west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "机器人辅助手术" 16 results
  • Comparison of accuracy between robot-assisted and fluoroscopy-guided percutaneous pedicle screw placement for treatment of lumbar spondylolisthesis

    Objective To explore the clinical application value of the spinal robot-assisted surgical system in mild to moderate lumbar spondylolisthesis and evaluate the accuracy of its implantation. Methods The clinical data of 56 patients with Meyerding grade Ⅰ or Ⅱ lumbar spondylolisthesis who underwent minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) between January 2017 and December 2017 were retrospectively analysed. Among them, 28 cases were preoperatively planned with robotic arm and percutaneous pedicle screw placement according to preoperative planning (group A); the other 28 cases underwent fluoroscopy-guided percutaneous pedicle screw placement (group B). There was no significant difference in gender, age, body mass index, slippage type, Meyerding grade, and surgical segmental distribution between the two groups (P>0.05). The screw insertion angle was measured by CT, the accuracy of screw implantation was evaluated by Neo’s criteria, and the invasion of superior articular process was evaluated by Babu’s method. Results One hundred and twelve screws were implanted in the two groups respectively, 5 screws (4.5%) in group A and 26 screws (23.2%) in group B penetrated the lateral wall of pedicle, and the difference was significant (χ2=9.157, P=0.002); the accuracy of nail implantation was assessed according to Neo’s criteria, the results were 107 screws of degree 0, 3 of degree 1, 2 of degree 2 in group A, and 86 screws of degree 0, 16 of degree 1, 6 of degree 2, 4 of degree 3 in group B, showing significant difference between the two groups (Z=4.915, P=0.031). In group B, 20 (17.9%) screws penetrated the superior articular process, while in group A, 80 screws were removed from the decompression side, and only 3 (3.8%) screws penetrated the superior articular process. According to Babu’s method, the degree of screw penetration into the facet joint was assessed. The results were 77 screws of grade 0, 2 of grade 1, 1 of grade 2 in group A, and 92 screws of grade 0, 13 of grade 1, 4 of grade 2, 3 of grade 3 in group B, showing significant difference between the two groups (Z=7.814, P=0.029). The screw insertion angles of groups A and B were (23.5±6.6)° and (18.1±7.5)° respectively, showing significant difference (t=3.100, P=0.003). Conclusion Compared to fluoroscopy-guided percutaneous pedicle screw placement, robot-assisted percutaneous pedicle screw placement has the advantages such as greater accuracy, lower incidence of screw penetration of the pedicle wall and invasion of the facet joints, and has a better screw insertion angle. Combined with MIS-TLIF, robot-assisted percutaneous pedicle screw placement is an effective minimally invasive treatment for lumbar spondylolisthesis.

    Release date:2018-10-31 09:22 Export PDF Favorites Scan
  • 机器人辅助纵隔肿瘤手术中国专家共识(2019 版)

    Release date:2020-02-26 04:33 Export PDF Favorites Scan
  • Short-term effects of Da Vinci robot Nissen fundoplication in the treatment of refractory gastroesophageal reflux disease

    ObjectiveTo investigate the short-term effects of Da Vinci robot-assisted Nissen fundoplication in the treatment of refractory gastroesophageal reflux disease (rGERD), and to evaluate the safety and efficacy of its surgical treatment.MethodsA total of 40 patients with rGERD treated by Da Vinci robot-assisted surgery from October 2016 to November 2019 in our hospital were collected. There were 23 males and 17 females at age of 34-76 (61±23) years. The related clinical data were retrospectively analyzed, and the operation skills of Da Vinci robot-assisted Nissen fundoplication with rGERD were summarized.ResultsThere was no perioperative death or serious complication such as esophagogastric fistula. Postoperative reflux symptoms were significantly improved. DeMeester scores after surgery (39.79±35.01 points vs. 2.61±2.40 points, P=0.029), lower esophageal sphincter pressure (8.74±7.21 mm Hg vs. 24.56±8.76 mm Hg, P=0.020), integrated relaxation pressure (7.29±7.21 mm Hg vs. 16.49±9.99 mm Hg, P=0.023), distal contractile integral (600.49 ± 665.30 mm Hg·s·m vs. 510.99 ± 580.60 mm Hg·s·m, P=0.042), GERD-Q scale score (12.98±2.39 points vs. 7.59±1.11 points, P=0.033) were significantly improved compared with those before surgery. Postoperative dysphagia was found in 2 patients. And dysphagia was alleviated after diet adjustment and other treatments.ConclusionDa Vinci robot-assisted Nissen fundoplication is a safe and effective treatment for rGERD.

