west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "溶血" 36 results
  • Hemolysis of Xuesaitong Injection

    【摘要】 目的 对市场上流通使用的血塞通注射液在溶血性方面的状况进行考察与研究。 方法 按《中国药典》2005年版一部附录ⅩⅧ B中药注射剂安全性检查法应用指导原则和中药、天然药物刺激性和溶血性研究的技术指导原则,对11 个厂家共计27 批血塞通注射液每批次样品制备4 个浓度,进行溶血实验研究,并采用分光光度法(545 λ/nm)测定计算溶血率,比较各批次样品的溶血率。 结果 不同厂家甚至同一厂家不同批次的血塞通注射液溶血率存在一定差异。 结论 在临床使用中应注意用量,过量使用可能导致溶血引起的不良反应;同时,应注意溶血引起的临床不良反应的观测。【Abstract】 Objective To explore the hemolysis of Xuesaitong injection. Methods According to the Guiding Principles of safety tests on traditional Chinese medicine injection in Annex ⅩⅧ B, Chinese Pharmacopoeia, 2005 Edition 1, and Technical Guidelines of studies on the irritability and hemolytic activity of traditional Chinese medicine and natural medicine, a total of 27 samples of Xuesaitong injections (each sample was diluted into four concentrations) produced by 11 manufacturers had been examined. Spectrophotometry (545 λ/nm) was used to calculate the hemolytic rate. Results There was a certain difference in the hemolytic rate among several samples of Xuesaitong injections produced by different manufacturers, or even different batches by the same manufacturer. Conclusion The dosage of Xuesaitong injections should be noted in clinical use. Excessive use may lead to adverse reactions caused by hemolysis; at the same time, clinical adverse reactions caused by hemolysis should be observed.

    Release date:2016-08-26 02:21 Export PDF Favorites Scan
  • Research progress on hemolysis of rotary blood pump

    Hemolysis is one of the main complications associated with the use of ventricular assist devices. The primary factors influencing hemolysis include the shear stress and exposure time experienced by red blood cells. In addition, factors such as local negative pressure and temperature may also impact hemolysis. The different combinations of hemolysis prediction models and their empirical constants lead to significant variations in prediction results; compared to the power-law model, the OPO model better accounts for the complexity of turbulence. In terms of improving hemolytic performance, research has primarily focused on optimizing blood pump structures, such as adjustments to pump gaps, impellers, and guide vanes. A small number of scholars have studied hemolytic performance through control modes of blood pump speed and the selection of blood-compatible materials. This paper reviews the main factors influencing hemolysis, prediction methods, and improvement strategies for rotary blood pumps, which are currently the most widely used. It also discusses the limitations in current hemolysis research and provides an outlook on future research directions.

    Release date:2025-04-02 10:54 Export PDF Favorites Scan
  • Plasma Exchange for Severe Haemolysis During ReCardiopulmonary Bypass to Patients with Cardiac Surgery

    Abstract: Objective To summarize the clinical experience of plasma exchange (PE) during recardiopulmonary bypass (CPB) of patients with severe haemolysis in cardiac surgery. Methods Between January 2001 and December 2005, five patients required PE for severe haemolysis after cardiac surgery. There were periprosthetic leakage and infective endocarditis in 3 patients, congenital heart disease of pulmonary artery stenosis with unsatisfied right ventricular outflow tract patching in 1 patient and thrombosis during extracorporeal membrane oxygenation (ECMO) in 1 patient. They all need blood purification to avoid acute renal failure. Results Five patients were successfully treated with PE during CPB without major complications. The amount of plasma and blood transfused in the 5 patients were 2.2±0.8L and 0.6±0.3L respectively. The volume of plasma exchange and ultrafiltrate were 3.9±1.8L and 2.4±1.3L respectively.The electrolytes and bloodgas analysis in all patients were maintained at the normal levels. The hemodynamics was stable. After heart resuscitation CPB stopped smoothly. Disappearance of periprosthetic leakage and satisfaction of right ventricular outflow tract patching were observed by echocardiograms after peration.Extubation was performed 24h after the operation in 5 patients, and they were discharged 12 to 53 d after the operation with fully recovery. The urine was clear and the body temperature was normal. Before they left thehospital, the concentration of free hemoglobin was tested in 3 patients. The concentration of free hemoglobin was slightly higher in 1 patient (68mg/L), and normal in 2 patients (lt;40mg/L). Conclusion PE during CPB in severe haemolysis is a safe technique which can effectively prevent acute renal failure caused by severe mechanical haemolysis after cardiac surgery.

