  • 尿沉渣中相似有形成分的特征及鉴别

    目的 提高临床检验人员尿沉渣显微镜检中相似有形成分的辨认能力。 方法 通过分析2007年-2012年参加美国病理家协会和卫生部临检中心能力比对试验122份图片标本的回报结果,归纳尿沉渣相似有形成分辨认的主要错误,总结常见的尿沉渣中相似有形成分的形态特征和鉴别要点。 结果 122份样本中115份鉴定结果正确,7份鉴定错误,错误率5.7%。 结论 通过定期的学习和比较,使检验技师尿沉渣相似有形成分的识别能力得到提升,尿沉渣检验质量得到提高。

    Release date:2016-09-07 02:37 Export PDF Favorites Scan
  • Study on senior laboratory technicians training project in West China Hospital of Sichuan University and trainees’ ability assessment after graduation

    With the development of clinical medicine, laboratory personals are required to participate in the analysis and explanation of clinical laboratory tests, and the cultivation of compound senior medical laboratory professionals becomes an urgent clinical need. This article describes the post-graduation education process and content of senior laboratory technicians training in West China Hospital of Sichuan University since 2004, and assesses their comprehensive capabilities of clinical service, teaching and research on the trainees who have graduated for more than 5 years. It is believed that the training mode of senior laboratory technicians could improve the comprehensive quality and personal ability of trainees, make our setting goal come true, and cultivate practical senior laboratory professionals who can fulfill social demands.

    Release date:2021-01-26 04:34 Export PDF Favorites Scan
  • TSK-11G型与B65-01型26号两种骨髓活检针行骨髓活检术的效果比较

    【摘要】 目的 比较日本TSK-11G型骨髓活检针和国产B65-01型26号骨髓活检针进行骨髓活检的效果。 方法 2010年3月-2011年5月门诊行骨髓活检术患者105例,分别用TSK-11G型和B65-01型26号骨髓活检针进行活检,比较所取得骨髓组织的长度达标率和完整性。 结果 TSK-11G型骨髓活检针所取组织质量、长度优于B65-01型26号活检针(Plt;0.05)。TSK-11G型达标92例,占87.62%,取材完整101例,占96.19%;B65-01型26号达标22例,占20.95%,取材完整88例,占83.81%。 结论 TSK-11G型骨髓活检针行骨髓活检术所取骨髓组织更长完整性更好,值得临床推广。

    Release date:2016-08-26 02:18 Export PDF Favorites Scan
  • Application of Sysmex XT-4000i hematology analyzer in cell count and cell differential count of body-fluid samples

    Objective To evaluate the value of Sysmex XT-4000i hematology analyzer in its body-fluid mode in cell count and cell differential count of pleural effusion, ascites and cerebrospinal fluid samples. Methods A total of 95 pleural effusion, ascites and cerebrospinal fluid samples were collected from patients hospitalized between May and September 2015. The samples were tested by Sysmex XT-4000i hematology analyzer (instrument method) and modified Neubauer hemocytometer (manual method) for cell count, and the results of them were compared and analyzed. Results The instrument method and the manual method had a good consistency in nuclear cell count and erythrocyte count (kappa=0.965,P< 0.001; kappa=0.988,P<0.001). There was no significant difference in the count of mononuclear cells (P> 0.05). However, there was a significant difference in the count of multiple nuclear cells (P<0.05). Conclusions Hematology analyzer in its body-fluid mode may replace manual method in cell count of pleural effusion, ascites and cerebrospinal fluids for its high precision, high efficiency and easy operation. However, cell differential count of this method needs microscopic examination assistance.

    Release date:2017-04-19 10:17 Export PDF Favorites Scan
  • Association of MDM2 Gene Promoter SNP 309 Polymorphism with Leukemia Susceptibility: A Meta-Analysis of Case-Control Studies

