west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "纳米碳" 8 results
  • RESEARCH PROGRESS OF NEURAL TISSUE ENGINEERING BASED ON ELECTRICALLY CONDUCTIVE CARBON NANOTUBE SCAFFOLD

    Objective To review the basic researches and the cl inical appl ication of the nano-neural tissue engineering materials, especially the electrically conductive carbon nanotubes (CNT). Methods The l iterature concerning the basic and cl inical researches of the conductive materials of nano-neural tissue engineering, especially the electrically conductive CNT were reviewed. Results The researches of conductive materials of nano-neural tissue engineering have made some progress, the electrically conductive CNT can not only promote Schwan cells’ adhension, migration, and prol iferation, but also mimic the function of electric conductivity of neural myel in and enhance neurite growth and regeneration. So the electrically conductive CNT make great sense in stimulating and directing the growth of neurite and the regeneration of axons. Conclusion Because of these unique properties, the electrically conductive CNT have great advantages in peripheral nerve repair and function reconstruction, and are promising to provide a novel method for cl inical peri pheral nerve repair and function reconstruction after injury.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • The Applied Significance of Carbon Nanoparticles in Central Compartment Lymph Node Dissection in Treatment of cN0 Papillary Thyroid Carcinoma

    Objective To assess the applied significance of carbon nanoparticles in central compartment lymph node dissection in treatment of cN0 papillary thyroid carcinoma. Methods Sixty-eight patients with cN0 papillary thyroid carcinoma who were treated in Tongji Hospital of Tongji Medical College from May. to Oct. in 2012 were randomly allocated to the control group (n=32) and the carbon nanoparticles trace group (tracer group, n=36), receiving non-carbon nanoparticles trace and carbon nanoparticles trace respectively. All patients were received total resection of thyroid plus the affected side and (or) contralateral side central compartment lymph node dissection. The lymph node-related indexes(including number of dissected lymph node at Ⅵarea and lymph node metastasis rate at Ⅵarea) and operative indexs (including operation time, blood loss, drainage time, complication, and hospital stay) were collected and compared between the 2 groups. Results There were 205 and 324 dissected lymph node at central compartment in control group and tracer group respectively. The results of postoperative pathology showed that the number of lymph node in central compartment of the tracer group was much more than those of control group (8.99±2.24 vs. 6.41±1.56, P<0.001). The metastasis rate of central compartment lymph node were 40.6% (13/32) in control group and 47.2% (17/36) in tracer group, but there was no significant difference between the 2 groups (P=0.762). But in medial area of laryngeal recurrent nerve, the metastasis rate in the tracer group (38.9%, 14/36) was much higher than those of control group (12.5%, 4/32), P=0.029. There were no significant differences in the operation time, blood loss, drainage time, hospital stay, and complication incidence such as bleeding, temporary hypocalcemia, and injury of superior laryngeal nerve between 2 groups (P>0.05). All the patients in 2 groups had followed-up for 6 months without death, recurrence, and metastasis.Conclusions The lymphatic tracer technique of carbon nanoparticles may improve the number of dissected lymph nodes in central region of cN0 papillary thyroid carcinoma, without increasing (or prolonging) operation time, intraoperative blood loss, and postoperative hospital stay, and can accurately represent the metastasis of lymph node, thus to make the staging of the tumor accurately and guide postoperative treatment.

    Release date:2016-09-08 10:35 Export PDF Favorites Scan
  • Application of Lymphatic Mapping to Recognize and Protect Negative Stained Parathyroid in Thyroid Carcinoma Surgery by Using Carbon Nanoparticles

    Release date:2016-09-08 10:35 Export PDF Favorites Scan
  • 纳米碳混悬液在食管癌根治术中的应用

    目的探讨钠米碳混悬液在食管癌根治术中淋巴示踪的应用效果。 方法2012年7月-2013年5月诊治的80例食管癌患者随机分为纳米碳组和对照组各40例,前者于术中先向癌灶周围注入钠米碳后再行根治术,后者则不应用纳米碳直接行食管癌根治术。记录黑染淋巴结与未黑染淋巴结数量以及淋巴结转移情况。 结果钠米碳组平均每例清除(17.9±5.8)枚淋巴结,淋巴结黑染率为51.7%;对照组平均每例清除(14.1±5.3)枚淋巴结,纳米碳组淋巴结清除数明显高于对照组(t=3.041,P=0.003)。纳米碳组黑染淋巴结转移率13.0%,对照组淋巴结转移率7.3%,纳米碳组黑染淋巴结转移率明显高于对照组(χ2=8.379,P=0.004),同时纳米碳组微小转移淋巴结清除率高于对照组(χ2=4.047,P=0.044)。两组术后并发症发生率差异无统计学意义(P>0.05)。 结论钠米碳混悬液淋巴结示踪效果良好,操作简便,能指导医师制定淋巴结清扫方案,为术后提供更加准确的病理分期。

    Release date: Export PDF Favorites Scan
  • Application Advances of Carbon Nanoparticles in Thyroid Carcinoma Surgery

    ObjectiveTo explore the value of carbon nanoparticles on surgery for thyroid carcinoma. MethodLiteratures about application of carbon nanoparticles and lymphatic mapping in the thyroid carcinoma were reviewed. ResultsThe carbon nanoparticle was a new lymph tracer with a clear lymphatic mapping and a longer time for dying, which could accurately reflect the status of cervical lymph nodes, trace the sentinel lymph node in the thyroid carcinoma. The parathyroid gland could not be stained black, it was easy to be identified and protected. ConclusionsThe carbon nanoparticle provides an effective help in treatment for thyroid carcinoma. The more extensive and more profound application of lymphatic mapping depends on more clinical study.

