west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "空心螺钉" 27 results
  • CLINICAL AND RADIOGRAPHIC EVALUATION OF OPEN REDUCTION AND INTERNAL FIXATION WITH HEADLESS COMPRESSION SCREWS IN TREATMENT OF Lisfranc JOINT INJURIES

    Objective To evaluate the clinical and radiographic outcomes of headless compression screws for Lisfranc joint injuries. Methods A retrospective analysis was made on clinical data of 34 patients (36 feet) with Lisfranc joint injuries who underwent open reduction and internal fixation with headless compression screws between January 2006 and January 2012. There were 22 males (24 feet) and 12 females (12 feet), aged 21-73 years (mean, 38.9 years). The causes of injury included traffic accident in 16 cases (17 feet), falling from height in 11 cases (12 feet), crushing in 5 cases (5 feet), and sports in 2 cases (2 feet). Of them, there were 19 cases (20 feet) of closed injury and 15 cases (16 feet) of open injury; there were 7 cases (8 feet) of pure dislocations of tarsometatarsal joints and ligamentous Lisfranc injuries (LD), 22 cases (23 feet) of Lisfranc joint fracture dislocations (LFD), 5 cases (5 feet) of combined Chopart-LFD (CLFD). According to Myerson classification, 5 cases (5 feet) were rated as type A, 7 cases (8 feet) as type B1, 14 cases (15 feet) as type B2, 5 cases (5 feet) as type C1, and 3 cases (3 feet) as type C2. Associated fractures included 12 cases (13 feet) of metatarsal shaft fracture, 4 cases (4 feet) of cuboid fracture, 4 cases (4 feet) of navicular bone fracture, 6 cases (7 feet) of coneiform bone fracture/dislocation, 8 cases (10 feet) of ipsilateral lower limb multiple fracture, and 4 cases (4 feet) of contralateral lower limb multiple fracture. The clinical outcomes were evaluated according to American Orthopaedic Foot and Ankle Society (AOFAS) score and visual analogue scale (VAS) score. Postoperative X-ray films were taken to assess the reduction, internal fixation, and the foot arch height. Results All patients were followed up 1 year to 5 years and 2 months (mean, 3.5 years). X-ray films showed anatomical reduction in 31 cases (33 feet, 91.7%). At last follow-up, AOFAS score and VAS score averaged 80.6 (range, 60-100) and 2.3 (range, 0-6), respectively; the AOFAS score was significantly higher in patients having anatomical reduction than the patients having no anatomical reduction, in patients with LD and LFD than in patients with CLFD, and in patients without cuneiform bone fracture/dislocation than in patients with cuneiform bone fracture/dislocation (P lt; 0.05). There was no significant difference in the talus-first metatarsal angle, the distance between the lateral edge of the base of the first metatarsal bone and the medial edge of the base of the second metatarsal bone, and the arch height between the injured foot and normal foot (P gt; 0.05). Reduction loss was observed in 1 case (1 foot) because of early weight bearing; post-traumatic arthritis developed in 9 patients (10 feet). The incidence of post-traumatic osteoarthritis was higher in the patients with non-anatomic reduction, coneiform bone fracture/dislocation, comminuted intra-articular fractures of Lisfranc joints, the injury types (P lt; 0.05). Conclusion Headless compression screws for fixation of Lisfranc joint injuries can provide satisfactory short- and mid-term clinical and radiographic outcomes. During surgery, the precise anatomic reduction and stable fixation should be paid attention to, especially in patients with CLFD, coneiform bone fracture/dislocation, and comminuted intra-articular fractures of Lisfranc joints so as to control the incidence of the post-traumatic osteoarthritis.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON TREATMENT OF LATERAL FEMORAL CONDYLE FRACTURE WITH POLYLACTIC-CO-GLYCOLIC ACID/HYDROXYAPATITE ABSORBABLE CANNULATED SCREWS IN CANINE