    Objective To investigate the association between MDM2 gene promoter SNP 309 polymorphism and leukemia susceptibility. Methods Such databases as Ovid, EBSCO, PubMed, CNKI, CBM, VIP and WanFang Data were searched to collect the case-control studies published from January 1990 to June 2012. According to the inclusion and exclusion criteria, the studies were screened, the data were extracted, and the methodological quality of the included studies was evaluated. Then meta-analysis was conducted using RevMan 5.0 and Stata 10.0 software, the pooled odds ratio (ORs) with 95% confidence interval (CI) were calculated, and the sensitivity and publication bias were evaluated at the same time. Results A total of 9 studies within 8 articles were included, which involved 1 821 cases and 5 642 controls. The results of meta-analysis showed that, the susceptibility of leukemia was increased in the G allele carriers compared with the T allele carriers (OR=1.26, 95%CI 1.08 to 1.46, P=0.003), and the leukemia risk was higher in the GG genotype populations compared with the TT genotype populations (OR=1.46, 95%CI 1.02 to 2.10, P=0.04). Among Asians with recessive models, the leukemia risk was higher in the homozygous GG genotype compared with both the heterozygous GT genotype and the homozygous TT genotype (OR=2.00, 95%CI 1.37 to 2.92, P=0.000 3). There was no obvious publication bias. Conclusion MDM2 gene promoter SNP 309 polymorphism is associated with the susceptibility of leukemia, and the G allele is likely to be the risk factor for leukemia.

    Release date: Export PDF Favorites Scan
  • 糖原染色在急性淋巴细胞白血病诊断中的临床意义研究

    目的 分析急性淋巴细胞白血病( ALL) 糖原染色( PAS) 的阳性率,与细胞免疫分型、融合基因分析结果进行比较,探索PAS在ALL诊断中的应用价值。 方法 回顾性分析我院自2010年1月-2012年5月初发ALL患者124例,统计分析其PAS染色、细胞免疫分型、断裂点丛集区基因-abesine鼠白血病基因(BCR-ABL)融合基因、外周血象及相关临床资料。 结果 50 例经细胞免疫分型诊断为早期前B型急性淋巴细胞白血病(Pro-B ALL)的患者,PAS反应阳性者30例(60%);42例经细胞免疫分型诊断为普通型急B性淋巴细胞白血病(Common-B ALL)的患者,PAS反应阳性者23例(55%);32例经细胞免疫分型诊断为急性T淋巴细胞白血(T-ALL)的患者,PAS阳性者12例(37%)。分析显示T-ALL患者PAS的阳性率明显低于Common-B ALL和Pro-B ALL的患者(P< 0.05),Common-B ALL和Pro-B ALL之间PAS阳性率差异无显著的统计学意义(P>0.05)。38 例BCR-ABL融合基因阳性的ALL患者,PAS反应阳性者18例(47%);86例BCR-ABL融合基因阴性的ALL患者,PAS反应阳性者47例(55%),BCR-ABL融合基因阳性和阴性两组比较,PAS阳性率差异无统计学意义(P>0.05)。 结论 PAS 在ALL患者有较高的阳性率,B-ALL中PAS阳性率显著高于T-ALL,PAS可作为一种经济快速的ALL诊断及免疫亚型初步诊断的辅助手段。

    Release date: Export PDF Favorites Scan
  • Research on the Application of UF-1000i Urine Sediment Analyzer in Rapid Urinary Tract Infection Screening by Receiver Operator Characteristic Curve

    ObjectiveTo investigate the feasibility of quantitative detection of WBC count and bacteria count with UF-1000i urinary sediment analyzer in rapid screening for urinary tract infection by receiver operator characteristic (ROC) curve. MethodsFrom August to December 2013, we used quantitative bacterial culture and UF-1000i automatic urine sediment analyzer respectively to examine asepsis urine specimens of 218 patients with suspected urinary tract infection. Among them, there were 95 males and 123 females, with an average age of 54.7 years old. ResultsAmong the 218 urinary samples, 65 were culture positive specimens. With positive urine culture as the gold standard for making ROC curve, the area under ROC curve for WBC count and bacterial numbers by UF-1000i urine sediment analyzer were respectively 0.839 and 0.894. The cut-off values of Youden index for optimal WBC cell count and bacterial count were ≥31.0/μL and 38.8/μL, respectively. When the above numbers were used as cut-off values, the WBC count sensitivity and specificity were 78.3% and 80.4%, the positive likelihood ratio was 3.99, and the negative likelihood ratio was 1.11. And the bacterial count sensitivity and specificity were 84.3% and 80.6%, the positive likelihood ratio was 4.30, and the negative likelihood ratio was 0.80. ConclusionUsing white blood cell count ≥31/μL and bacterial count ≥38.8/μL detected by UF-1000i urine sediment analyzer as the cut off values of noninvasive screening indexes has a very important value in screening for urinary tract infection in the early stage, determining whether there is a need for urine culture, and guiding clinical rational application of antibiotics

