find Keyword "无创呼吸机" 7 results
  • Clinical analysis of invasive mechanical ventilation with bilevel positive airway pressure non-invasive ventilator

    Objective To study the clinical feasibility of invasive mechanical ventilation with bilevel positive airway pressure(BiPAP) non-invasive ventilator in the stable patients needing prolonged mechanical ventilation.Methods Eleven patients with respiratory failure admitted in intensive care unit(ICU)of our department,who needed prolonged mechanical ventilation,between Jun 2004 and Nov 2007 were enrolled in the study and followed until death or Jan 2008.The arterial blood gas analysis data,length of stay(LOS),LOS after changing to BiPAP non-invasive ventilator(Synchrony,Harmony,RESPIRONICS,VPAP III ST-A,RESMED),survival time after discharge(or fulfilled the discharge standards) were reviewed retrospectively.Results The settings of inspiratory pressure,expiratory pressure and respiratory rate of non-invasive ventilation were 21.3 (16-26) cm H2O,4 cm H2O,and 16 min-1,respectively.The LOS (or up to the discharge standard) was (91.5±50.2) days.The LOS (or up to the discharge standard) after changing to BiPAP ventilator was (23.5±12.2) days.The mean survival time after discharge (or up to the discharge standard) was (353.1±296.5) days.Four patients were still alive up to the end of the study.The arterial pH,PaCO2,PaO2,and SaO2 were not significant different before and after changing to BiPAP ventilator.Conclusion The mechanical ventilation with BiPAP non-invasive ventilator via tracheotomy tube is an alternative choice for stable patients needing prolonged mechanical ventilation.

    Release date:2016-09-14 11:56 Export PDF Favorites Scan
  • Nursing Care of Acute Left Heart Failure Patients with Non-invasive Positive Pressure Ventilation

    目的 加强对急性左心功能衰竭患者的无创呼吸护理,确保救治安全和提高治疗效果。 方法 对2011年1月-9月收治的急性左心功能衰竭且应用无创呼吸机治疗的57例患者,采取相关应对措施进行系统性护理干预。 结果 5例患者因病情加重改行气管插管,52例经使用无创呼吸机治疗后,其病情稳定转出心脏病监护病房。治疗中2例配合较差,7例出现腹胀,2例发生鼻面部压迫性损伤。 结论 对症有效的护理干预措施对救治急性左心功能衰竭患者生命,提升无创呼吸的舒适感和医从性,降低相关并发症有积极作用。

    Release date:2016-09-08 09:16 Export PDF Favorites Scan
  • 无创呼吸机在急性重症胰腺炎护理中的应用

    【摘要】 目的 总结无创呼吸机在急性胰腺炎合并呼吸衰竭患者中的疗效及护理体会。 方法 2009年1月-2010年8月,对22例急性胰腺炎合并呼吸衰竭患者使用无创呼吸机、双水平气道正压通气模式救治。救治过程中,在系统的呼吸治疗基础上,给予细致的专科护理。 结果 17例首选无创通气的患者中6例痊愈;5例首选有创通气后行无创呼吸机序贯治疗的患者均痊愈出院。 结论 无创呼吸机对急性胰腺炎合并急性呼吸窘迫综合征的疗效有限;对有创通气后的无创序贯治疗有较好疗效。

    Release date:2016-09-08 09:25 Export PDF Favorites Scan
  • Physiological Effects of Oxygen Injection Site during Noninvasive Positive Pressure Ventilation

    Objective To investigate the physiological effects of different oxygen injection site on ventilatory status and oxygenation during noninvasive positive pressure ventilation ( NPPV) with portable noninvasive ventilators. Methods A prospective crossover randomized study was performed. Oxygen injection site was randomized into the outlet of the ventilator, the connection site between mask and circuit, and the mask under the condition of leak port immobilized in the mask. Oxygen flow was retained in the baseline level at the initial 5 to 10 minutes, and adjusted to obtain arterial oxygen saturation measured by pulse oximetry ( SpO2 ) ranging from 90% to 95% after SpO2 remains stable. SpO2 at the initial 5 to 10 minutes, oxygen flow, ventilatory status, oxygenation, hemodynamics and dyspnea indexes at0. 5 hour, 1 hour, and 2 hours of NPPV were compared between different oxygen injection sites. Results 10 patients were recruited into the study. Under the condition of the same oxygen flow, SpO2 with oxygen injection site in the outlet of the ventilator was significantly higher than that with oxygen injection site in the connection site between mask and circuit [ ( 98.9 ±0.9) % vs. ( 96.9 ±1.1) % , P =0. 003] , whereas SpO2 with oxygen injection site in the connection site between mask and circuit was significantly higher than that with oxygen injection site in the mask [ ( 96.9 ±1.1) % vs. ( 94.1 ±1.6) %, P = 0.000] . Oxygen flow with oxygen injection site in the mask was statistically higher than that with oxygen injection site at other sites ( P lt; 0.05) . Arterial oxygen tension/ oxygen flow with oxygen injection site in the outlet of the ventilator was significantly higher than that with oxygen injection site in the connection site between mask and circuit ( 67.9 ±31.1 vs. 37.0 ±15.0, P =0.007) , and than that with oxygen injection site in the mask ( 67.9 ± 31.1 vs. 25.0 ±9.1, P = 0.000) . pH, arterial carbon dioxide tension, hemodynamics and dyspnea indexes were not significantly different between different oxygen injection sites ( P gt; 0.05) .Conclusions When portable noninvasive ventilator was applied during NPPV, oxygen injection site significantly affects improvement of oxygenation, and shows a trend for affecting ventilatory status and work of breathing. When the leak port was immobilized in the mask, the nearer oxygen injection site approaches the outlet of the ventilator, the more easily oxygenation is improved and the lower oxygen flow is demanded.