    Release date:2016-08-30 06:15 Export PDF Favorites Scan
  • Investigation of Risk and Prognostic Factors for Multidrug-Resistant Acinetobacter Baumannii Infection of Lower Respiratory Tract in Intensive Care Unit of the Second Hospital of Anhui Medical University

    ObjectiveTo investigate the risk factors, prognostic factors and prognosis of Multidrug-Resistant Acinetobacter Baumannii (MDR-AB) infection of lower respiratory tract in Intensive Care Unit (ICU) of the Second Affiliated Hospital of Anhui Medical University. MethodsUsing retrospective analysis, we reviewed and compared clinical data of 77 AB infections in lower respiratory tract cases in ICU from January 2013 to March 2015. According to the resistance, patients were divided into a MDR-AB group and a NMDR-AB group. Then the risk factors, prognostic factors and prognosis of MDR-AB infection were analyzed. ResultsA total of 58 cases in the MDR-AB group, 19 cases in the NMDR-AB group were included. The result showed that, the MDR-AB infection in lower respiratory tract could significantly prolong the length of ICU stay (18.5±16.0 vs. 10.6±9.3 days, P<0.05) and increase the mortality (44.8% vs. 11.1%, P<0.01). Logistic regression analysis showed that the independent risk factors for MDR-AB infection in lower respiratory tract included Acute Physiology and Chronic Health Evaluation Ⅱ (Apache Ⅱ) score >15 (OR=0.138, 95%CI 0.03 to 0.625, P=0.01) and use of carbapenems (OR=0.066, 95%CI 0.012 to 0.0346, P=0.001). The independent prognostic factors included placement of drainage tube (OR=8.743, 95%CI 1.528 to 50.018, P=0.015) and use of vasoactive drugs (OR=12.227, 95%CI 2.817 to 53.074, P=0.001). ConclusionThe MDR-AB infection in lower respiratory tract can significantly prolong the length of ICU stay and increase the mortality. The Apache Ⅱ score >15 and use of carbapenems are the risk factors, and the placement of drainage tube and use of vasoactive drugs can increase the mortality of MDR-AB infection of lower respiratory tract in ICU.

    Release date: Export PDF Favorites Scan
  • 含呋喃唑酮与四环素四联疗法根除幽门螺杆菌致急性溶血性贫血一例

    Release date:2020-03-25 09:12 Export PDF Favorites Scan
  • Effect of autotaxin-lysophosphatidic acid pathway on matrix metalloproteinase-13 in articular cartilage of knee osteoarthritis in rats

    ObjectiveTo investigate the effect of inhibiting autotaxin (ATX)-lysophosphatidic acid (LPA) pathway on the cartilage of knee osteoarthritis in rats.MethodsPrimary chondrocytes within three generations of Sprague-Dawley rats (8 weeks old, male) were randomly divided into 6 groups, including blank control group, model group, 1 μmol/L PF-8380 group, 10 μmol/L PF-8380 group, 1 μmol/L Ki16425 group, and 10 μmol/L Ki16425 group. Except for the blank control group, the other groups were modeled with osteoarthritis using interleukin-1β (10 ng/mL, 24 h), and then the experimental groups, i.e., 1 μmol/L PF-8380 group, 10 μmol/L PF-8380 group, 1 μmol/L Ki16425 group, and 10 μmol/L Ki16425 group, were intervened with 1, 10 μmol/L PF-8380 (ATX inhibitor) and 1, 10 μmol/L Ki16425 (LPA receptor antagonist) for 24 h, respectively. immunocytochemistry staining was used to determine the expression of type Ⅱ collagen (Col Ⅱ) in cytoplasm, and Western Blot was used to determine the expression of ATX, LPA, and matrix metalloproteinase-13 (MMP-13) in chondrocytes.ResultsCompared with the blank control group, the average absorbance of Col Ⅱ in chondrocytes in the model group was significantly reduced (0.003 9±0.000 8 vs. 0.110 0± 0.009 0, P<0.05). The expression levels of ATX, LPA, and MMP-13 in chondrocytes in the model group, 1 μmol/L PF-8380 group, 10 μmol/L PF-8380 group, and 1 μmol/L Ki16425 group were significantly higher than those in the blank control group, while the expression levels of ATX, LPA, and MMP-13 in the 10 μmol/L Ki16425 group had no significant difference with those in the blank control group; the expression levels of ATX, LPA, and MMP-13 in the model group, 10 μmol/L PF-8380 group, and 1 μmol/L PF-8380 group decreased in order; the expression levels of ATX, LPA, and MMP-13 in the model group, 1 μmol/L Ki16425 group, and 10 μmol/L Ki16425 group decreased in order.ConclusionInhibiting ATX-LPA pathway may inhibit the up-regulation of MMP-13 levels in articular cartilage of osteoarthritis in rats to reduce the damage of cartilage.

