>0.05). Conclusion TAVR with Venus A-Plus valve delivery system in patients with severe aortic stenosis is satisfactory, safe and reliable.

    Release date: Export PDF Favorites Scan
  • Application of Imbedding Pancreaticojejunostomy in Pure Laparoscopic Pancreatico-duodenectomy

    ObjectiveTo investigate the application of imbedding pancreaticojejunostomy in pure laparoscopic pancreaticoduodenectomy. MethodsEighty-five cases of laparoscopic pancreaticoduodenectomy in our hospital from May 2014 to December 2015 were analyzed retrospectively. According with inclusion criteria and exclusion criteria, 78 cases were investigated. They were divided into pancreatic duct-to-jejunum mucosa pancreaticojejunostomy group as controlled group (n=42) and imbedding pancreaticojejunostomy (technique of duct-to-mucosa PJ with transpancreatic interlocking mattress sutures) group as modified group (n=36). The rates of pancreatic fistula, abdominal infection/abscess, bile leakage, delayed gastric emptying, gastrointestinal/intraabdominal hemorrhage, pulmonary infection, and incision infection were investigated as well as hospital stays and pancreaticojejunostomy time in two groups were compared. ResultsThe rate of pancreatic fistula especially B to C grade pancreatic fistula in the modified group was obviously lower compared with which in the controlled group (8.3% vs. 31.0%, P < 0.05), pancreaticojejunostomy time ofmodified group was significantly shortened [(35.6±12.4) min vs. (52.8±24.6) min, P < 0.05] and total operative time also shortened [(322.4±23.6) min vs. (384.2±30.2) min, P < 0.05). There were no significant difference of the rates of abdominal infection/abscess, bile leakage, delayed gastric emptying, gastrointestinal/intraabdominal hemorrhage, pulmonary infection, ?incision infection, and hospital stays (P > 0.05)]. Conciusions The type of pancreaticojejunostomy has a significant impact on the rate of pancreatic fistula after laparoscopic pancreaticoduodenectomy. Imbedding pancreaticojejunostomy can decrease the rate of pancreatic fistula after operation, and shorten the pancreaticojejunostomy time and total operative time.

    Release date: Export PDF Favorites Scan
  • Numerical simulation of a self-powered Fontan based on venturi effect

    ObjectiveTo investigate the effects of a self-powered conduit in different patients’ models who underwent extracardiac Fontan procedure.MethodsFour children who underwent extracardiac Fontan procedure in Shanghai Children's Medical Center from 2011 to 2017 year were selected. Venae cavae and pulmonary arteries were reconstructed using Mimics 19.0®. In silico, a venturi conduit was introduced to the anastomosis of venae cavae and pulmonary artery. Then computational fluid dynamics simulation was performed using patients’ clinical data.ResultsWhen inferior venae cavae were directly to or to the left of superior venae cavae, the venturi conduit could assist the return of venous blood and reduce the pressures of venae cavae about 0.5 mm Hg. And the pressure differences between venae cavae and pulmonary arteries were about –0.7 mm Hg, which suggested that the conduit could generate right ventricle-like effect.ConclusionThe venturi conduit can reduce the pressure of venae cavae, increase pulmonary circulation flow and improve Fontan hemodynamics.

    Release date:2019-08-12 03:01 Export PDF Favorites Scan
  • Short-term clinical efficacy of one-stop TAVR+PCI in the treatment of patients with aortic valve disease and coronary heart disease

    ObjectiveTo analyze the short-term clinical efficacy and prognosis of one-stop transcatheter aortic valve replacement (TAVR)+percutaneous coronary intervention (PCI) in the treatment of aortic valve disease with coronary heart disease. MethodsThe clinical data of patients with aortic valve disease complicated with coronary heart disease who underwent one-stop TAVR+PCI treatment at the Department of Cardiovascular Surgery, the Second Hospital of Hebei Medical University from January 2018 to June 2023 were retrospective analyzed. The preoperative and postoperative clinical data were compared, and 1-month follow-up results were recorded. ResultsA total of 37 patients were enrolled, including 22 males and 15 females, with an average age of 69.14±6.47 years. Thirty-six patients recovered and were discharged after the surgery, and 1 (2.7%) patient died during the surgery. Self-expanding TAVR valves were implanted through the femoral artery in all patients. One coronary artery was opened by PCI in 35 (94.6%) patients, and two coronary arteries were opened by PCI in 2 (5.4%) patients. All PCI opened arteries had a stenosis>70%. During the postoperative hospitalization, the complications included pulmonary infection in 11 (30.6%) patients, severe pneumonia in 10 (27.8%) patients, liver function injury in 14 (38.9%) patients, renal function injury in 5 (13.9%) patients, cerebral infarction in 1 (2.8%) patient, atrial fibrillation in 1 (2.8%) patient, ventricular premature beats in 2 (5.6%) patients, atrioventricular block in 2 (5.6%) patients, and complete left bundle branch block in 5 (13.9%) patients. The median postoperative ventilation assistance time was 12.0 (0.0, 17.0) h, the ICU monitoring time was 1.0 (0.0, 2.0) d, and the postoperative hospitalization time was 5.0 (4.0, 7.0) d. There was a significant improvement in the New York Heart Association cardiac function grading after surgery (P<0.001). After surgery, there were 21 (58.3%) patients had minor perivalve leakage, 6 (16.7%) patients had minor to moderate perivalve leakage, and no moderate or above degree of perivalve leakage. After one month of postoperative follow-up, 36 patients showed significant improvement in heart function. There were no patients with recurrent acute coronary syndrome, re-PCI, or cardiovascular system disease related re-hospitalization. ConclusionThe one-stop TAVR+PCI treatment for patients with aortic valve disease and coronary heart disease can obtain satisfactory short-term clinical efficacy, which is worth further trying and studying.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next