west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "瓣周漏" 6 results
  • 右侧开胸小切口清除多次心脏术后感染性心内膜炎赘生物一例

    Release date:2016-08-30 05:46 Export PDF Favorites Scan
  • 白塞氏病合并主动脉瓣置换术后瓣周漏的临床分析

    摘要: 目的 总结白塞氏病所致主动脉瓣置换术后发生瓣周漏的外科治疗经验,探讨相关手术方式和解决方法。 方法 回顾性分析第二军医大学附属长海医院收治的4例白塞氏病所致主动脉瓣置换术后瓣周漏患者的临床资料,均为男性,年龄24~50岁(36±7岁)。其中3例为主动脉瓣重度关闭不全行主动脉瓣置换术后出现瓣周漏行改良Bentall手术,另1例为升主动脉瘤、主动脉瓣重度关闭不全行Wheat术后出现瓣周漏行改良Bentall手术。 结果 4例患者术后恢复顺利,无并发症发生。均痊愈出院。术后随访1~24个月,心功能恢复至Ⅰ~Ⅱ级。3~6个月定期行超声心动图和全主动脉血管造影检查,未发现主动脉瓣周漏复发,人工机械瓣膜功能良好,人工主动脉血管通畅。 结论 白塞氏病合并主动脉瓣或升主动脉病变如单纯行心瓣膜置换术,术后人工瓣膜脱落的发生率较高,改良Bentall手术方式是解决问题的良好方法。

    Release date:2016-08-30 06:03 Export PDF Favorites Scan
  • Reoperation after Mechanical Valve Prosthesis Replacement: An Analysis of 105 Cases

    Abstract: Objective To summarize our operative experiences of cardiac reoperation after mechanical valve prosthesis replacement and investigate the causes of reoperation and the perioperative techniques and operation methods. Methods From January 2001 to December 2008, we performed reoperation on 105 patients (59 males and 46 females, aged 50.2±10.6 years old) who had undergone mechanical valve prosthesis replacement. Among the patients, there were 31 cases of mitral valvular replacement (+ tricuspid valvular plasticity), 38 cases of aortic valvular replacement (+ tricuspid valvular plasticity), 11 cases of Bentall procedure, 7 cases of mitral and aortic bivalvular replacement (+tricuspid valvular plasticity), 8 cases of tricuspid valvular replacement, 6 cases of repairing of prosthetic leakage, and 4 others cases. The time interval between two operations was 3 months to 18 years (46.3 ±31.9 months). Before reoperation, the cardiac function (NYHA) of the patients was class Ⅱ in 27 patients, class Ⅲ in 53 patients, and class Ⅳ in 25 patients. Results There were 6 hospital deaths with a mortality of 5.71%(6/105). All others recovered to NYHA class ⅠⅡ. The causes of mortality included 1 case of multiple organ failure, 1 case of low cardiac output after operation, 1 case of aortic pseudoaneurysm rupture, 1 case of severe infection due to brain complication and 2 cases of prosthetic valve endocarditis (PVE). The causes for cardiac reoperation after mechanical valve prosthesis replacement were 67 cases of prosthetic leakage (63.80%), 16 cases of PVE (15.23%), 14 cases of prosthetic thrombosis (13.33%) and 8 cases of other valvular anomalies. Followup was done for 11 to 107 months, which showed two cases late deaths of cardiac arrest and cerebral hemorrhage. Conclusion Patients who have received mechanical valve prosthesis replacement may undergo cardiac reoperation due to paravalvular prosthetic leakage, paravalvular endocarditis, and prosthetic thrombosis. The keys to a successful cardiac reoperation include appropriate preoperative preparations, operational timing, and suitable choosing of cardiopulmonary bypass and operational skills. 