    Release date:2020-06-25 07:43 Export PDF Favorites Scan
  • ACUTE HEMOLYTIC ANEMIA AFTER LIVER TRANSPLANTATION IN ONE CASE

    【Abstract】 Objective To report 1 case of acute hemolytic anemia after liver transplantation because of ABO compatibility and therapeutic experience. Methods The patient with liver cancer underwent orthotopic piggyback liver transplantation on September 2010 after radiofrequency ablation of the tumors. The donor and recipient ABO blood types were type O and type A, separately. Acute hemolytic anemia occurred at 10 days after transplantation and hemoglobin decreased to 56 g/L. The bone marrow showed active hyperplasia; and myeboid∶erythroid was 0.52∶1. The immunosuppressants were used and type O washed red blood cells were transfused immediately. Results The general condition of the patient was improved; hemoglobin increased gradually and returned to 111 g/L at 34 days after liver transplantation. At 12 months of follow-up, hemoglobin was within normal range. Conclusion Using graft blood type washed red blood cells transfusion and immunosuppressants could be an effective therapeutic procedure in the patient with ABO compatility graft when acute hemolytic anemia occurrs.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • Intravenous Immunoglobulin G for Hemolytic Disease of the Newborn: A Systematic Review

    Objective To assess the effectiveness of intravenous immunoglobulin G (IVIG) in reducing the need for exchange transfusion in neonates with proven haemolytic disease due to Rh and/or ABO incompatibility. To evaluate the effectiveness of IVIG in reducing the duration of phototherapy and hospital stay. Methods We electronically searched CENTRAL, MEDLINE (1966 to May 2008), EMBASE (1992 to May 2008), CBMdisc (November 1979 to May 2008), and also checked the reference lists of all papers identified. According to the Cochrane Handbook for Systematic Reviews of interventions, randomized controlled trials comparing IVIG and phototherapy with phototherapy alone in neonates with Rh and/or ABO incompatibility were identified and analyzed. Results Six RCTs were included. The meta-analysis showed that, IVIG can significantly decrease the requirements of exchange transfusion (RR=0.27, 95%CI 0.18 to 0.42), the duration of hospitalization (WMD= –1.11, 95%CI –1.60 to –0.63) and the duration of phototherapy (WMD= –0.82, 95%CI –1.16 to –0.47). Conclusions Intravenous immunoglobulin (IVIG) is recommended for treating hemolytic disease of the newborn because it is effective in decreasing the requirements of exchange transfusion, the duration of hospitalization and phototherapy. Well designed studies with large sample in multi-center are required for further proving.

    Release date:2016-09-07 11:12 Export PDF Favorites Scan
  • 抗c和抗E抗体引起配血不合一例

    目的 检测对临床输血有意义的不规则抗体,保证输血安全。 方法 检测对临床输血有意义的不规则抗体,保证输血安全。 结果 患者血型为O型,CCDee,血清含抗c、抗E抗体,选择不含c、E抗原的献血者悬浮红细胞交叉配血并输注,无任何不良反应发生。 结论 在输血前血型血清学试验中,抗体筛选对检测抗c、抗E等临床有意义的不规则抗体,对有效避免溶血性输血反应的发生有重要意义。

    Release date:2016-09-08 09:16 Export PDF Favorites Scan
  • 荧光素眼底血管造影后血管内溶血一例

    Release date:2016-09-02 06:03 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content