Objective To investigate the clinicalvalue of modified Weaver-Dunn technique in repair of acute acromioclavicular dislocation. Methods From January 1993 to December 1998, 18 cases of acromioclavicular dislocation were treated bymodified Weaver-Dunn technique, and other 17 cases of the same suffering were treated by tension band fixation of the acromioclavicular joints. All of the patients were followed up for 12-36 months before clinical evaluation of the functionof shoulder joints, according to University of Pennsylvanian Shoulder Score System. Results In short term, the shoulder joints recovered much more rapidly in the cases repaired by modified Weaver-Dunn technique; 12, 24 and 36 months after operation, the scores of the cases repaired by modified Weaver-Dunn technique were (1897±67), (193.7±3.6) and (194.7±3.4) respectively according to the Shoulder Score System, while those of the cases treated by tension band fixation were (167.3±7.8), (170.2±6.3) and (165.6±5.9) respectively. The above data indicated that there was significant difference between two groups (P<0.05). Conclusion The modified Weaver-Dunn technique was a better surgical approach than tension band fixation for repair of acute acromioclavicular dislocation.
Objective To compare effectiveness between sequestrum clearance and impacting bone graft and rotational osteotomy on the base of femoral neck via surgical hip dislocation approach for avascular necrosis of femoral head (ANFH) at Association Research Circulation Osseous (ARCO ) stage Ⅲ. Methods A clinical data of 24 patients (27 hips) with ANFH at ARCO stage Ⅲ, who met the inclusion criteria between June 2012 and November 2017, was retrospectively analysed. Of all patients, 12 patients (14 hips) were treated with sequestrum clearance and impacting bone graft via surgical hip dislocation approach (group A); and 12 patients (13 hips) were treated with rotational osteotomy on the base of femoral neck via surgical hip dislocation approach (group B). There was no significant difference in gender, age, disease duration, and affected side, type, and stage of the ANFH between 2 groups (P>0.05). The operation time of each hip and hospitalization stays of each patient in 2 groups were recorded and compared. Imaging examination was performed to observe the blood supply around femoral head, healing of the osteotomy, and the femoral head collapsed. The function of the hip was evaluated by Harris score. Results There was no significant difference in operation time and hospitalization stays (t=–0.262, P=0.797; t=–0.918, P=0.411). All patients were followed up, the follow-up time of group A was 12-28 months (mean, 19.7 months), and the follow-up time of group B was 14-24 months (mean, 17.8 months). The Harris score in groups A and B increased significantly at 6 months and 12 months after operation when compared with preoperative ones (P<0.05). There was no significant difference between 2 groups at 6 months and 12 months (P>0.05). At 12 months after operation, according to the Harris scoring, there were 3 hips of excellent, 7 hips of good, and 4 hips of poor, with the excellent and good rate of 71.4% in group A; there were 5 hips of excellent, 7 hips of good, and 1 hip of poor, with the excellent and good rate of 92.3% in group B. Digital substraction angiography was performed at 1 week after operation and indicated that the blood supply around the femoral head was not destroyed during the operation. Imaging examination after operation showed that the osteotomy of the greater trochanter all healed in 2 groups and the osteotomy of the femoral neck healed in group B. Hip collapse occurred in 2 patients (2 hips) of group A at 12 months after operation. No hip collapse occurred in group B. Conclusion The rotational osteotomy on the base of femoral neck via surgical hip dislocation approach is superior to sequestrum clearance and impacting bone graft in delaying the collapse and improving the hip function for patients with ANFH at ARCO stage Ⅲ.
