Objective To evaluate the effectiveness of locking plates for Neer 3- and 4-part proximal humerus fractures. Methods A retrospective analysis was made on the clinical data of 77 patients with 3- or 4-part proximal humerus fractures, who underwent open reduction and internal fixation of locking plates and were followed up more than 12 months between July 2008 and May 2011. There were 39 males and 38 females with an average age of 54.2 years (range, 18-81 years). Fractures were caused by falling in 47 cases, by traffic accident in 16 cases, by falling from height in 4 cases, by sporting in 5 cases, and by other reasons in 5 cases. The time between injury and operation was 2-16 days (mean, 4.5 days). According to Neer classification, there were 54 cases of 3-part fracture and 23 cases of 4-part fracture. The Constant scores, visual analogue score (VAS), and the complications were evaluated during follow-up. Results After operation, healing of incisions by first intention was obtained in 76 cases and healing by second intention in 1 case. All patients were followed up 12-36 months (mean, 18.5 months). At last follow-up, the Constant score was 71.1 ± 11.9; the results were excellent in 18 cases, good in 24 cases, fair in 25 cases, and poor in 10 cases with an excellent and good rate of 54.5%. The VAS score was 2.8 ± 2.2. Bone nonunion occurred in 2 cases; the other patients had bone union within 2-6 months (mean, 3.2 months). The complications occurred in 25 cases (32.5%). Revision surgery was performed in 15 patients (19.5%). Conclusion The treatment of Neer 3- and 4-part proximal humerus fractures remains challenging. Anatomic reduction, stable fixation, and reduced humeral head blood supply disruption may lead to a satisfactory outcome.
Objective To review the biomechanics of internal fixators for proximal humeral fractures, and to compare the mechanical stabil ity of various internal fixators. Methods The l iterature concerning the biomechanics of internal fixators for proximal humeral fractures was extensively analyzed. Results The most important things for best shoulder functional results are optimal anatomical reduction and stable fixation. At present, there are a lot of methods to treat proximal humeral fractures. Locking-plate exhibites significant mechanical stabil ity and has many advantages over other internal fixators by biomechanical comparison. Conclusion Locking-plate has better fixation stabil ity than other internal fixators and is the first choice to treat proximal humeral fractures.
ObjectiveTo observe the influence of different humeral neck-shaft angle on the efficacy in the treatment of proximal humeral fractures with locking plate. MethodsA total of 106 patients with proximal humeral fractures were treated by locking plate between March 2009 and March 2013, and the clinical data were retrospectively analyzed. Of 106 cases, 58 were male and 48 were female, aged from 26 to 71 years (mean, 52.3 years). The causes were traffic accident injury in 54 cases, falling injury from height in 23 cases, falling injury in 21 cases, and others in 8 cases. According to the Neer classification, there were 32 cases of two-part fractures, 65 cases of three-part fractures, and 9 cases of four-part fractures. The time from injury to operation was 1-7 days (mean, 2.7 days). According to neck-shaft angle by X-ray measurements at 1-3 days after operation, the patients were divided into 3 groups:valgus group (>145°), normal group (126-145°), and varus group (<126°) to observe the influence of neck-shaft angle on efficacy. ResultsAccording to postoperative humeral neck-shaft angle, there were 10 cases in valgus group, 75 cases in normal group, and 21 cases in varus group. There was no significant difference in general clinical data among 3 groups (P>0.05). The patients were followed up 6-12 months. The X-ray results showed fracture healing, and no significant difference was found in fracture healing time among 3 groups (P>0.05). After 6 months, the varus angle of femoral head and visual analogue scale (VAS) score of normal group were significantly lower than those of valgus group and varus group (P<0.05). The excellent and good rate of Constant-Murley score was 78.67% (59/75) in normal group, and it was significantly higher than that in valgus group (60.00%, 6/10) and varus group (42.86%, 9/21) (P<0.05), but there was no significant difference between valgus group and varus group (P>0.05). The complication rate was 28.57% (6/21) in varus group, was 10.67% (8/75) in normal group, and was 20.00% (2/10) in valgus group, showing no significant difference among 3 groups (χ2=4.31, P=0.12). ConclusionReconstruction of normal neck-shaft angle is the key to good shoulder function and clinical efficacy in the treatment of proximal humeral fracture.
