west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "臧鑫" 4 results
  • 3D 胸腔镜下切除成人右心房憩室一例

    Release date: Export PDF Favorites Scan
  • Eearly outcomes of totally thoracoscopic minimally invasive aortic valve and double valve replacement

    ObjectiveTo summarize the early outcomes of totally thoracoscopic minimally invasive aortic valve replacement (AVR) and double valve replacement (DVR).MethodsThe clinical data of patients who underwent totally thoracoscopic minimally invasive AVR or DVR in Guangdong Provincial People’s Hospital from April 2020 to January 2021 were retrospectively analyzed. The patients were divided into an AVR group and a DVR group according to the surgical method, and the clinical data of the two groups were compared.ResultsFinally 22 patients were enrolled, including 14 males and 8 females with an average age of 50.0±11.2 years at operation. Eight patients were degenerative disease, 8 were rheumatic heart disease combined with valvular disease, and 6 were bicuspid aortic valve. Out of the 22 patients, 16 underwent AVR alone, and 6 underwent DVR. All patients completed the operation successfully, and there was no death. Perivalvular leakage during surgery occurred in 2 patients. The average cardiopulmonary bypass time was 187.0±39.9 minutes, and aortic cross-clamping time was 117.0 (99.0, 158.0) minutes. Duration of mechanical ventilation and intensive care unit stay was 9.5 (4.8, 18.3) hours and 41.0 (34.0, 64.0) hours, respectively. The volume of chest drainage at the first 24 hours after surgery was 214.0±124.6 mL, and the postoperative hospital stay was 5.5 (4.0, 8.3) days. The cardiopulmonary bypass time and aortic cross-clamping time in the DVR group were longer than those in the AVR group, and the volume of chest drainage at 24 hours after surgery was more than that in the AVR group, with a statistical difference (P<0.05). Echocardiography before hospital discharge showed paravalvular leakage in 1 patient. There was no death during follow-up of 5.9±3.0 months. ConclusionThe early outcome of totally thoracoscopic minimally invasive AVR and DVR is satisfactory, and the approach of surgery is worth exploring.

    Release date: Export PDF Favorites Scan
  • Transapical approach under 3D printing guidance for myectomy in apical hypertrophic cardiomyopathy: A case report

    We reported a 26-year-old male who was diagnosed with apical hypertrophic cardiomyopathy with left ventricular aneurysm. The location of the hypertrophic myocardium and the extent of resection were accurately assessed preoperatively using 3D modeling and printing technology. Myectomy was performed via transapical approach, and the intraoperative exploration was consistent with the description of the preoperative 3D modeling. The patient underwent the surgery successfully without any complications during the hospitalization, and the cardiopulmonary bypass time was 117 min, the aortic cross-clamping time was 57 min, and the hospital stay time was 7 d. The postoperative echocardiography demonstrated left ventricular cavity flow patency. This case provides a reference for the management of patients with apical hypertrophic cardiomyopathy.

    Release date: Export PDF Favorites Scan
  • Preliminary clinical outcomes of the domestic Renatus® balloon-expandable valve system for the treatment of severe aortic stenosis: A prospective cohort study

    Objective To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. MethodsFrom November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. ResultsAll patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. ConclusionTranscatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content