    Release date:2020-03-25 09:52 Export PDF Favorites Scan
  • Chinese expert consensus on robot-assisted pulmonary resections

    Robotic surgery system has been widely used in various types of pulmonary resections. With the unremitting efforts of Chinese thoracic surgeons, the quantity and quality of robotic pulmonary resections in China have reached a remarkable level. With the development and rapid promotion of this technology, the popularity of robotic surgery is also increasing. In order to standardize the clinical practice, guarantee the quality of treatment and promote the development of robotic pulmonary resections, the Committee of Thoracic Surgery, Doctor Society of Medical Robotics, Chinese Medical Doctor Association organized relevant domestic experts to formulate the consensus of Chinese clinical experts on robot-assisted lung cancer surgery.

    Release date:2020-10-30 03:08 Export PDF Favorites Scan
  • Clinical application of three-dimensional computed tomography bronchography and angiography in robotic lung segmentectomy

    ObjectiveTo explore the clinical value of three-dimensional computed tomography bronchography and angiography (3D-CTBA) in robotic lung segmentectomy.MethodsA non-randomized control study was performed and continuously enrolled 122 patients who underwent robotic lung segmentectomy in our hospital from January 2019 to January 2020. 3D-CTBA was performed before operations in 53 patients [a 3D-CTBA group, including 18 males, 35 females, with a median age of 52 (26-69) years] and not performed in the other 69 patients [a traditional group, including 23 males, 46 females, with a median age of 48 (30-76) years]. The clinical data of the patients were compared between the two groups.ResultsAll the patients were successfully completed the surgery and recovered from hospital, with no perioperative death. The baseline characteristics of the patients were not significantly different between the two groups (P>0.05). No significant difference was found in the operative time [120 (70-185) min vs. 120 (45-225) min, P=0.801], blood loss [50 (20-300) mL vs. 30 (20-400) mL, P=0.778], complications rate (17.0% vs. 11.6%, P=0.162), postoperative hospital stay [7 (4-19) d vs. 7 (3-20) d, P=0.388] between the two groups. In the 3D-CTBA group, 5 (9.4%) patients did not find nodules after segmentectomy, and only 1 (1.9%) of them needed lobectomy, but in the traditional group, 8 (11.6%) patients did not find nodules and had to carry out lobectomy, the difference was statistically significant (P<0.05). The follow-up time was 10 (1-26) months, and during this period, there was no recurrence, metastasis or death in the two groups.Conclusion3D-CTBA is helpful for accurate localization of nodules and reasonable surgical planning before operations, and reducing wrong resections in segmentectomy, without increasing the operation time, blood loss and complications. It is safe and effective in anatomical lung segmentectomy.

    Release date:2020-10-30 03:08 Export PDF Favorites Scan
  • Efficacy comparison between robot-assisted and conventional mitral valve surgery: A systematic review and meta-analysis

