Objective To develop an evaluation tool for the screening of high risk population for oral complications in critically ill patients, which can be performed accurately and scientifically. Methods Basing on the related foreign oral assessment scale, combined with the method of brainstorming, expert consultation, method of clinical status and so on, the item pool of the assessment scale was determined. Five nursing experts and two oral experts assessed the content validity and 50 ICU nurses were tested. Then, the screening accuracy of the assessment scale was proved by application in 100 critically ill patients selected randomly. Results The Cronbach’s a coefficient of final version of the High Risk Assessment Scale for Oral Complications in Critically Ill Patients (including seven parts contents of oral health assessment and oral pH value test) was 0.815, the content validity index (Sr-CVI/Ave) was 0.932. The results of 50 nurses to the 91.2% assessment items of the assessment scale were very important and important. For screening related indicators of oral complications in high-risk patients, the sensitivity of the assessment scale was 97.53%, the specificity was 94.11%, the positive predictive value was 98.75%, the negative predictive value was 88.89%, and the crude agreement was 95%. Conclusion There are good reliability, validity and a high accuracy of screening test in the High Risk Assessment Scale for Oral Complications in Critically Ill Patients. It can be used for screening patients at high risk for oral complications in critically ill patients, and help clinical nurses to complete the oral health status of the critically ill patients quickly.
ObjectiveTo evaluate the reliability,validity and feasibility of a patient-reported outcomes (PRO) scale in the subjects with respiratory failure. Methods364 patients with chronic respiratory failure and 97 healthy subjects were face-to-face interviewed by well-trained investigators,and the data of respiratory failure -PRO instrument were collected. The psychometric performance such as reliability,validity,responsiveness and clinical feasibility in the respiratory failure -PRO instrument was evaluated. ResultsThe Cronbach's alpha coefficient of the respiratory failure -PRO instrument and each dimension were greater than 0.7. Factor analysis showed that the instrument had good construct validity. The scores of each of the facets and total scores between the patients and the healthy subjects were different. The recovery rate and the efficient rate of the questionnaire were more than 95%,and the time required to complete a questionnaire was within 15 minutes,indicating that the scale had a high clinical feasibility. ConclusionThe respiratory failure -PRO instrument has good reliability,validity,responsiveness and clinical feasibility.
Objective To evaluate the reliability and validity of IBS-QOL scale in irritable bowel syndrome (IBS) patients. Methods IBS-QOL scale was applied to survey the quality of life of 123 IBS patients. The split-half and internal consistency method were used to evaluate the reliability, and with the construct method to evaluate the validity. Results The split-half reliability was 0.86. Cronbach’s α-coefficient of all domains was between 0.71 and 0.89 except body image and food avoidance; In the correlation analysis, the correlations between items and its subscale structure were above 0.60 (except interference with activity), but there were no correlations between items and other subscale structure. Eight components from factorial analysis were in accordance with theoretical structure.The cumulative contribution rate was 72.7%. Conclusions The reliability and validity of IBS-QOL scale are acceptable. It might be useful for us to assess the QOL of IBS patients in China.
Measurement properties studies of patient-reported outcome measures (PROMs) aims to validate the measurement properties of PROMs. In the process of designing and statistical analysis of these measurement properties studies, bias will occur if there are any defects, which will affect the quality of PROMs. Therefore, the COSMIN (consensus-based standards for the selection of health measurement instruments) team has developed the COSMIN risk of bias (COSMIN-RoB) checklist to evaluate risk of bias of studies on measurement properties of PROMs. The checklist can be used to develop systematic reviews of PROMs measurement properties, and for PROMs developers, it can also be used to guide the research design in the measurement tool development process for reducing bias. At present, similar assessment tools are lacking in China. Therefore, this article aims to introduce the primary contents of COSMIN-RoB checklist and to interpret how to evaluate risk of bias of the internal structure studies of PROMs with examples.
ObjectiveTo evaluate the reliability and validity of the instrument of clinical applicability of guidelines (version 2.0). MethodsThe experts of domestic medical institutions were investigated by questionnaire, and the instrument of clinical applicability of guidelines (version 2.0) were evaluated the guidelines for the diagnosis and treatment of tinea mantis and tinea pedis (revised edition 2017) and the guidelines for the diagnosis and treatment of cerebral hemorrhage in China (2019). Using Cronbach's α coefficient and Spearman-Brown coefficient to evaluate the inherent reliability and split-half reliability. The content validity was evaluated by calculating the content validity index of the item level and the adjusted Kappa value. The correlation coefficient between each item and the dimension and the hypothesis test were used to evaluate the convergent and discriminant validity. The structural validity was evaluated by using structural equation model to evaluate the structural validity of the tool. ResultsThe Cronbach's α coefficient and Spearman-Brown coefficient of the instrument of clinical applicability of guidelines (version 2.0) were both greater than 0.7, the content validity index (S-CVI/Ave) were more than 0.8, the success rates of convergent were 100%, and the success rates of discriminant validity calibration were 100% and 96%. In the second-order confirmatory factor analysis model, the χ2/ df were less than 3, the fitting index (CFI), the goodness of fit index (GFI) and the adjustment goodness of fit index (AGFI) were all greater than 0.9. The root mean square residual (RMR) were all less than 0.05, and approximate error root mean square (RMSEA) were less than 0.09. The P value of RESEA hypothesis test were more than 0.05. ConclusionThe instrument of clinical applicability of guidelines (version 2.0) has good reliability and validity, which can be further verified in practical application in the future.