    Release date: Export PDF Favorites Scan
  • Precise Dissection of Lymph Node Guided by Carbon Nanoparticles in Reoperation for Thyroid Cancer Recurrence

    ObjectiveTo investigate the value of carbon nanoparticle adopted in reoperation for thyroid cancer recurrence. MethodsFrom July to November of 2015, patients diagnosed with thyroid cancer recurrence in department of Thyroid & Parathyroid surgery, West China Hospital, Sichuan University were enrolled in the research. All enrollment patients underwent carbon nanoparticles location guided by ultrasonography before reoperation. Relative data about surgery and location were analyzed retrospectively. ResultsTwenty-two patients were enrolled in the research. Mean operation time was (60.45±12.91) minutes. During surgery, a total of 405 (average 18.4) lymph nodes were harvested, and the staining rate was 71.9% (291/405). The pathological examination showed that there was a significant difference in the positive rate between carbon nanoparticles stained lymph nodes (45.0%, 131/291) and non-stained lymph nodes (5.3%, 6/114), P < 0.001. In addition, the positive rate in non-targeted stained lymph nodes was 30.2% (62/205). By contrast, it was 5.3% (6/114) in non-targeted non-stained lymph nodes. The difference showed significant significance (P < 0.001). ConclusionsAdoption of carbon nanoparticles in reoperation for thyroid cancer, which improves efficiency of dissection for the non-palpable lymph nodes metastasis, is worth generalizing in clinical practice.

    Release date:2016-10-25 06:10 Export PDF Favorites Scan
  • Application of Subserosal Injection of Carbon Nanoparticle Lymphatic Tracer in Laparo-scopic Assisted Radical Gastrectomy for Advanced Gastric Cancer

    ObjectiveTo investigate the applicated value of carbon nanoparticle lymphatic tracer in laparoscopic assisted radical gastrectomy for advanced gastric cancer. MethodsForty-two patients with advanced gastric cancer who were admitted to the Department of General Surgery in The Affiliated Cancer Hospital of Zhengzhou University from March to September in 2014, were collected prospectively and randomly divided into two groups (carbon nanoparticle group and control group), each group enrolled in 21 cases. After improving relevant auxiliary inspection, subserosal injection of carbon nanoparticle around the tumor was performed via venous infusion needle laparoscopically at the beginning of surgery in carbon nanoparticle group, while the patients routinely underwent laparoscopic assisted radical gastrectomy in control group. Comparison of the results of harvested lymph nodes and its detection time between the two groups was performed, and the perioperative complications were also evaluated. ResultsA total of 678 lymph nodes were detected in carbon nanoparticle group and 447 lymph nodes were detected in control group. The number of harvested lymph nodes in carbon nanoparticle group (32.28±4.10) was significantly higher than that of control group (21.28±2.74), P < 0.05. The mean harvest time in carbon nanoparticle group was shorter than that of control group[(24.09± 3.58) min vs. (32.76±4.76) min, P < 0.05]. The proportion of harvested small lymph node (≤5 mm) in carbon nanoparticle group was higher than that of control group[71.68% (486/678) vs. 48.99% (219/447), P < 0.01]. The number of black-dyed harvested lymph node was 506 (74.63%) and the metastasis rate of black-dyed lymph node was 26.28% (133/506) in carbon nanoparticle group, that the metastasis rate of black-dyed lymph node group was significantly higher than those of without black-dyed lymph node group[6.40% (11/172)] and control group[19.24% (86/447)], P < 0.05. No serious side effect caused by carbon nanoparticle was observed. ConclusionsThe application of diluted carbon nanoparticle lymphatic tracer has a good effect in the dissection of lymph nodes in laparoscopic assisted radical gastrectomy for advanced gastric cancer. It improves the detection rate of lymph nodes, especially the small lymph nodes, and it is safe and feasible.

    Release date:2016-12-21 03:35 Export PDF Favorites Scan
  • Meta-analysis of the effect of nanocarbon in lymph node dissection of gastric cancer

    ObjectiveTo explore the clinical applicability and safety of nanocarbon in patients with gastric cancer, and evaluate its application value in radical gastrectomy.MethodsCollectted relevant literatures on radical gastrectomy for nanocarbon scales from the time of construction of the library to February 2019, according to search databases included PubMed, Embase, Cochrane Library, China Journal Full-text Database (CNKI), and Wanfang. The data of lymph node detection, detection time, number of lymph node metastases, and postoperative complications were extracted from the two groups. We systematically evaluated it, and analyzed the two groups by using RevMan 5.3 software.ResultsWe searched 88 articles and selected 10 articles, including 5 randomized controlled trials and 5 case-control studies. There were 784 patients in the nanocarbon group and 695 patients in the non-nanocarbon group. Results of meta analysis on the clinical utility and safety of nanocarbon labeled lymph nodes showed that, the number of lymph node detection, lymph node detection time, and number of lymph node metastases in the nanocarbon group and non-nanocarbon group were statistically significant (P<0.05), they were better in the nanocarbon group. There was no significant difference in postoperative complications between the two groups (P>0.05).ConclusionsNanocarbon has a clear trace effect on lymph nodes of gastric cancer. It can reduce the difficulty of the number of lymph node detection, improve the detection rate of lymph nodes, and avoid blindness during traditional lymph node dissection.

    Release date:2019-09-26 10:54 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content