ObjectiveTo observe the effectiveness of arthroscopic reconstruction of medial patellofemoral ligament (MPFL) with a single bundle of autogenous half peroneal longus tendon, and medial displacement of lateral hemitibial tuberosity for the treatment of recurrent dislocation of patella.Methods Retrospectively analyse the clinical data of 24 patients (24 knees) with recurrent patellar dislocation with tibial tuberosity-trochlear groove distance (TT-TG) values more than 15 mm who were admitted between September 2014 and September 2018. Of which 7 were male and 17 were female; aged 16-35 years old with an average of 25.8 years. The disease duration ranged from 15 to 46 months, with an average of 26.7 months. All patients had a history of knee trauma, and a positive result of apprehension test on the affected knee. All patients underwent the surgery of arthroscopic reconstruction of MPFL with a single bundle of autogenous half peroneal longus tendon, and medial displacement of lateral hemitibial tuberosity. Before and after operation, Kujala score was used to evaluate patellofemoral joint function, Lysholm score was used to evaluate knee joint function; CT and MRI were used to measure and compare the changes of congruence angle (CA), patellar tilt angle (PTA), and lateral patella displacement (LPD) in order to evaluate patella stability.ResultsAll incisions healed by first intention, and no infection or neurovascular injury occurred. Deep vein thrombosis of the lower extremities occurred in 2 cases at 4 and 7 days after operation respectively, and the thrombosis disappeared after symptomatic treatment. All the 24 patients were followed up 12-14 months (mean, 12.9 months). During follow-up, no patellar dislocation reoccurred in the affected knee. At last follow-up, the apprehension test was negative in every patients. The TT-TG, CA, PTA, and LPD were significantly improved when compared with those before operation (P<0.05). The Kujala score and Lysholm score at 1 month and last follow-up were significantly better than those before operation, and the above scores at last follow-up were significantly better than those at 1 month after operation (P<0.05). According to Lysholm score, the patients’ knee joint functions were excellent in 13 cases, good in 10 cases, and fair in 1 case, and the excellent and good rate was 95.8%.ConclusionArthroscopic reconstruction of MPFL with a single bundle of autogenous half peroneal longus tendon combined with medial displacement of lateral hemitibial tuberosity has the advantages of minimal invision and reliable effectiveness. It can be used as one of the effective surgical methods for the treatment of recurrent dislocation of patella.
Sixty-one cases of fracture or dislocation were treated with France-made biopolyester ligament. They consisted of 18 cases of fracture of patella, 13 cases of fracture of olecranon, 8 cases of fracture of distal clavicle, 10 cases of dislocation of acromino-clavicular joint, 6 cases of separation of lower tibio-fibular joint, 3 cases of rapture of cruciate ligament and 3 cases of fracture of upper third of ulna with dislolcation of radial head. The follow-up period lasted from 3 to 12 months with an average of 7.3 months. The result showed that of the 56 follow-up cases, 49 were excellent and 7 were satisfactory. There was no redisplacement occured in this group. The Biopolyester ligament was believed to be a good and safe material for fractures or dislocations and was of good strength of extension and easy to use.
ObjectiveTo develop an instrument for sacroiliac joint fixation with less injury and less complications. MethodsFirstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups:group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. ResultsAccording to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P>0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than that in group C, but there was no significant difference between group B and group C (P>0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. ConclusionThe polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw direction. The simulated application test shows satisfactory fixing effect.
OBJECTIVE: To explore a method of reconstruction of hip joint function after deformed healing of the upper 1/3 of fractured femur as a complication of old fracture dislocation of hip joint. METHODS: A patient with loss of function in hip joint and fusion of knee joint was treated with lock for femur intra-medullary fixation in April 1997. RESULTS: Before operation, the diseased hip joint lost its most functions and the entire lower extremity was disabled because the knee joint had been fused. One year after operation, the follow-up examination revealed that the patient could walk by crutches without discomfort, his daily life and work recovered to normal. CONCLUSION: It is effective to treat a patient suffering old fracture-dislocation of hip joint complicated with deformed healing of the upper 1/3 of fractured femur by means of individualized artificial joint replacement and a prosthesis body with lock for femur intra-medullary fixation, and it is helpful for the development of a new clinical idea to reconstruct functions in the management of some particular cases.
Objective To analyze the treatment of the sternoclavicular joint dislocation by clavicular hook plate and investigate its cl inical value to find a theropy with more safety and stabil ity. Methods Between January 2003 and January 2007, 15 patients with sternoclavicular joint dislocation were involved, among whom there were 12 males and 3 females, aged 28-45 years old (34 on average). There were 12 cases of fall ing injury and 3 cases of vehicle accident injury. The course of disease was 1-12 hours. A total of 2 cases were on the left side and 13 were on the right side. There were 14 casesof anterior dislocation and 1 of posterior dislocation. Two patients were compl icated by acromioclavicular joint dislocationwith no pneumothorax, and 2 patients had a l ittle pleural effusion without any special treatment. As to the damage degree,according to the Grade system, there were 2 cases of type II and 13 cases of type III. Results All patients’ incisionsobtained heal ing by first intention after operation. The X-ray films showed that the reduction of joint dislocation and thelocation of internal fixation were good. All the 15 patients were followed up for 6-18 months (14 months on average). All cases were scored by Rockwood after the operation to assess the curative effect, with 12 excellent, 2 good and 1 fair. There was no wound infection, neurovascular injury, hemopneumothorax, internal fixation failure, redislocation or other side injuries. The anatomical structure as well as appearances and functions were restored. Conclusion The fixation of clavicular hook plate in treating ternoclavicular joint dislocation has superiority over other methods with more stabil ity, less risk and small chances of cardiovascular injury. Besides, the patients can do functional exercises early and the shoulder joint function can be improved to the maximal degree.