west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "缺损" 1098 results
  • 腓肠浅动脉逆行岛状皮瓣修复跟腱及足跟软组织缺损

    Release date: Export PDF Favorites Scan
  • Analysis of Failure of Perventricular Device Closure of Ventricular Septal Defect

    摘要:目的:分析微创外科室间隔缺损(ventricular septal defect,VSD)封堵失败原因,以期提高术前超声心动图筛查水平。方法:回顾性分析25例微创外科VSD封堵失败改行修补术病例,对比超声表现及手术所见,归纳总结产生并发症的原因。结果:残余分流与VSD假性膜部瘤右室面具有多个出口和低估VSD大小密切相关;VSD合并主动脉瓣右冠瓣脱垂是主动脉瓣反流的主要原因;封堵器移位与低估VSD大小且使用偏心封堵器有关;原有三尖瓣反流加重和发生Ⅲ度房室传导阻滞VSD均位于隔瓣下方;封堵失败组较封堵成功组缺损偏大,差异具有统计学意义(Plt;0.05)。结论:超声心动图对VSD及其毗邻结构的细致评估,有助于严格适应证,提高手术成功率。 Abstract: Objective:To analyze the failure of perventricular closure of ventricular septal defect (VSD), in order to improve the preoperative echocardiography examination. Methods: Twentyfive cases underwent surgical repair after failure of perventricular closure of VSD were included in this study. With combination of echocardiographic and surgical findings, retrospective analysis of the failure of perventricular closure of VSD were attempted to summarize the cause of complications.Results: Residual ventricular communication was due to underestimation of size of VSD and pseudomembranous aneurysm resulting in multiple outlets of VSD on the right ventricle side; preoperative prolapse of rightcoronary cusp was the main reason for mild or greater than mild aortic valve regurgitation after eccentric device closure of VSD; Underestimation of the size of VSD and using eccentric occluder device were responsible for the displacement of VSD occluder device. Postoperative aggravated tricuspid regurgitation and Ⅲ°atrialventricular block (AVB) were attributed to VSDs located under the septal leaflet of tricuspid valve. The size of VSD in group of failed perventricular device closure of VSD was larger than that in group of successful device closure of VSD,and the difference was significant(Plt;0.05). Conclusion: Echocardiography vividly reveals VSD and adjacent structures, which should be used in accessing the anomaly and defect and formulating surgical plans to reduce surgical morbidity and mortality.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • APPLICATION OF PEDICLED ANTEROLATERAL THIGH FLAP TRANSFERRING FOR COVERAGE OF OVERSIZED SKIN DEFECT OF HAND

    Objective To introduce the application of the pedicled anterolateral thigh flap transferring for coverage of the oversized skin defect of the hand. Methods The pedicled anterolateral thigh flap was transferred to cover the large skin defects of the hands or the skin defects of theabdomen after the abdominal flap transferred to the hand in 5 male patients aged 16-44 years from April 2002 to August 2005. The injured sites were as follows:4 right hands and 1 left hand, including 2 hands injured by a machine and 3 hands injured by burning.The mechanically injured patients underwent an operation within 6 hours after the injury. The burned patients were reconstructed by the flap transferring 4-7 days after the burn when the decayed tissues could be clearly indentified.The areas of the hand defects were 12.19 cm×18.22 cm.The areas of the pedicled anterolateral thigh flaps were 7.12 cm×16.24 cm. The areas of the abdominal flaps were 13.20 cm×19.23 cm.The pedicles were separated 3 weeks after the repairing operation. Results All the flaps survived well and there was no vascular crisis, with the wound healing of the first intention. The skin defects of the hand were covered completely. Five patients were followed up for 6-12 months. The texture of the flaps was soft and the flaps had a good blood circulation. Of the patients, 3 underwent the finger exclusion and degreasing operation 47 months after operation. All the flaps of the hands had protective sensation, which could meet the requirement of the daily life. Conclusion The pedicled anterolateral thigh flap can provide the large coverage for the skin defects of the hands. The risk of the operation can be greatly decreased by obviation of the vessel anastomosis. It can be an optimal choice for themanagement of the oversized skin defects of the hands.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • 带蒂食指背侧皮瓣鼻再造