    Objective To evaluate the internal fixation effect, degradation, and biocompatibility of polylactic-co-glycolic acid/hydroxyapatite (PLGA/HA) absorbable cannulated screws in treatment of lateral femoral condyle fracture of canine so as to provide the theory basis for their further improvement and clinical application. Methods Sixteen adult male Beagles (weighing, 9-12 kg) were selected to prepare the models of bilateral lateral femoral condyle fracture; left fracture was fixed with PLGA/HA absorbable cannulated screws as experimental group and right fracture with metal screws as control group. At 2, 4, 8, and 12 weeks after operation, general observation was done and X-ray films were taken for observing fracture healing; bone mineral density was measured; the histological examination was performed; and the degradation property of absorbable cannulated screws was detected. Results All animals survived to the end of the experiment. General observations showed that no fracture displacement occurred and fracture healed at 12 weeks in 2 groups; no breakage, displacement, or loosening of screws was observed in experimental group. X-ray films results showed that the absorbable cannulated screws could not be found out by X-ray in experimental group, but metal screws could be found out in control group; fracture healed with time in 2 groups. The bone mineral density reached the peak at 8 weeks in 2 groups, and no significant difference was found between 2 groups and among different time points in the same group (P gt; 0.05). Histological examination showed that 2 groups had similar fracture healing process at different time points; no obvious inflammatory reaction was found around absorbable cannulated screws in experimental group. The degradation results of absorbable cannulated screws showed that the intrinsic viscosity and molecular weight distribution obviously decreased at 2 weeks; the number average molecular weight and the weight average molecular weight markedly decreased at 4 weeks; and the maximum shear force did not decrease obviously at 8 weeks, and then decreased significantly. Significant differences were found in all indexes among different time points in the same group (P lt; 0.05). Conclusion PLGA/HA absorbable cannulated screws and metal screws show similar fracture healing process for fixing lateral femoral condyle fracture of canine, and the absorbable canulated screws have good biocompatibility. The maximum shear force of PLGA/HA absorbable cannulated screw has no obvious decrease during 8 weeks after operation, so it can ensure full healing of fracture.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • PERCUTANEOUS FIXATION OF PELVIC FRACTURE BY Acutrak FULL THREAD HEADLESS HOLLOW COMPRESSION SCREW

    【Abstract】 Objective To evaluate the effectiveness of percutaneous fixation of pelvic fracture by Acutrak full thread headless hollow compression screw. Methods Between March 2008 and April 2010, 31 patients with pelvic fracture underwent percutaneous fixation surgery with Acutrak full thread headless hollow compression screw (surgical group). The effectivenss was compared with those of 14 patients with pelvic fracture treated conservatively (control group). There was no significant difference in age and sex between 2 groups (P gt; 0.05). The injury was more severe in surgical group than in control group. The standard of short-term recovery was active turning over and walking for 5 steps with walking aids. The standard of long-term recovery was pain, gait, fracture healing, and function recovery. Results In surgical group, the other patients reached the standard of short-term recovery at 1-4 days after injury except 1 patient who had sacral plexus injury; in control group, the patients could turn over at 9-13 days (Tile type A2) and 17-25 days (Tile type B2) respectively, and could walk at 17-21 days (Tile type A2) and at 45-57 days (Tile type B2) respectively. The patients of 2 groups were followed up 6-19 months. The time of fracture healing was 2-6 months. The long-term results were excellent in 29 cases and good in 2 cases in surgical group, and were excellent in 8 cases and good in 6 cases in control group, showing significant difference between 2 groups (χ2=6.636, P=0.017).Conclusion Percutaneous internal fixation combined with Acutrak full thread headless hollow compression screw can provide more effective treatment. It can alleviate patients, pain quickly, improve life quality, and has better long-term effectiveness.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • EFFICACY COMPARISON BETWEEN DYNAMIC HIP SCREW COMBINED WITH ANTI-ROTATION SCREW AND CANNULATED SCREW IN TREATING FEMORAL NECK FRACTURES