    Release date:2016-09-13 03:53 Export PDF Favorites Scan
  • 无创呼吸机治疗肺性脑病使用右美托咪定的疗效影响观察

    目的观察右美托咪定在肺性脑病患者使用无创呼吸机时对疗效的影响。 方法选取2013年6月-2014年5月收治的52例使用无创呼吸机的慢性阻塞性肺疾病患者作为观察对象,以随机数字法将患者分为观察组(27例)和对照组(25例)。两组患者均同时使用伟康BiPAP synchrony型无创呼吸机治疗,采用压力支持/控制模式。观察组在治疗期间给予盐酸右美托咪定镇静;对照组在患者有意识障碍时使用四肢约束装置、家人劝阻、头部固定等方法,24 h观察期内不使用任何镇静药物。观察两组患者在动脉血气指标、舒适度评价及无创呼吸机使用依从性方面的区别。 结果两组患者在治疗2 h时pH值、动脉血二氧化碳分压(PaCO2)、动脉血氧分压指标比较差异均无统计学意义(P > 0.05),治疗12、24 h后pH值、PaCO2比较差异有统计学意义(P < 0.05),观察组优于对照组。使用无创呼吸机后观察组舒适度维持在较高水平,对照组舒适度明显下降,两组患者舒适度评分比较差异有统计学意义(P < 0.05)。观察组患者使用无创呼吸机的依从性良好率(88.89%)优于对照组(56.00%),差异有统计学意义(P < 0.05)。 结论右美托咪定可改善患者使用无创呼吸机时的舒适度及治疗依从性,从而提高对肺性脑病的临床疗效。

    Release date:2016-10-28 02:02 Export PDF Favorites Scan
  • 无创呼吸机专用面部减压垫的设计

    Release date:2017-09-22 03:44 Export PDF Favorites Scan
  • A bench study of the auto adjusted triggering in noninvasive mechanical ventilators

    Objective To evaluate the effect of auto adjusted triggering mechanism on the triggering balance of sensitivity and anti-interference in non invasive ventilator field. Methods Taking the breathing simulator as the experimental platform, for the same ventilator, the experiments of "automatic adjustment mode" and "manual adjustment mode" were carried out in a self-control manner, comparing the sensitivity and anti-interference indexes of the experimental group and the control group in the triggering stage. The results were statistically analyzed. Results In case of large air leakage, for ventilator of "A40", the group of "automatic adjustment mode" presented auto-triggered cycle and the group of "manual adjustment mode" (the inspiratory trigger sensitivity was adjusted to 5 to 9 L/min) could provide breathing assistance ventilation. While for ventilator of "VENT", both the group of "automatic adjustment mode" and the group of "manual adjustment mode" (the inspiratory trigger sensitivity was adjusted to 1 to 8 arbitrary unit) appear auto-triggered cycle. In case of medium air leakage, for ventilator of "A40", the trigger delay time, trigger pressure and trigger work of the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 3 to 5 L/min) were significantly less than those of the "automatic adjustment mode" group, and the trigger delay time, trigger work of the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 8 to 9 L/min) were significantly higher than those of the "automatic adjustment mode" group; While for ventilator of "VENT", compared with the inspiratory trigger sensitivity of the "automatic adjustment mode" group and the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 4 arbitrary unit), the trigger delay time, trigger pressure and trigger work were not statistically significant. In case of small air leakage, for ventilator of "A40", the trigger delay time and trigger work of the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 2 to 6 L/min) were significantly less than those in the "automatic adjustment mode" group, and the trigger pressure of "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 2 to 5 L/min and 7 L/min) was significantly lower than that of "automatic adjustment mode" group. While for ventilator of "VENT", the trigger delay time, trigger pressure and trigger work of the "manual adjustment" group (the inspiratory trigger sensitivity was adjusted to 1 to 2 arbitrary unit) were less than those of the experimental group, and they were statistically significant. Conclusions In case of large air leakage, ventilator of "VENT" can not provide breathing assistance ventilation no matter which inspiratory trigger mode. While ventilator of "A40" should be used the "manual adjustment mode", and adjust the inspiratory trigger sensitivity to the less sensitive arbitrary unit to increase its performance of anti-interference. In case of medium air leakage, for both ventilator of "A40" and ventilator of "VENT", it is better to use "automatic adjustment" mode for breathing assistance ventilation. In case of small air leakage, for both ventilator of "A40" and ventilator of "VENT", it is better to use "manual adjustment" mode for breathing assistance ventilation and we should adjust the inspiratory trigger sensitivity to the higher sensitive arbitrary without auto-triggered cycle.

    Release date: Export PDF Favorites Scan