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • 皮肤扩张法修复头皮缺损伴颅骨外露15例

    Release date:2016-09-01 09:33 Export PDF Favorites Scan
  • THE EFFECT OF FIBULA FLAP GRAFT ON THE RESTORATION OF THE EXTREMITIESWITH TRAUMATIC COMPOUND TISSUE DEFECTS

    Objective To evaluate the clinical effects of fibula flap grafts on the repair of the extremities with traumatic compound tissue defects. Methods In 12 cases, the fibula flap grafts were employed to restore the extremities with traumatic compound tissue defects. Of the 12 patients, 9 were males, 3 were females; their ages ranged from 12 to 45. There were 2 cases of tibia defect combined with fibula fracture, 2 cases of tibia defect, 2 cases of radius defect, 3 cases of ulna defect, 1 case of calcaneus defect,and 2 cases of firstmetatarsus defect. The bone defect length ranged from 4.2 to 10.6 cm, 7.8 cm in average.The skin defect area ranged from 10.0 cm×4.5 cm to 27.0 cm×15.0 cm. The free transplantation of fibular flaps were used in 9 cases, the lapse operation were used in 2 cases, retrograde shift were used in 1 case. Results Postoperational vein crisis and commonperoneal nerve traction injury were observed in category mentioned above respectively. All the 12 fibula flaps survived after proper treatments such as removalof great saphenous vein. Follow-ups were done for 6 to 24 months. Both the transferred fibula and the recipient broken end reflected bones were healed. Four patients underwent the second-phase reconstruction operation oftendon moving power. One wrist and 1 ankle underwent arthrodesis in 3 to 6 months.All the effects were satisfactory. Conclusion The fibula flap grafts provide arelatively better alternative to repair the extremities with long bone compoundtissue defects. In addition, the sensory function reconstruction of fibula flaps should be given full attention.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • NARROW PEDICLED INTERCOSTAL CUTANEOUS PERFORATOR THIN FLAP FOR COVERAGE OF SKIN DEFECT OF HAND

    Abstract The narrow pedicled intercostal cutaneous perforater (np-ICP) thin flaps were successfully used for reconstruction of hand deformity from scar contraction. This flap was designed with a narrow pedicle (3~5cm in width) which included ICPs of 4th~9th intercostal spaces, and with awide distal part (the maximum is 15cm×15cm) which covered the lower chest and upper abdomen. The thickness of flap was cut until the subdermal vascular networkwas observed. The pedicle was divided between the 7th~14th days after operation. Sixteen flaps in 15 cases were transferred for covering of the skin defects at the dorsum of the hand. The perforators which were included in the narrow pediclewere mostly from the 7th intercostal spaces in 9 flaps. Fifteen of the 16 flapswere survived almost completely, except in one case there was necrosis of the distal portion of the flap. It seemed that this flap was more useful than the conventional methods, not only functionally but also aesthetically. Moreover, the operative techinque was more simple and safer than the island or free intercostalflap due to without the necessity to dissect the main trunk of the intercostalneurovascular bundle. Gentle pressure on the thinning portion of the flap for a short time after operation was important.

    Release date:2016-09-01 11:10 Export PDF Favorites Scan
  • 腓肠肌筋膜蒂皮瓣移位修复胫前皮肤缺损

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • ABSTRACTS PRIMARY REPAIR OF 65 CASES OF HAND DEFECT BY PEDICLED GROIN FLAP

    From jan.1984 through dec.1991,65 cases of hand skin defects were primarily repaired by podicled groin flap. Four of the 65 cases had skin defects on both sides of the palms and dorsal aspot of the hands which were treated by the Y-shaped hypogastric groin flap .Five easec had thumb loss in which the lxdicled groin tubed flap was used to reconstruct the thumb.The time of division of the pedicles ranged from 14 to 28 days(averaged 16 days).All flape survived after division of the podicl...

    Release date:2016-09-01 11:18 Export PDF Favorites Scan
  • 硅胶带修复四肢皮肤软组织缺损16例

    Release date:2016-09-01 09:30 Export PDF Favorites Scan
110 pages Previous 1 2 3 ... 110 Next

Format

Content