    Objective To compare the curative effect of dynamic hi p screw (DHS) combined with anti-rotation screw and cannulated screw in treating patients with Pauwels type II or III femoral neck fracture and to provide the basis for the choice of surgical procedure. Methods Between March 2008 and September 2009, 51 patients with fresh Pauwels type II or III femoral neck fracture were treated with DHS combined with anti-rotation screw (DHS group) and three cannulated screws (cannulated screw group). The DHS group included 23 patients, 13 males and 10 females, aging 27-59 years (mean, 43.2 years); fracture was caused by fall ing in 1 case, by traffic accident in 17, by fall ing from height in 5 with a mean time of 27 hoursfrom injury to hospital ization (range, 12-70 hours); and 23 fractures included 9 Pauwels type II and 14 Pauwels type III femoral neck fracture. The cannulated screw group included 28 patients, 12 males and 16 females, aging 20-60 years (mean, 40.7 years); fracture was caused by fall ing in 1 case, by traffic accident in 22, by fall ing from height in 5 with a mean time of 25 hours from injury to hospital ization (range, 9-38 hours); and 28 fractures included 12 Pauwels type II and 16 Pauwels type III femoral neck fracture. There was no significant difference in the basel ine characteristics between 2 groups (P gt; 0.05). Results The incision heal ing of both groups by first intention was achieved. There were significant differences in operation time, incision size, operation blood loss, the cases of blood transfusion, the amount of blood transfusion, C reaction protein level on the 2nd postoperative day, and hospital ization days between 2 groups (P lt; 0.05). In DHS group, anatomic reduction was observed in 20 cases (86.96%) and satisfactory reduction in 3 cases (13.04%), while in cannulated screw group, anatomic reduction was observed in 25 cases (89.29%) and satisfactory reduction in 3 cases (10.71%) ; there was no significant difference (χ2=0.660, P=1.000). The patients were followed up 12-30 months with an average of 14.8 months. There was no significant difference (P gt; 0.05) in the rate of nonunion (10.71% vs. 0), the implant failure (3.57% vs. 0), and avascular necrosis of the femoral head (10.71% vs. 0) between the DHS group and the cannulated screw group. The union time was (94.5 ± 2.0) days in the DHS group and (106.0 ± 33.5) days in the cannulated screw group, showing no significant difference (t=—1.641, P=0.107). The re-opereation rates and the overall success rates were 25% and 75% in the cannulated group and were 0 and 100% in the DHS group, showing significant differences (χ2=6.650, P=0.012). At last follow-up, there was no significant difference in Harris hip score and visualanalogue scale (VAS) score between DHS group and cannulated screw group (P gt; 0.05). Conclusion The optimal treatment of young adults Pauwels type II or III femoral neck fracture is DHS combined with anti-rotation screw with an high overall success and less compl ications.

    Release date:2016-08-31 05:41 Export PDF Favorites Scan
  • 无头加压空心螺钉治疗舟状骨骨折的早期疗效

    目的 总结无头加压空心螺钉治疗舟状骨骨折的手术方法及疗效。 方法 2009 年12 月-2010 年5 月,采用切开复位无头加压空心螺钉内固定治疗29 例舟状骨骨折患者。男19 例,女10 例;年龄18 ~ 66 岁,平均42 岁。根据Herbert-Fisher 分型:B1 型10 例,B2 型12 例,B3 型5 例,B4 型2 例。受伤至手术时间2 ~ 7 d,平均4 d。 结 果 术后患者切口均Ⅰ期愈合。22 例获随访,随访时间6 ~ 12 个月,平均9 个月。X 线片检查示术后40 ~ 80 d 骨折达骨性愈合,平均60 d。1 例B4 型患者于术后6 个月影像学检查确诊为舟状骨缺血性坏死。末次随访时腕关节功能较术前显著改善。Mayo 腕关节功能评分,获优14 例,良6 例,中2 例。 结论 无头加压空心螺钉加压固定稳定牢靠,是治疗舟状骨骨折的有效方法之一。