    ObjectiveThrough comparing the therapeutic efficacy of robot-assisted surgery (RS) and conventional surgery (CS) for mitral valve disease by meta-analysis to guide the choice of clinical operation.MethodsDatabases including The Cochrane Library, PubMed, EMbase, China National Knowledge Infrastructure (CNKI), China Biology Medicine disc (CBMdisc) and Wanfang Database were searched by computer from inception to June 2020. The literature of efficacy comparison between RS and CS was collected. Two reviewers independently screened the literature according to inclusion and exclusion criteria, extracted the data, and evaluated the quality of the literature. Meta-analysis was performed using RevMan 5.4 software.ResultsWe identified 11 studies of RS versus CS with 4 330 patients. Among them, 2 212 patients underwent RS and 2 118 underwent CS. Meta-analysis demonstrated that compared with the CS, RS had longer cross-clamp time (MD=25.00, 95%CI 15.04 to 34.95, P<0.000 01), cardiopulmonary bypass time (MD=44.11, 95%CI 29.26 to 58.96, P<0.000 01) and operation time (MD=46.40, 95%CI 31.55 to 61.26, P<0.000 01). However, ICU stay (MD=–22.13, 95%CI –31.88 to –12.38, P<0.000 01) and hospital stay (MD=–1.81, 95%CI –2.69 to –0.92, P<0.000 01) were significantly shorter in the RS group; and the incidences of blood transfusion (OR=0.38, 95%CI 0.16 to 0.89, P=0.03) and complications (OR=0.73, 95%CI 0.57 to 0.94, P=0.01) were significantly lower in the RS group.ConclusionAlthough RS has a longer operation time than CS, it has less damage, less bleeding, faster recovery and better curative efficacy.

    Release date:2020-12-07 01:26 Export PDF Favorites Scan
  • The effects of robotic versus thoracoscopic lobectomy on body trauma and lymphocyte subsets in patients with non-small cell lung cancer

    ObjectiveTo investigate the effects of robotic versus thoracoscopic lobectomy on body trauma and lymphocyte subsets in patients with non-small cell lung cancer (NSCLC).MethodsThe clinical data of 120 patients with NSCLC who underwent lobectomy in the same operation group at the same period were collected and divided into a robot group (n=60) and a thoracoscope group (n=60) according to different surgical methods. The operation time, intraoperative blood loss, postoperative drainage time, drainage volume, postoperative hospital stay, complication rate, pain visual analogue scale (VAS) and other perioperative indicators were recorded in the two groups. Inflammatory markers: C-reactive protein (CRP), interleukin-6 (IL-6) and lymphocyte subsets (CD3+, CD4+, CD8+, CD4+/CD8+) levels were measured before and 1 d, 3 d after surgery. The effects of the two surgical methods on the body trauma and lymphocyte subsets were compared.ResultsThe operation time, intraoperative blood loss, postoperative drainage time, drainage volume and VAS of the robot group were lower than those of the thoracoscope group, and the differences were statistically significant (P<0.05). On the 1st day after surgery, IL-6 of the thoracoscope group was higher than that of the robot group, while CD3+, CD4+ and CD8+ were lower than those of the robot group, with statistically significant differences (P<0.05).ConclusionCompared with thoracoscopic lobectomy, robotic lobectomy has less trauma, less inflammatory response, faster recovery, less inhibitory effect on lymphocyte subsets, and has clinical advantages.

    Release date:2021-03-19 01:41 Export PDF Favorites Scan
  • Robot-assisted bilateral internal mammary arteries harvesting for off-pump coronary artery bypass grafting with 5 grafts by minimally invasive small incision: A case report

    ObjectiveTo introduce the method and preliminary experience of robot-assisted bilateral internal mammary arteries (BIMA) harvesting for off-pump coronary artery bypass grafting (OPCAB) with 5 grafts via left anterolateral minithoracotomy.MethodsBIMA were harvested using the da Vinci robotic surgical system, and the right internal mammary artery (RIMA) was pulled out of the thoracic cavity through right second intercostal space. Intercepting the distal part of the RIMA for the BIMA composite Lima-Rima Y graft and anastomosing the great saphenous vein with remaining RIMA end to end. The Y graft anastomosed with left anterior descending (LAD) branch and diagonal branches (DIAG), artery-vein graft sequentially anastomosed with blunt round branch, left ventricular posterior branch and posterior descending branch.ResultsThe operation succeeded without hemodynamic instability and intra aortic balloon pump (IABP) implantation or cardiopulmonary bypass. The blood flow of Y graft was 24 mL/min, and the blood flow of artery-vein graft was 30 mL/min. Ventilator assistance time was 35 hours, ICU staying time was 62 hours, and postoperative myocardial enzymes increased temporarily. Postoperative coronary CTA showed that all the grafts were patency, and cardiac ultrasound indicated that the heart function was normal. The patient cured and discharged from hospital 7 days after operation.ConclusionRobot-assisted bilateral internal mammary artery harvesting for OPCAB with 5 grafts via left anterolateral minithoracotomy is feasible, which can achieve complete revascularization.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
  • Robot-assisted joint arthroplasty—An emerging technology of the present and the future

