west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "桡动脉" 37 results
  • 桡动脉采血后致右手背伸及曲腕功能障碍一例

    Release date:2016-09-07 02:34 Export PDF Favorites Scan
  • Clinical Study on Intervention Treatment Through Radial Arteries on Coranaria Disease

    【摘要】 目的 评估经桡静脉途径介入治疗冠状动脉病变的临床效果及安全性。 方法 将2003年7月-2009年7月接受治疗的174例冠状动脉病变患者随机分为对照组及观察组,对照组采用经典股动脉途径行冠脉介入治疗,观察组采用桡动脉途径介入治疗。观察两组患者穿刺时间、手术时间、穿刺成功率、手术成功率、并发症发生率。 结果 两组穿刺时间、手术时间、手术成功率差异无统计学意义,观察组并发症发生率少于对照组,穿刺成功率低于对照组。 结论 经桡动脉途径介入治疗冠状动脉病变能够减少手术后并发症的发生,临床疗效确切。【Abstract】 Objective To explore the clinical effect of intervention treatment through radial arteries on coranaria disease and its safety. Methods A total of 174 patients with coranaria disease from July 2003 to July 2009 were randomly divided into a control group and an observed group. The patients underwent the intervention treatment through femoral arteries in control group and through radial arteries in observed group. The duration and achievement rate of paracentesis and operation, and the incidence rate of complications were observed and the results in the two groups were compared. Results There were no differences in the duration and achievement rate of paracentesis and operation, and the achievement rate of operation between the control and observed groups. Compared with the control group, the incidence rate of complications and achievement rate of paracentesis were lower in observed group. Conclusion Intervention treatment through radial arteries on coranaria disease could reduce the post-operative complications with reliable therapeutic effect.

    Release date:2016-09-08 09:51 Export PDF Favorites Scan
  • Management and Nursing of Access-site Vascular Complications after Trans-radial Percutaneous Coronary Procedures

    ObjectiveTo discuss the importance of early identification and effective management of puncture-associated complications after trans-radial percutaneous coronary procedures. MethodsA total of 698 patients undergoing trans-radial percutaneous coronary procedures from June to December 2012 were included and followed up. The puncture associated complications and their clinical managements were summarized in the present study. ResultsWe found that trans-radial approach was safe. The main puncture-associated complications included access-site pain, tension blisters and hemorrhagic complication. Complications with severe clinical consequence were rare. Most of the complications could be successfully treated with conservative management including access-site nursing and psychological nursing. ConclusionTrans-radial approach is safe for percutaneous coronary procedures, but close clinical monitoring and nursing are essential.

    Release date: Export PDF Favorites Scan
  • Offpump and Onpump Coronary Artery Bypass Grafting: A Report of 698 Cases

    Objective To summarize the experiences of off-pump coronary artery bypass grafting (off-pump CABG) and on-pump coronary artery bypass grafting (onpump CABG) for patients with coronary artery diseases and to improve the surgical techniques and clinical results. Methods Coronary artery bypass grafting(CABG) were performed from January 2000 to March 2009 on 698 consecutive cases, including 551 male and 147 female with a mean age of 67.2 years(range, 28.0-79.0). There were 552 cases with angina pectoris and 131 with old myocardial infarction. Preoperative cardiac function showed 301 cases in New York Heart Association classⅡ, 339 in class Ⅲ,and 58 in class Ⅳ. Coronary angiography revealed single vessel disease in 21 cases, 2vessel disease in 87, 3vessel disease in 590, and 201 cases had concomitant left main lesions.There were 687 elective CABG and 11 emergency / urgent ones. Offpump CABG were performed on 346 cases and the others received onpump CABG . Results A total number of 2 025 grafts ( range,1-6 grafts, mean, 2.9 grafts /case ) were constructed with 693 left internal mammary arteries,115 free right mammary arteries,229 left radial arteries, and 81 right radial arteries. Total arterial bypass grafting was feasible on 126 cases. Postoperative ventilation duration varied from 0-127 hours (mean, 11.5 hours). Fasttrack procedure was offered to 38 cases with good results.Introaortic balloon pump support were provided to 1 patient preoperatively and 27 postoperatively. There were 25 deaths with a mortality of 3.64% for the elective cases with the cause of acute myocardial infarction ( 5 cases ), low cardiac output syndrome (3 cases),protamine reaction (2 cases),respiratory failure (3 cases), renal failure (2 cases),and multiorgan failure (10 cases).Four deaths occurred to urgent cases with a mortality of 36.36% from low cardiac output syndrome ( 3 cases) and acute myocardial infarction (1 case). One hundred and fiftyone cases(21.63%)developed atrial fibrilation among which 147(97.35%)returned to sinus rhythem with administration of electrolytes and Amiodarone. Resternotomy were performed for bleeding in 12 cases. Upon discharge from the hospital, 511 patients were free from angina while 20 other patients still had coexisting relieved angina. Postoperative followup was carried out on 415 cases(62.03%)for a period of 1month to 8.2 years with 3 deaths for lung cancer (1 case), car accident(1case), and unknown reasons (1 case). Number of patients who were free from angina was 317 and 21 for those who had recurrent angina. The cardiac function improved with 269 cases(65.29%)in New York Heart Association class Ⅱ, 142(34.46%)class Ⅲ, and 1(0.24%) class Ⅳ. Conclusion Good surgical results could be achieved with careful analysis of native Chinese patients’ coronary vessels, individualized operative plan, control of operative risk factors, and proper selection of bypass conduits. Aggressive use of IABP can provide essential support for patients with poor left ventricular function and other high risk factors.

