Objective To assess clinical results of three different conduit materials (Gore-Tex synthetic graft,bovinejugular vein and autologous pericardium)for palliative right ventricle-to-pulmonary artery (RV-PA) shunt,and explore the correlation between suitable conduit size and patients’ body weight and McGoon ratio. Methods We retrospectively analyzed clinical data of 24 patients with congenital heart diseases who underwent palliative RV-PA shunt in Department of Pediatric Cardiovascular Surgery of Fu Wai Cardiovascular Hospital from July 2010 to July 2012. There were 11 males and 13 females with their age ranging from 60 days to 6 years and body weight of 10.22±7.41 kg. There were 22 patients with pulmonary atresia and ventricular septal defect (PAVSD),1 patient with tetralogy of Fallot (TOF) and 1 patient with doubleoutlet right ventricle (DORV). Among different conduit materials,autologous pericardium was used for 17 patients,Gore-Texsynthetic graft was used for 5 patients,and bovine jugular vein was used for 2 patients. Conduit size and children’s body weight were analyzed with linear regression,then the equation was corrected with McGoon ratio. Results There was no perioperative death. Postoperative percutaneous saturation (SpO2)of the 24 children was 20.37%±28.33% higher than preoperative SpO2 . Electrocardiogram showed sinus rhythm in all the patients. Twenty-three patients were NYHA classⅡ,and 1 patient was NYHA classⅢ. Postoperative mechanical ventilation time of patients with autologous pericardium were significantly shorter than those of patients with other 2 materials (P=0.017). Sixteen patients were followed up from 10 months to 2 years after discharge,including 12 patients with autologous pericardium,3 patients with Gore-Tex synthetic graft and 1 patient with bovine jugular vein. During follow-up,McGoon ratio of patients with autologous pericardium,Gore-Tex synthetic graft and bovine jugular vein were 1.98±0.46,1.83±0.33 and 1.68 respectively,all of which weresignificantly higher than preoperative McGoon ratio (P<0.05). Six patients underwent radical corrective surgery,including5 patients with autologous pericardium and 1 patient with Gore-Tex synthetic graft. There was no complication directly related to surgery during follow-up. Linear regression was performed to form an equation between suitable conduit size and patients’ body weight:conduit diameter (mm)=0.327×body weight (kg)+4.599. McGoon ratio,conduit size and equationresult were compared to find a practical choice of conduit size. If McGoon ratio<0.8,the first integer greater than the equation result could be chosen. If McGoon ratio>1.2,the first integer less than the equation result could be chosen. If 1.2>McGoon ratio>0.8,the first integer either less or greater than the equation result could be chosen. Group analysis showed that patients who recovered better postoperatively were those whose conduit sizes were closer to equation results as well as equation results corrected with McGoon ratio. Conclusion All the 3 materials can be conventionally chosen for RV-PA shunt. Appropriate conduit size can be decided upon patients’ body weight and McGoon ratio for RV-PA shunt.
Abstract: Objective To evaluate clinical outcomes of tricuspid annuloplasty using a C-type ring made of autologous pericardium for the treatment of functional tricuspid regurgitation (TR). Methods Eleven patients underwent tricuspid annuloplasty in Guizhou Provincial People’s Hospital between March 2009 and January 2011, including 5 male patients and 6 female patients with their age of 32-57 (43.80±12.20) years. There were 3 patients with mild TR, 7 patients with moderate TR, and 1 patient with severe TR. Concomitant procedures included mitral valve replacement and/or aortic valve replacement and/or left atrial thrombectomy. The C-type ring was created using a strip of pericardium after 0.8% glutaraldehyde fixation for 15 minutes. Interrupted horizontal mattress suture was used to secure the C-type ring to the tricuspid annulus. Hear function and echocardiography were examined during follow-up. Results There was no in-hospital death, and the hospital stay was 15-28 (21.10±3.80) days. All the patients were followed up for 8-28 (18.50±7.00)months. There was no death or reoperation because of TR or tricuspid stenosis during follow-up. Ten patients had TR during follow-up, including 9 patients with mild TR and 1 patient with mild to moderate TR, but there was no patient with severe TR. The degree of TR during follow-up was significantly reduced than preoperative degree (Z =-2.81,P<0.05). Preoperative and postoperative right ventricular dimension (19.95±5.11 mm vs. 21.57±12.81 mm,P=0.705) and right atrial dimension(37.55±6.79 mm vs. 35.55±5.22 mm,P=0.317)were not statistically different. Conclusion Tricuspid annuloplasty using a C-type ring made of autologous pericardium has satisfactory clinical outcomes for patients with functional TR.
Objective To summarize the clinical experiences of using selfpericardial patch heightening to treat aortic valve prolapse. Methods From May 2000 to July 2007, seventeen patients with aortic valve prolapse were treated by selfpericardial patch heightening. Fifteen cases had right coronary cusp prolapse, one had left coronary cusp prolapse, and one had no coronary cusp proplapse. There were 10 cases with moderate aortic regurgitation and 7 with severe regurgitation. Autologous pericardium was continuously sutured on the proplapsed cusp by 5-0 or 6-0 Prolene suture. The transesophageal echocardiography(TEE) showed that there was few or mild aortic regurgitation during operation. Preoperative and postoperative echocardiography results were compared. Results The comparison between preoperative and postoperative echocardiography results showed that postoperative left ventricular enddiastolic diameter reduced obviously(38.3±9.6 mm vs. 47.2±10.3 mm,P=0.013);postoperative aortic valve systolic pressure difference reduced(9.8±5.6 mm Hg vs. 10.3±5.3 mm Hg,P=0.792); postoperative aortic valve diastolic pressure difference reduced obviously(45.7±13.6 mm Hg vs. 78.4±19.9 mm Hg,P= 0.000). Echocardiographic examination before discharge showed that 4 cases had no obvious aortic regurgitation, 9 had mild aortic regurgitation and 4 had moderate aortic regurgitation. The average followup time was 32 months(4.74 months). One case underwent aortic valve replacement because of severe aortic regurgitation 4 months later after the operation, and the rest needed no second operation. Conclusion Using selfpericardial patch heightening to treat aortic valve prolapse is a simple operative method, and it is good for young patients or small aortic annulus.
ObjectiveTo investigate the clinical application of fresh autologous pericardial patch transplantation in cardiovascular surgery. MethodFrom January 2008 to December 2014, we used fresh autologous pericardial patch as a repair material in surgical treatment of congenital heart disease, valvular and vascular malformation. A total of 239 patients were included (130 males, 109 females), with a mean age of 0.40±13.80 years ranging from 0.25-69.00 years, including 180 infants. ResultThe time of intensive care unit (ICU) stay was 3-15 days and the time of ventilator-assisted breathing was 4-100 hours. Postoperative atelectasis and pleural effusion occured in 8 patients and was cured successfully by closed thoracic drainage and anti-infection therapy. Nine patients died within 30 days after surgery, including 3 deaths caused by low cardiac output syndrome and acute renal failure, 5 deaths caused by multiple organ failure, and 1 death caused by malignant arrhythmia. All patients had no infective endocarditis, thrombosis, hemolysis, blood vessel stenosis, or calcification of pericardial patch. The cause of death was associated with the primary lesion, but not with transplanted pericardium. We followed up 198 patients for 3-64 months. During follow-up, echocardiography showed no patch graft vegetation, thrombosis, perforation or calcification. ConclusionThe fresh autologous pericardium is a good material for repairing cardiac defects.