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF TWO ARTHROSCOPIC DIFFERENT FIXATIONS FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES

    Objective To compare the effectiveness of arthroscopic screw and suture fixations in treatment of anterior cruciate ligament tibial eminence avulsion fractures. Methods Between January 2002 and January 2009, 43 patients with freshanterior cruciate ligament tibial eminence avulsion fracture were treated, which were rated as types II and III according to Meyers- McKeever-Zaricznyj classification. Fractures were fixed with either screw (screw group, n=21) or nonabsorbable suture (suture group, n=22). There was no significant difference in sex, age, disease duration, and fracture type between 2 groups (P gt; 0.05). The range of motion (ROM) and Lysholm score were compared between 2 groups, and the knee stabil ity was evaluated based on the Lachman test and KT-2000 measurement. Results The operation time was 48-60 minutes (mean, 51.6 minutes) in the screw group, and 55-68 minutes (mean, 63.2 minutes) in the suture group, showing significant difference (t=4.645, P=0.032). Incisions healed by first intention and no compl ication occurred in 2 groups. All patients were followed up (5.7 ± 0.6) years in the screw group and (5.3 ± 0.5) years in the suture group. The fracture healed completely in both groups; the heal ing time was (3.3 ± 0.6) months in the screw group and (3.2 ± 0.4) months in the suture group, showing significant difference (t=3.723, P=0.019). Between the screw group and the suture group, no significant difference was found in ROM [(128.6 ± 10.1)° vs. (130.2 ± 14.1)°, P gt; 0.05] and Lysholm score (94.6 ± 14.5 vs. 95.1 ± 17.2, P gt; 0.05). The stabil ities based on KT-2000 measurement were also similar between 2 groups at last follow-up [(0.9 ± 0.3) mm vs. (1.0 ± 0.4) mm, P gt; 0.05]. Lachman test of 2 groups were negative. Conclusion Boththe screw and nonabsorbable suture fixation techniques for anterior cruciate l igament tibial eminence avulsion fracture (type II or III) have good results in terms of functional outcome and stabil ity. However, some patients show flexion contractures of 5° or 10°.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • TREATMENT OF FEMORAL NECK FRACTURE WITH CANNULATED SCREW FIXATION IN YOUNG ADULTS

    Objective To evaluate the clinical effect of cannulatedscrew on treatment of femoral neck fracture(FNF). Methods Forty-two FNFpatients were treated by using cannulated screw from January 2001 to December 2005.There were 22males and 20 females with an average age of 41 years (19-59 years). Fracture was caused by traffic accident in 21 cases, by falling from height in 14 cases and by bruise in 7 cases. All cases were fresh fracture. According to Garden criterion for typing, 15 cases were classified as type Ⅱ, 16 cases as type Ⅲ and 11 cases as type Ⅳ . It was 7 hours to 15 days from injury to operation. Results Thepatients were followed up for 1-6 years with an average of 2.5 years. The average fracture union time was 6.5 months. Three patients had ischemic necrosis of femoral head, andloosening and breakage of screw and rob was observed in 1 case. According to Brumback criterion for hip joint function, the result was excellent in 18 cases, good in 20 cases and bad in 4 cases, and the excellent and good rate was 90.4%. Conclusion Cannulated screw fixation is a good method to treat FNF in young adults. It can improve the rate of fracture union and reduce the rate of avascular necrosis of femoral head.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • Different Treatments for 29 Cases of Femoral Neck Fracture in Elder People

    目的:总结空心螺钉、DHS或人工关节置换治疗股骨颈骨折的适应证及效果。方法:分别用空心螺钉、DHS固定和人工关节置换3种方法治疗获得随访的中老年股骨颈骨折29例。年龄51~85岁,平均68.3岁。空心螺钉组8例,DHS组15例,人工关节组6例。结果:随访29例,随访时间1~3年,平均2~3年。围手术期无1例死亡,无切口感染,无内固定断裂,无关节脱位。发生退钉2例,股骨头坏死1例。功能评定:优20例,良6例,差3例。结论:根据患者的年龄、经济状况、骨折部位、骨折分型合理地选择治疗方法,是减少并发症,提高治疗效果和老年人生活质量的关键。

