west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "采血" 14 results
  • 桡动脉采血后致右手背伸及曲腕功能障碍一例

    Release date:2016-09-07 02:34 Export PDF Favorites Scan
  • Accidental Rupture of Balloon Tube during Endotracheal Intubation in Mechanical Ventilation: Clinical Application of No. 8 Blood Collection Needles for Connection

    ObjectiveTo investigate the clinical effect of No. 8 blood collection needles in connecting broken balloon tubes. MethodsThirty-six patients who underwent mechanical ventilation in the Intensive Care Unit between January 2010 and December 2013 were included as the study subjects. We divided them into two groups. Patients who had accidental rupture of balloon tube during intubation were regarded as the trial group, while those with normal ventilation were regarded as the control group, with each group having 18 patients. The trial group used No. 8 disposable blood collection needles to connect the balloon tubes. Pressure gauge produced in Germany was used to measure the balloon pressure continuously for four hours. Balloon pressure level, balloon leakage and tube dislocation within 24 hours were observed. ResultsThe balloon pressure at different time periods was not significantly different between the two groups (P > 0.05). The leakage rate and complication rate were also not significantly different between the two groups (P > 0.05). ConclusionsUsing No. 8 blood collection needles for connecting broken balloon tubes is effective, easy, and convenient, and the balloon can be maintained at a constant pressure. It solved many previous clinical problems such as high cost, high complication rate, high death rate and medical disputes.

    Release date:2016-10-28 02:02 Export PDF Favorites Scan
  • 库欣综合征伴足溃疡两例

    Release date:2022-01-27 09:35 Export PDF Favorites Scan
  • 130 例肺癌患者机采血小板输注疗效的分析

    目的 分析肺癌患者机采血小板的输注情况,探讨其疗效的影响因素及预防措施。 方法 收集 2010 年 1 月—2016 年 6 月 130 例肺癌患者输注机采血小板 205 例次的临床资料,根据血小板纠正增加指数来评价输注的临床疗效。从疾病类型、性别、年龄、体质量、血小板输注次数以及红细胞悬液输注情况对患者血小板输注疗效进行分析。 结果 130 例肺癌患者 205 例次血小板输注中,158 例次有效,其有效率为 77.1%;小细胞肺癌和非小细胞肺癌有效率分别为 81.5% 和 75.5%,差异无统计学意义(P=0.369);而非小细胞肺癌中的鳞状细胞癌和腺癌有效率分别为 82.3% 和 70.8%,差异无统计学意义(P=0.107);不同性别、年龄和体质量有效率差异无统计学意义(P>0.05);按血小板输注次数为第 1 次、第 2~4 次和第 4 次以上分组比较,有效率差异有统计学意义(P=0.022)。 结论 肺癌患者血小板输注次数可能是影响血小板输注疗效的因素,随着血小板输注次数的增加,发生血小板输注无效的可能性越大。

    Release date:2017-12-25 06:02 Export PDF Favorites Scan
  • 根本原因分析在降低门诊采血护患纠纷中的应用

    目的用根本原因分析法(RCA)分析门诊采血工作中不断增多的护患纠纷的原因,并采取相应的对策,减少护患纠纷的发生。 方法整理分析2014年某院门诊采血室护患纠纷案例发生情况,采用RCA法分析发生原因,得出其原因主要为护患沟通不良、护理人员主动服务意识不强、护理人员操作欠规范、护理人力资源不足、环境因素等,针对各原因于2015年采取综合整改措施。比较分析实施相应防范措施前后的护患纠纷发生情况。 结果2014年护士总数18人,抽血患者总数约为87万例次,发生护患纠纷72例次,护均纠纷发生率为4.0例次/护,患均纠纷发生率约为8.28/10万;2015年护士总数32人,抽血患者总数约为88万例次,发生护患纠纷20例次,护均纠纷发生率为0.6例/护,患均纠纷发生率约为2.27/10万。 结论RCA法能够找出引起护患纠纷的根本原因,优化护理环节,有效降低门诊采血室护患纠纷发生率,提高患者满意度。

    Release date: Export PDF Favorites Scan
  • 真空负压静脉采血的研究进展

    【摘要】 真空负压静脉采血法,使血标本在采集、运输、保存环节处于全封闭状态,能最大限度保持血液标本的原始状态,保护医护人员免受职业伤害,可提高一次性采血成功率,是静脉血标本采集的一大改革。由于其具有使实验数据准确可靠、无污染、工作省时省力等优点,已被广泛使用。近年来,研究人员就真空负压采血的临床应用进行了大量的实践,对采血针的选择、压脉带的使用、穿刺技术及方法改进、采血质量控制、护理措施等进行了一系列研究。医务人员加强采血知识的学习可减少采血并发症,保证标本质量,减少医疗资源的浪费和减轻患者痛苦。