Objective To investigate the effectiveness of proximal humerus internal locking system (PHILOS) plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture. MethodsThe clinical data of 48 patients with proximal humeral fractures admitted between January 2016 and December 2020 were retrospectively analyzed, including 18 males and 30 females. The age ranged from 28 to 69 years (mean, 56.3 years). The causes of injury included falling in 39 cases and traffic accident in 9 cases. The time from injury to operation was 2-5 days (mean, 2.8 days). All of them were Neer type Ⅳ proximal humerus fractures, including 11 patients with dislocation. All patients underwent internal fixation with a PHILOS plate after anatomical reduction of the greater nodule, and the rotator cuff was sutured to the plate to reinforce fixation. The operation time was recorded, the wound healing, fracture healing, and complications were observed. The visual analogue scale (VAS) score, Constant-Murley shoulder score, University of California Los Angeles (UCLA) score, and American Shoulder and Elbow Surgeons (ASES) score were used to evaluate shoulder function before operation, at 3 months after operation, and at last follow-up. Results The operation time ranged from 65 to 90 minutes (mean, 76.9 minutes). All incisions healed by first intention. All patients were followed up 9-16 months (mean, 12 months). Fracture reduction was good and all fractures healed, the healing time was 2-6 months (mean, 4.6 months). There was no complication such as subacromial impingement, fracture redisplacement, and screw removal during follow-up. One patient had humeral head necrosis, but the basic function of the shoulder joint was acceptable, the symptoms were mild, and no treatment was performed. At 3 months after operation, the upper limb function of the patients basically recovered. The VAS score, Constant-Murley score, UCLA score, and ASES score significantly improved at 3 months after operation and at last follow-up when compared with preoperative, and further improved at last follow-up than at 3 months after operation (P<0.05). ConclusionPHILOS plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture has the advantages of promoting early postoperative rehabilitation exercise, improving postoperative function of shoulder joint, and reducing complications.
ObjectiveTo review the research progress in the treatment of proximal humeral fractures with fibular allograft and locking plate.MethodsThe literature about the treatment of proximal humeral fractures with fibular allograft and locking plate was reviewed and analyzed from the aspects such as the biomechanics, imaging prognosis, and clinical prognosis.ResultsFibular allograft and locking plate can provide effective medial support for proximal humeral fracture and increase the strength of internal fixation system. Compared with locking plate, fibular allograft combined with locking plate can maintain better humeral neck-shaft angle and the humeral head height after operation in the treatment of proximal humeral fractures, and has better shoulder mobility and shoulder joint function, and does not increase the risk of complications.ConclusionFibular allograft combined with locking plate may be a new and effective treatment for proximal humeral fractures. However, the long-term follow-up results are insufficient, the final outcome of fibula is uncertain, and the long-term potential adverse reactions caused by this treatment are still indefinite.
ObjectiveTo analyze the effectiveness of proximal humeral internal locking system (Philos) plate for proximal humerus fracture. MethodsThirty-three patients with proximal humerus fracture were treated with open reduction and internal fixation with Philos plate between January 2009 and January 2014. There were 19 males and 14 females, aged 23-89 years (mean, 56.6 years). The left side was involved in 15 cases, and the right side in 18 cases. The injury causes included falling in 20 cases and traffic accident in 13 cases. All cases received X-ray and CT scan and three-dimensional reconstruction before operation. According to the Neer classification, 8 cases were rated as two-part fractures, 15 cases as three-part fractures, and 10 cases as four-part fractures. The interval time between injury and surgery was 1-7 days (mean, 3.67 days). Postoperative functional outcome was evaluated using the Constant-Murley score. ResultsInfection and liquefaction occurred in 2 cases respectively, which was cured after corresponding treatment; primary healing of wound was obtained in the other 29 cases. Five patients had shoulder pain. The patients were followed up 11-47 months (mean, 33 months). The mean time of fracture union was 7.5 months (range, 5-9 months) on the X-ray films. Humeral head necrosis occurred in 2 patients with Neer four-part fractures, and internal fixation failure occurred in 3 patients (2 screw broken and 1 plate broken) with four-part fractures (2 cases) and three-part fractures (1 case), which was cured after conservative treatment. At last follow-up, the mean Constant-Murley score was 70.5 (range, 42-90); the results were excellent in 3 cases, good in 21 cases, moderate in 6 cases, and poor in 3 cases. ConclusionSatisfactory results can be expected for proximal humeral fracture by using of the proximal humeral internal locking system plate based on strict indication and early rehabilitation training.