    Release date:2016-08-30 06:02 Export PDF Favorites Scan
  • Surgical Treatment of Periprosthetic Leakage: Report of 25year Experience with 63 Cases

    Objective To summarize the experiences of surgical treatment for periprosthetic leakage(PPL). Methods A total of 63 patients with PPL (mitral PPL in 34, aortic PPL in 29), age 41±12 years, underwent reoperation with prosthetic valve replacement from Dec. 1980 to Dec. 2005 in this department. Patient characteristics, operative profiles and follow-up data were described and analyzed in detail. Results The perioperative complications occurred in 11 patients (17.5%), five of whom died (the overall hospital mortality: 7.9%). Fifty-five patients were in close follow-up and three of them lost in that period, five patients died in late. Fifty patients long-term survivals were in New York Heart Association class Ⅰ-Ⅱ and follow-up evaluation by echocardiography showed no evidence of recurrence or residual PPL and PPL-related complications. Conclusion More attention should be paid to the study on etiology, pathophysiology, diagnostic methods, and clinical classification of PPL. For patients with PPL, reoperation with prosthetic valve replacement is considerably effective and can obtain an acceptable longterm results.

    Release date:2016-08-30 06:15 Export PDF Favorites Scan
  • A case of perivalvular leakage and attempt of closure operation after transcatheter aortic valve replacement

    This paper reported a 75-year-old female patient. She was admitted to our hospital for “repeated chest pain, shortness of breath for more than 5 years, and syncope 3 times”. The CT scan of the patient showed severe aortic valve stenosis, bicuspid valve, and severe calcification; then she underwent transcatheter aortic valve replacement in our hospital. After the prosthesis was implanted, there was a significant paravalvular leak. Considering the triangular area formed between the calcified clumps, the valve was not fully dilated. Paravalvular leak closure was performed during the operation, attempted through the valve stent mesh to closuring. A rare incarceration of the transmitter occurred. An attempt was made to pull out the incarcerated transmitter through a pull-up technique, which resulted in the prosthesis prolapse. The patient was eventually transferred to surgery aortic valve replacement.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • The 1-year follow-up results of intraprocedural valve-in-valve deployment for treatment of aortic regurgitation following transcatheter aortic valve replacement (TAVR) in a single center

    ObjectiveTo evaluate the efficiency and safety of intraprocedural valve-in-valve deployment for treatment of aortic regurgitation following transcatheter aortic valve replacement (TAVR).MethodsConsecutive patients (n=333) who diagnosed with severe aortic stenosis and underwent TAVR in Zhongshan Hospital affiliated to Fudan University from October 3rd, 2010 to April 21st, 2021 were included. There were 208 males and 125 females aged 76.0±7.0 years. There were 316 patients underwent simple TAVR (simple TAVR group) and 17 patients underwent intraprocedural valve-in-valve deployment following TAVR (valve-in-valve group). Their clinical and echocardiographic outcomes were evaluated and compared.ResultsThere was no significant difference between the two groups of patients at postoperative 30 d and 1 year in all-cause mortality (4.4% vs. 0, P=1.000; 6.3% vs. 0, P=1.000), incidence of pacemaker implantation (10.4% vs. 17.6%, P=1.000; 11.8% vs. 17.6%, P=1.000), incidence of ischemic stroke (1.3% vs. 0, P=1.000; 1.3% vs. 0, P=1.000), mean trans-aortic pressure gradient (11.4±6.4 mm Hg vs. 8.9±4.9 mm Hg, P=0.099; 10.5±7.6 mm Hg vs. 11.2±5.2 mm Hg, P=0.432), left ventricular ejection fraction (62.0%±9.0% vs. 57.0%±12.0%, P=0.189; 63.0%±7.0% vs. 60.0%±8.0%, P=0.170), and incidence of mitral valve dysfunction (0.6% vs. 5.9%, P=1.000; 0.6% vs. 5.9%, P=1.000).ConclusionIt is feasible to treat perivalvular leakage with valve-in-valve technology in the procedure of TAVR, and the short and medium-term effects are satisfied.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content