    Release date:2016-09-08 09:26 Export PDF Favorites Scan
  • 真空采血管在老年难治性窦道伤口治疗中的应用

    【摘要】 目的 总结真空采血管在老年难治性窦道伤口治疗中的应用效果。 方法 回顾性分析2009年12月—2010年9月收治因肾癌和神经源膀胱手术后4例老年难治性窦道伤口患者的病例资料,总结采用真空采血管进行伤口治疗的方法及疗效。 结果 患者经过12~14 d后伤口闭合,上皮覆盖,达到伤口全部愈合。 结论 采用真空采血管治疗老年难治性窦道伤口,方法简便,费用低廉,可有效促进伤口愈合。

    Release date:2016-09-08 09:26 Export PDF Favorites Scan
  • 以顽固性低钾血症为首发症状的 MRI阴性库欣病一例

    Release date:2017-01-18 08:50 Export PDF Favorites Scan
  • 不同厂商紫头真空采血管的血常规结果比对

    目的:对不同厂商的紫头真空采血管进行评估,其血常规结果是否有差异。方法:同时使用美国BD公司和成都瑞琦公司生产的紫头真空采血管采集40份新鲜全血标本,分别在自动血液分析仪XE-2100进行检测,再进行白细胞(WBC)、红细胞(RBC)、血红蛋白(HGB)、血小板(PLT)等参数的相关性比较。结果:WBC、RBC、HGB和PLT等参数的差异百分率分别为:0.49%、0.05%、0.13%和1.01%;相关系数(r)分别是:0.9985、0.9964、0.9966和0.9932;t检验的P值分别是:0.9706、0.9020、0.9679、0.9061,均gt;0.05。结论:真空采血管普遍应用于临床标本的采集,由于真空度、抗凝剂的量、管壁的质量对血常规结果均有影响,不同厂商的真空采血管质量不完全相同,通过新鲜全血的结果比对,美国BD公司和成都瑞琦公司生产的紫头真空采血管的血常规结果相关性好,其相关系数均在0.99以上,P值均gt;0.05,无显著性差异,差异百分率小,均lt;±2.0%的可接受范围,表明可用于临床。

    Release date:2016-09-08 09:54 Export PDF Favorites Scan
  • Vacuum Sampling versus Disposable Needle Sampling via Femoral Vein in Infants of China: A Systematic Review

    Objective To evaluate the effect and safety of infantile femoral vein blood sampling with vacuum versus disposable needle. Methods Such databases as VIP, CNKI, CBM, Google Academic and Wanfang data were searched to collect the randomized controlled trials (RCTs) about infantile femoral vein blood sampling with vacuum versus disposable needle published from January 2000 to July 2010. The studies were screened according to the inclusive and exclusive criteria, the data were extracted, the methodology quality was assessed, and meta-analysis was conducted by using RevMan 5.0 software. Results A total of 15 RCTs were included. Of 3 490 patients in all, 1 770 were in the treatment group and 1 726 were in the control group. The baseline conditions were reported in 14 studies, and the random methods were mentioned in 11 RCTs. All studies didn’t report the allocation concealment and blind method. Only 2 RCTs reported separately that, the degree of neonatal pain was lower in the treatment group (Plt;0.01), and the satisfaction of parents was higher in the treatment group (Plt;0.01). Four RCTs compared the sampling time between the two groups without meta-analysis mentioned due to the disunity of standard, only the descriptive outcomes showed a shorter time in the treatment group. The meta-analysis showed that, compared with the control group, the reject rate of sample quality was lower (RR=0.20, 95%CI 0.15 to 0.26), the success rate of one time sampling was higher (RR=1.20, 95%CI 1.16 to 1.24), the injury of local tissue was slighter (RR=0.62, 95%CI 0.45 to 0.86), and the iatrogenic contamination was lower (RR=0.62, 95%CI 0.45 to 0.86) in the treatment group. Conclusion This review shows that the vacuum sampling is superior to the disposable needle sampling for domestic infantile femoral vein blood collection. Due to the low quality of the included studies with high possibility of bias, this conclusion needs to be further verified by performing more high-quality studies.

    Release date:2016-09-07 11:01 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content