Objective To primarily test the reliability and validity of the Kashin-Beck Disease (KBD) affected big joints function assessing system for adult Tibetans in Rangtang County. Method From June to July 2009, 142 KBD patients were investigated with the function assessing system in Rangtang County of Ngawa. Cronbach’s α coefficient was calculated to estimate internal consistency reliability. Pearson’s r for the correlation of the items with the total score of the scale was computed to test the internal validity. Principal component factor analysis with varimax rotation analysis was conducted to explore construct validity. Result Both the response and complete rates of the scale were 100%. The time for completing the scale was 7.8±3.4 minutes. Cronbach’s α was 0.857, which revealed satisfactory internal consistency reliability. Pearson correlation analysis revealed significant correlation between the scores of each item and the total score of the scale (Plt;0.05). Pearson’s r value of each item was more than 0.4, only except the items of “sitting with legs crossed” and “standing at attention”. The principal factor analysis extracted three latent factors explaining 68.1% of the variation together. The latent factors weights of the items were over 0.4 except the items of “standing at attention”, "taking food” and “wiping after defecation”. Conclusion The reliability and validity of KBD affected big joints function assessing system for adult Tibetans in Rangtang County was good in this primary test, the function assessing system has to be widely applied and further assessed among Tibetans suffered with KBD, in order to provide a standard evaluation criterion in KBD integrate control.
Objective We aimed to develop a self-management assessment scale for children with epilepsy and test its reliability and validity. Methods A research group was established, and the items were revised through literature review, group discussion and pre-investigation, and 280 patients with epilepsy in children were included, and the reliability and validity of the scale were tested. Results 28 items in 4 dimensions were developed to form the scale, namely, knowledge and belief of diseases and medication, compliance of medication and treatment, self-efficacy of medication and obstacles of medication. Confirmatory factor analysis extracted four common factors with characteristic roots greater than 1, and the cumulative variance explanation rate was 65.639%. The factor load of all items is > 0.5. The overall Cronbach’s alpha is 0.880, and the coefficients in seven measurement dimensions are all greater than 0.8. Conclusion The self-management assessment scale for children’s epilepsy drugs has good reliability and validity, and can provide a measuring tool for the drug management of children’s epilepsy diseases.
Evidence synthesis is the process of systematically gathering, analyzing, and integrating available research evidence. The quality of evidence synthesis depends on the quality of the original studies included. Validity assessment, also known as risk of bias assessment, is an essential method for assessing the quality of these original studies. Currently, there are numerous validity assessment tools available, but some of them lack a rigorous development process and evaluation. The application of inappropriate validity assessment tools to assessing the quality of the original studies during the evidence synthesis process may compromise the accuracy of study conclusions and mislead the clinical practice. To address this dilemma, the LATITUDES Network, a one-stop resource website for validity assessment tools, was established in September 2023, led by academics at the University of Bristol, U.K. This Network is dedicated to collecting, sorting and promoting validity assessment tools to improve the accuracy of original study validity assessments and increase the robustness and reliability of the results of evidence synthesis. This study introduces the background of the establishment of the LATITUDES Network, the included validity assessment tools, and the training resources for the use of validity assessment tools, in order to provide a reference for domestic scholars to learn more about the LATITUDES Network, to better use the appropriate validity assessment tools to conduct study quality assessments, and to provide references for the development of validity assessment tools.
Objective To evaluate the reliability and validity of the Chinese version of the Amsterdam Preoperative Anxiety and Information Scale (APAIS) in preoperative anxiety in patients with local anesthesia. Methods From May to December 2020, a convenient sampling method was used to conduct an APAIS questionnaire survey on patients undergoing percutaneous renal biopsy in the Department of Nephrology, West China Hospital, Sichuan University, and the reliability and validity of the scale were analyzed. ResultsA total of 460 questionnaires were distributed and 444 valid questionnaires were returned, with a valid response rate of 96.5%. The Cronbach α of APAIS was 0.896, the Guttman split-half reliability was 0.811, and the content validity index was 0.891. The model fit was 12.122 for the chi-square fit index/degree of freedom, 0.916 for the goodness-of-fit index, 0.902 for the value-added fit index, 0.079 for the root mean square error of approximation, and 0.946 for the comparative fit index. The APAIS anxiety subscale score was positively correlated with the 7-item Generalized Anxiety Disorder Scale score (r=0.518, P<0.001). Conclusion The APAIS has good reliability and validity for evaluating the level of preoperative anxiety in patients with local anesthesia, but the application of the scale in other conditions requires further testing.
ObjectiveTo develop a patient satisfaction evaluation scale for day surgery and test its reliability and validity, so as to provide a scientific and effective tool for day surgery patient satisfaction assessment.MethodsThe literature review method was used to form an entry pool, and the initial version of the scale was formed in conjunction with the expert review method. And then a preliminary survey was conducted to obtain the tentative version of the scale. Finally, 290 day surgery patients discharged between June 15th and July 15th, 2019 were selected to accomplish a survey to check the reliability and validity of the scale.ResultsFinally, a day surgery patient satisfaction evaluation scale was formed, containing 3 stages (pre-hospital, hospitalization, and postdischarge follow-up), 3 dimensions (medical staff evaluation, medical service evaluation, and environment and process evaluation), and 40 items. After the formal survey, the overall Cronbach’s α coefficient of the scale was 0.980, the Spearman-Brown coefficient was 0.933, the Guttman’s half-coefficient was 0.932, and the content validity was 0.87-1.00.ConclusionThe day surgery patient satisfaction evaluation scale was proven good reliability and validity, which can be used as a measurement tool for day surgery patients and applied to clinical practice.