Objective To compare the effectiveness of locking plate and intramedullary nail in treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. Methods A retrospective analysis was conducted on 86 elderly patients with Neer two- and three-part fractures of the proximal humerus met the selection criteria between January 2015 and December 2018. Forty-six patients were treated with locking plate fixation (locking plate group), and 40 patients with intramedullary nail fixation (intramedullary nail group). There was no significant difference in gender, age, cause of injury, fracture side and type, time from injury to operation, and comorbidities between the two groups (P>0.05). Visual analogue scale (VAS) score, American Shoulder and Elbow Surgery (ASES) score, Constant-Murley score, and shoulder range of motion (forward flexion, abduction, and external rotation) were compared between the two groups. X-ray films were taken to assess the fracture healing, and the neck-shaft angle was measured at 2 days after operation and at last follow-up, and the difference between the two time points was calculated. Results Patients in both groups were followed up 18-40 months, with an average of 30.4 months. There was no significant difference in follow-up time between the two groups (t=−0.986, P=0.327). X-ray films reexamination showed that the fractures of two groups healed, and the healing time was (11.3±2.1) weeks in locking plate group and (10.3±2.0) weeks in intramedullary nail group, which had significant difference between the two groups (t=2.250, P=0.027). The difference of neck-shaft angle was (7.63±7.01)° in locking plate group and (2.85±2.82)° in intramedullary nail group, which had significant difference between the two groups (t=4.032, P<0.001). There was no significant difference in Constant-Murley score, ASES score, VAS score, and shoulder range of motion between the two groups at last follow-up (P>0.05). Complications occurred in 13 cases (28.3%) of locking plate group and in 4 cases (10.0%) of intramedullary nail group, and the difference between the two groups was significant (χ2=4.498, P=0.034). Conclusion Both locking plates and intramedullary nails can be used for the treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. The intramedullary nail fixation surgery is more minimally invasive, which has fewer postoperative complications and faster fracture healing.
Objective To compare the effectiveness of simultaneous and delayed repair of combined full-thickness rotator cuff rupture in proximal humerus fracture. Methods Between January 2015 and January 2017, 44 patients with proximal humerus fractures complicated with full-thickness rotator cuff injuries were included. Twenty-four patients underwent open reduction and internal fixation (ORIF) and rotator cuff repair simultaneously (simultaneous operation group), and 20 patients underwent delayed arthroscopic rotator cuff repair more than 90 days after ORIF (delayed operation group). There was no significant difference in gender, age, cause of injury, and side of injury between the two groups (P>0.05). The fracture healing was observed by X-ray films. The shoulder function was assessed at 3, 6, and 12 months after operation by using the University of California at Los Angeles (UCLA) score. Results All incisions healed by first intention. All patients were followed up 12-24 months (mean, 17 months). Fractures all healed at 3 months after operation in simultaneous operation group. According to UCLA score, the patients had achieved significantly better outcomes in function, active forward flexion, strength of forward flexion, and subjective satisfaction in simultaneous operation group than in delayed operation group at 3, 6, and 12 months after operation (P<0.05). However, there was no significant difference in pain between the two groups (P>0.05). Conclusion For patients with proximal humerus fracture complicated with full-thickness rotator cuff rupture, performing ORIF and simultaneous repair of rotator cuff can improve shoulder function and achieve better effectiveness when compared with delayed repair of rotator cuff.
【摘要】 目的 探讨切开复位肱骨近端内固定锁定系统(proximal humeral internal locking system,PHILOS)治疗老年肱骨近端骨折的疗效。 方法 2008年5月-2009年5月,对22例60岁以上肱骨近端新鲜移位骨折按Neer分型,二部分2例,三部分16例,四部分4例;采用肩前方入路切开复位PHILOS治疗。 结果 22例患者获12~18个月随访,平均14.6个月,采用Constant-Murley评分,优8例,良10例,可3例,差1例,优良率81.4%。 结论 切开复位PHILOS治疗老年肱骨近端骨折疗效肯定。【Abstract】 Objective To discuss the clinical effect of open reduction and internal fixation with the proximal humeral internal locking system (PHILOS) plate in treating elder patients with proximal humeral fracture. Methods From May 2008 to May 2009, we classified 22 cases of fresh displaced proximal humeral fracture according to the Neer classification. All patients were older than 60 years. There were two cases of two-part fracture, 16 cases of three-part fracture and four cases of four-part fracture. The open reduction and internal fixation with PHILOS plate was performed with the anterior deltopectoral approach. Results The 22 patients were followed up for 12 to 18 months with a mean period of 14.6 months. According to Constant-Murley Shoulder Score measurement, eight cases were graded as excellent, 10 good, three fair, and one poor with a excellent and good rate of 81.4%. Conclusion The open reduction and internal fixation with Philos plate is effective in treating elder patients with proximal humeral fracture.