    Release date: Export PDF Favorites Scan
  • The Establishment and Application of Quality Control System on Sysmex-XN Series Automatic Blood Cell Analyzer

    ObjectiveTo establish a comprehensive, appropriate quality control system on the Sysmex-XN series automatic blood cell analyzer to improve the reliability of blood cell count results. MethodsRoutine quality control was carried out every day, using high, normal and low levels of fresh whole blood controls offered by Sysmex. The results from the Sysmex online quality control was got timely. We monitored the variation of mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC) with the moving average method real-timely, and quality control was performed for fresh whole blood samples of patients once every two hours. ResultsEverything was under control, and the moving average was within the permitted range. ConclusionThe reliability of laboratory blood cell count results can be effectively improved by using this quality control system effectively and comprehensively on the Sysmex-XN automatic blood cell analyzer.

    Release date: Export PDF Favorites Scan
  • The Performance Evaluation of Sysmex-XN Automatic Hematology Analyzer in Complete Blood Count

    ObjectiveTo evaluate the complete blood count performance quality of Sysmex-XN automatic hematology analyzer. MethodsWe investigated the precision rate, residual contamination rate, analytic linearity range, and background counting of Sysmex-XN-B3 analyzer. ResultsThe inner and inter-group precision test showed that the inaccuracy of the analyzer was lower than the allowable standard of 1/4 (CLIA'88). The highest level of residual contamination rate was 0.12%, lower than the standard of manufacturer (≤1%). Linearity evaluation showed that the white blood cell count analytic linear range was from 0.51×109/L to 393.40×109/L, the red blood cell count analytic linear range was from 0.51×1012/L to 8.15×1012/L, the hemoglobin analytic linear range from 15.0 g/L to 244.5 g/L, and the platelet count analytic linear range was from 3.0×109/L to 2 072.5×109/L. Background counting was also lower than the standard of manufacturer. Comparison between the two different series of analyzers showed that the inaccuracy rate of Sysmex-XN-B3 was not only lower than the standard of National Center for Clinical Laboratories, but also lower than the standard of 1/2 (CLIA'88). ConclusionSysmex-XN automatic hematology analyzer has a high performance in capability evaluation. It is an excellent tool for routine hematologic blood examination.

    Release date: Export PDF Favorites Scan
  • Comparison of diagnostic significance between myeloperoxidase staining and cytoplasm myeloperoxidase in acute leukemia cells

    Objective To detect the difference between the peroxidase (POX) by cytochemical staining and cytoplasm myeloperoxidase (cMPO) by flow cytometry in acute leukemia cells, and provide a more accurate basis for the classification of leukemia. Methods The positive rate of POX in acute leukemia cells was detected by cytochemical staining. The positive rate of cMPO in acute leukemia cells was detected by flow cytometry. Then the positive rate of POX and cMPO, and the positive cells score were analyzed. Results The positive rate and the positive cells scores between POX and cMPO in acute lymphoblastic leukemia were significantly different (P<0.05), the positive rate and the positive cells scores of POX were significantly higher than those of cMPO. The positive rate between POX and cMPO in acute non-lymphoblastic leukemia (ANLL) had significant differences (P<0.05), the positive rate of cMPO was higher than that of POX; but no difference was found between POX and cMPO positive cells scores in ANLL (P>0.05). In acute myelocytic leukemia (AML)-M1 subtype, significant difference was found in the positive rate between POX and cMPO (P=0.006); cMPO positive rate was significantly higher than that of POX, but the POX positive cells score was significantly higher than that of cMPO (P=0.001). There were no significances of positive rate and positive cells score in AML-M2, AML-M3, AML-M4, AML-M5 subtypes between POX and cMPO (P>0.05). Conclusions There are not major differences between positive rate of POX and cMPO, as well as the positive cells scores in acute leukemia, especially acute myelocytic leukemia. We can choose the better method according to the actual situation and the sensitivity requirements. The two methods should be replenished by each other and used alternately.

    Release date:2017-07-21 03:43 Export PDF Favorites Scan