    ObjectiveTo review and evaluate the research progress of the robot-assisted joint arthroplasty.MethodsThe domestic and foreign related research literature on robot-assisted joint arthroplasty was extensively consulted. The advantages, disadvantages, effectiveness, and future prospects were mainly reviewed and summarized.ResultsThe widely recognized advantages of robot-assisted joint arthroplasty are digital and intelligent preoperative planning, accurate intraoperative prosthesis implantation, and quantitative soft tissue balance, as well as good postoperative imaging prosthesis position and alignment. However, the advantages of effectiveness are still controversial. The main disadvantages of robot-assisted joint arthroplasty are the high price of the robot system, the prolonged operation time, and the increased radioactive damage of the imaging-dependent system.ConclusionCompared to traditional arthroplasty, robot-assisted joint arthroplasty can improve the accuracy of the prosthesis position and assist in the quantitative assessment of soft tissue tension, and the repeatability rate is high. In the future, further research is needed to evaluate the clinical function and survival rate of the prosthesis, as well as to optimize the robot system.

    Release date: Export PDF Favorites Scan
  • Robot-assisted minimally invasive coronary artery bypass in treating multi-vessel coronary artery disease: A retrospective study in a single center

    ObjectiveTo evaluate the early and mid-term results of robot-assisted coronary artery bypass grafting (RACAB) in the treatment of multi-vessel coronary artery disease (MV-CAD). Methods Patients with MV-CAD who underwent RACAB from April 2018 to December 2021 in our hospital were included. Patients who underwent hybrid coronary revascularization (HCR) which combined RACAB with percutaneous coronary intervention were allocated to a HCR-RACAB group, and patients who underwent multi-vessel RACAB were allocated to a MV-RACAB group. Perioperative and follow-up data were collected and compared between the two groups. Results A total of 102 patients were included, including 81 males and 21 females with a mean age of 61.7±10.8 years. Two (2.0%) patients were transferred to conventional CABG due to sudden ventricular fibrillation and pleura adhesion. In the remaining 100 patients who underwent RACAB, 100 left internal mammary arteries (LIMA) and 46 right internal mammary arteries (RIMA) were harvested with a 100.0% success rate. Besides, all patients undergoing RACAB achieved LIMA/RIMA-left anterior descending branch reconstruction, with an average number of 2.5±0.6 target vessels revascularized by stent or graft. One patient had perioperative myocardial infarction with an outcome of death. The incidence of major perioperative adverse events was 1.0%. There was no perioperative stroke or re-sternotomy for hemostasis. The mean follow-up time was 28.2 months, with a follow-up rate of 99.0% and an overall major adverse cardiac and cerebrovascular event (MACCE) rate of 7.0%, including 3 all-cause deaths (3.0%), 2 strokes (2.0%) and 3 re-revascularizations (3.0%). The HCR-RACAB group had fewer red blood cell transfusion (P=0.030) and intraoperative blood loss (P=0.037) compared with the MV-RACAB group, and there was no statistical difference in the incidence of major perioperative adverse events or MACCE between the two groups during the follow-up period (P>0.05). ConclusionRACAB can be safely applied in the treatment of MV-CAD with good early and mid-term outcomes. High-quality harvesting of LIMA/RIMA and aortic no-touch technique are crucial to achieve these results.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content