west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "物体表面" 2 results
  • 三种监测方法评价重症监护病房环境物体表面清洁消毒效果的对比研究

    目的采用3种监测方法评价重症监护病房(ICU)环境物体表面清洁消毒效果,为ICU选择环境物体表面清洁消毒效果监测方法提供依据,提高ICU医务人员对环境清洁消毒工作重要性的认识。 方法2015年4月1日-30日选择ICU手高频接触物体表面100处,分别采用荧光标记监测法、棉拭子采样监测法、平皿印迹监测法监测环境物体表面清洁消毒效果,数据分析采用SPSS 19.0软件处理。 结果荧光标记监测法、棉拭子采样监测法、平皿印迹监测法监测合格率分别为26%、67%和75%,荧光标记监测法合格率低于棉拭子采样监测法和平皿印迹监测法,差异有统计学意义(χ2=33.786,P<0.001;χ2=48.025,P<0.001),棉拭子采样监测法与平皿印迹监测法合格率比较差异无统计学意义(χ2=1.554,P=0.213);3种监测方法结果不合格采样点具有一致性;荧光标记监测法具有便捷性、可视性、操作简单,成本低。 结论荧光标记监测法、棉拭子采样监测法、平皿印迹监测法3种监测方法均可用于评价ICU环境物体表面清洁消毒效果,但荧光标记监测法优于棉拭子采样监测法和平皿印迹监测法。

    Release date: Export PDF Favorites Scan
  • Comparative study among three methods on surface disinfection in Intensive Care Unit

    Objective To compare germicidal effect of three disinfectants acting on frequently-touched surfaces in Intensive Care Unit (ICU) at different time points after disinfection so as to put forward the reasonable disinfection method and interval before the next disinfection. Methods We wiped the four frequently-touched surfaces in ICU with disinfectant containing acidic electrolyzed oxidizing water (EOW) from the building system of hospital, disinfectant wipes, and 500 mg/L chlorine respectively. The culture samples were collected from the surfaces before wiping, and 10 minutes, 30 minutes, 1 hour, 2 hours and 4 hours after wiping respectively. The bacterial clearance rate and the qualified rate of bacterial colony counts on the surfaces were compared among the three different disinfectants at different time points after disinfection. Results The bacterial killing rate of three methods for disinfection of object surfaces decreased with the passing of time. The bacterial killing rate of EOW from the building system of hospital was lower than that of the other two methods at all five time points after disinfection (P< 0.05). The bacterial killing rate at hour four after disinfection using chlorine-containing disinfectant and disinfectant wipes was higher than 90.0%. The qualified rate of bacterial colony counts on the surfaces at 10 and 30 minutes after disinfection among the three groups was not significantly different (P>0.05). The qualified rate of bacterial colony counts on the surfaces disinfected by EOW from the building system of hospital was lower than that in the other two groups at the other three time points (P<0.05), and it was totally unqualified at hour four after disinfection. Conclusions The germicidal effect of EOW from the building system of hospital is inferior to chlorine disinfectant and disinfectant wipes. Moreover, the surface can be easily recontaminated after disinfection. It is suggested that EOW should be used in ICU every other hour. and the other two disinfection methods should be used every two hours.

    Release date:2017-03-27 11:42 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content