    Release date:2016-08-30 06:06 Export PDF Favorites Scan
  • Application of transradial approach in peripheral interventional therapy

    With the development of interventional therapy technology, trans radial access (TRA) has gradually become the main approach of interventional therapy. Compared with trans femoral access (TFA), TRA has obvious advantages, which can shorten the time of lying in bed and reduce the incidence of complications. However, the radial artery is thinner than the femoral artery, the incidence of spasm is high, and the success rate of puncture is low, so the technical level of operation is required to be high. Nowadays, TRA has been gradually applied to lung cancer, aortic disease, hepatocellular carcinoma, spleen disease, renal artery disease, and other peripheral vascular diseases. With the confirmation of the safety and feasibility of TRA in interventional therapy in different fields, the popularization of TRA in different interventional fields will be supported.

    Release date:2022-06-08 01:57 Export PDF Favorites Scan
  • Effects of Nitroglycerine, Verapamil and Papaverine on Relaxing Function of Human Radial Arteries

    Abstract: Objective To compare the effects of nitroglycerine (NTG), Verapamil(VP), papaverine(PA) and the mixed solution of Verapamil and nitroglycerine (VG) on relaxing function of human radial arteries. Methods The radial arteries of thirty patients were used during the operation of coronary artery bypass grafting (CABG). A short segment (1.0-1.5cm) of radial arteris were taken from the distal end of radial arteries of each patient and were cut into vascular rings, which were mounted in the organ bath chamber and then subject to a series of tests for vascular smooth muscle viability and endothelial integrity. The effects of five storage solutions on the relaxing function were evaluated by “OrganBath” technique. The five solutions included: (1) Ringer’ s solution (control group); (2) VP solution (VP group); (3) NTG solution (NTG group); (4) PA solution (PA group); (5) VG solution (VG group). First, challenged with phenylephrine (10-5mol/L), vasorelaxant effect of these drugs (effect onset and efficacy) was observed at different time point and resting tension was recorded. Second, after 30min preincubation with either verapamil, papaverine, phenoxybenzamine or VG mixture, potassium chloride (final concentration of 60mmol/L) was added in the organ bath chamber and then vasoconstriction was observed subsequently. Finally, after 30min pretreatment of different antispasmodic agent in the same way as described above, the vascular rings were mounted in organ bath chamber and challenged with phenylephrine(10-5mol/L). Vascular spasticity and vosospasm duration were observed at different time point which might provide guidance for optimal timing of clinical application. Results The radial arteries in VG, VP, NTG and PA solutions were relaxed in 11 min after vasospasm and there was no difference between them (Pgt;0.05). But during the initial three minutes,the relaxation effect of VG and NTG was significantly better than other two groups. Relaxation curve showed that the ability of vasodilatation of VG, NTG, VP and PA decreased in order. In the experiment about antivasospasm pretreatment of radial arteries, there was no difference between VG and VP group (Pgt;0.05 ), whose effects were better than NTG and PA group(Plt;0.05 ). After cold storage for 24h, VG and VP still could prevent vasospasm. But NTG and PA hardly had any function and there was no difference compared with the control group (Pgt;0.05 ). Conclusion Although in the final all these drugs could prevent and relieve vasospasm of radial arteries in the different level, it appeared that a combination of verapamil and nitroglycenn is more fit for treating radial artery during CABG operation than other drugs.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
  • 体外循环下冠状动脉旁路移植术中主动脉-桡动脉血压反转一例

    Release date:2018-11-27 04:47 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF REPAIRING WOUND IN WRIST WITH FLAP SUPPORTED BY PERFORATING BRANCH OF FOREARM RADIAL ARTERY AND CATENA-FORM BLOOD VESSEL