    Release date:2016-09-08 10:02 Export PDF Favorites Scan
  • A PRELIMINARY ANATOMICAL STUDY ON DESIGN OF CANNULATED SCREW CHANNELS FOR FIXATION OF SYMPHYSIS PUBIS DIASTASIS IN SMALL SAMPLES

    ObjectiveTo design the channels of parallel screws and cross screws for fixation of symphysis pubis diastasis through a small sample anatomic study on pubic symphysis and its neighbor structures so as to provide anatomical basis for minimally invasive fixation of symphysis pubis diastasis. MethodsEight cadaveric pelvic specimens (6 men and 2 women) were transected along L5 and the proximal 1/3 of bilateral thighs, with intact lumbar spines. The spermatic cord, womb round ligament, and corona mortis were dissected; the distance to the ipsilateral pubic tubercle was measured and subsequently the distance between pubic tubercles, the height of pubic symphysis, the diameter of outer edge of pubic tubercle, the thickness of pubic symphysis and 2 cm outside the pubic symphysis (upper, central, and lower 1/3 thickness of pubic symphysis) were measured to provide anatomical basis for the design of channels of parallel screws and cross screws. ResultsParallel screw fixation: the entry point of first screw was on the outer edge of pubic tubercle, and its exit point was on the outer edge of contralateral pubic tubercle; a cannulated screw with a diameter of 4.5 mm or 6.5 mm can be suitable for this channel. The entry point of second screw was 20 mm outside the pubic symphysis and 23 mm beneath the pubic symphysis, and its exit point was symmetrical with entry point; a cannulated screw with a diameter of 4.5 mm can be appropriate for the second channel. The direction of two screws was perpendicular to the pubic symphysis. Cross screw fixation: the entry point of cross screws was on one side of the pubic tubercle, and its exit point was 20 mm outside the contralateral pubic symphysis and 23 mm beneath the contralateral pubic symphysis; two cannulated screws with a diameter of 4.5 mm can be chosen for cross screws channels. The direction of two cross screws was intersected with the horizontal line of two pubic tubercles at an angle of 25° respectively; besides, two cross screws formed an anteversion angle and retroversion angle of 5-10° with pubic body plane, respectively. ConclusionThe channels of parallel screws and cross screws are feasible for fixation of symphysis pubis diastasis by analyzing the anatomical data of the pubic symphysis and its neighbor structures, but further biomechanical research is need to confirm the stability of two fixation methods.

    Release date: Export PDF Favorites Scan
  • PROGRESS IN TREATMENT OF PUBIC SYMPHYSIS DIASTASIS

    ObjectiveTo summarize the progress in treatment of pubic symphysis diastasis. MethodsRelated literature concerning treatment of pubic symphysis diastasis was extensively reviewed and comprehensively analyzed in terms of anatomy, biomechanics, and treatment. ResultsThere are many fixation methods for treatment of pubic symphysis diastasis, which aims at restoring the stability of the anterior pelvic ring. External fixator is often used as a temporary fixation; tension band wire has been abandoned due to its poor biomechanical stability; screw loosening and plate breakage often appears when a single reconstruction plate is used; box plate significantly increases the biomechanical stability of anterior pelvic ring but it leads to a considerable surgical trauma; locking plate has been used for pubic symphysis diastasis recently, especially for osteoporotic fractures; percutaneous cannulated screw has the advantages of less trauma, less bleeding, and good stability, so it is good choice for treatment of pubic symphysis diastasis. ConclusionThere is no uniform standards about the treatment of pubic symphysis diastasis, but the minimally invasive treatment is an undeniable trend. Percutaneous cannulated screw has achieved satisfactory effectiveness, however, its biomechanical stability and anatomic channels need to be further studied.

    Release date: Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content