    ObjectiveTo explore the clinical application of the flap supported by perforating branch of the radial artery superior wrist catena-form blood vessel in repairing hand and wrist wound. MethodsBetween March 2010 and March 2013, 24 cases of severe wounds in wrist were repaired with the flap supported by perforating branch of forearm radial artery and catena-form blood vessel. There were 15 males and 9 females, aged 19-54 years (mean, 37 years). In 22 patients with trauma, there were 9 cases of machine injury, 5 cases of traffic accident injury, 5 cases of crash injury of heavy objects, 1 case of sharp instrument injury, and 2 cases of electrical injury, with a mean disease duration of 11 days (range, 2-20 days). In 2 patients with tumor excision wound, there were 1 case of right forearm liposarcoma and 1 case of left forearm squamous-cell carcinoma, with the disease duration of 7 days and 3 months, respectively. All cases complicated by bone and tendon exposure. The size of defect was 4.5 cm×4.0 cm to 10.0 cm×7.5 cm, and the size of the flap was 6.0 cm×4.0 cm to 20.0 cm×8.5 cm. The donor site was directly sutured or repaired by skin graft. ResultsPartial flap necrosis occurred in 1 case, and was cured after dressing change; the other flaps survived, and primary healing of incision was obtained. The patients were followed up 6-36 months (mean, 20 months). The flap featured good color and texture, and also recovered protective sensation at 6 months after operation, with a mean two-point discrimination of 12 mm (range, 11-14 mm). No ulcers of the flap was observed. At last follow-up, according to Hand Surgery Society of Chinese Medical Association for functional evaluation of upper limb, the function was rated as excellent in 19 cases, good in 4 cases, and fair in 1 case. ConclusionThe flap supported by perforating branch of forearm radial artery and catena-form blood vessel can be used to repair wound in wrist, which has no injury to the radial artery, and it also could be used for the patients with ulnar and radial artery injuries. Thus it is an ideal method to repair wound in the wrist because the operation is simple, and the flap has good appearance and texture.

    Release date: Export PDF Favorites Scan
  • 前臂桡动脉穿支蒂接力皮瓣修复老年患者腕部创面

    目的总结应用前臂桡动脉穿支蒂接力皮瓣修复老年患者腕部创面的疗效。 方法2013年2月-2014年3月,收治7例老年腕部创面患者。其中男5例,女2例;年龄58~65岁,平均61岁。损伤原因:冲床伤2例,电刨伤3例,机器绞伤2例。创面缺损范围为4.0 cm×3.0 cm~5.0 cm×4.0 cm,采用大小为4.2 cm×3.0 cm~5.0 cm×4.2 cm的桡动脉远端穿支蒂岛状皮瓣修复创面,并以大小为8.0 cm×4.0 cm~12.0 cm×6.0 cm的桡动脉近端穿支蒂皮瓣修复供区。 结果术后皮瓣均顺利成活,切口Ⅰ期愈合。7例均获随访,随访时间8~24个月,平均14个月。皮瓣质地柔软,外观满意,蒂部无臃肿。末次随访时按照Gartland-Werley腕关节功能评分标准评定,获优5例,良2例,优良率100%。 结论前臂桡动脉穿支蒂接力皮瓣修复老年患者腕部创面具有不牺牲主干血管、操作简便的优点,术后疗效满意。

    Release date: Export PDF Favorites Scan
  • CLINICAL APPLICATION OF MICRO TRANSVERSE FLAP PEDICLED WITH SUPERFICIAL PALMAR BRANCH OF RADIAL ARTERY FROM PALMAR WRIST TO REPAIR SKIN DEFECT OF FINGER

    Objective To investigate the clinical application of micro transverse flap pedicled with superficial palmar branch of radial artery from palmar wrist to repair skin defect of finger. Methods Twenty-six cases (26 fingers) with skin defect of finger were repaired with micro transverse flap pedicled with superficial palmar branch of radial artery from palmar wrist between December 2011 and February 2013. There were 20 males and 6 females with the average age of 31.5 years (range, 20-56 years). The causes of injury included cutting injury in 20 cases and crushing injury in 6 cases. The time from injury to admission was 1-5 hours with an average of 2 hours. Injured fingers included thumb in 6 cases, index finger in 6 cases, middle finger in 6 cases, ring finger in 4 cases, and little finger in 4 cases; the locations were the dorsal side of the finger in 6 cases, lateral side in 6 cases, and the volar of the finger tip in 14 cases; there were 4 cases on the proximal phalangeal skin, 8 cases on the middle phalangeal skin, and 14 cases on the distal phalangeal skin. The defect area ranged from 2.0 cm × 1.5 cm to 4.0 cm × 2.0 cm, and the flap area ranged from 2.5 cm × 2.0 cm to 4.5 cm × 2.5 cm. All the donor sites were directly sutured. Results The flaps of 25 cases survived well after operation, and wound healed by first intention; 1 case had partial necrosis and the wound had a scar healing by changing dressing. All cases were followed up 6-12 months (mean, 10 months). The color and appearance of the flaps were satisfactory with tender texture. The two-point discrimination of the flap was 5-8 mm (mean, 6.8 mm). The donor sites healed primarily without scar contracture and limitation of wrist flexion or extension. Conclusion The micro transverse flap pedicled with superficial palmar branch of radial artery from palmar wrist is a good option to repair skin defect of finger. It has the advantages of hidden donor site, the same operative field, great comparability of flap and finger skin, and it can be used as a vascularized tendon or nerve graft.

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content