目的:探讨蛋白酶体抑制剂——硼替佐米对初治多发性骨髓瘤的疗效及对移植造血干细胞采集的影响。方法:对一例初发的中年男性多发性骨髓瘤患者使用硼替佐米+地塞米松+反应停(VTD)的方案进行化疗,获得缓解后采集外周血造血干细胞。结果:应用以硼替佐米为基础的方案治疗3个疗程后,患者即获得完全缓解;完成4个疗程化疗后成功采集足够数量的外周血造血干细胞;完成6个疗程化疗后,进入维持治疗,至今已完全缓解17个月。治疗过程中除恶心、呕吐外无其他明显不良反应。结论:硼替佐米用于初治多发性骨髓瘤有良好的治疗效果,不良反应少,不影响造血干细胞采集。
Objective To investigate the assembl ing and cl inical appl ication of the video output system util izing teaching sight glass of surgical microscope. Methods Between June 2009 and April 2010, 10 patients with craniocervical junction malformation were treated by the method of transoral-transpharyngeal approach with the microscope and videooutput system under the direct vision. There were 6 males and 4 females with an average age of 32 years (range, 13-52 years). Three cases had the history of injury and 7 cases had no history of definite injury. The disease duration was from 10 months to 12 years (median, 5 years). The main cl inical symptoms were brevicoll is or torticoll is; 2 patients had malformation appearance and 4 patients had occi put-cervical pain. The physical examination showed that all patients had the symptoms that upper cervical cord was damaged; the imaging examination showed that all patients had basilar invagination, atlantoaxial dislocation, and ossification. Before and after operations, the functions of nerve were evaluated by Japanese Orthopaedic Association (JOA) scoring, the improvement rate was calculated to evaluate the efficacy. Results By the video output system assembly, 15.1 mill ion pixels high-definition images could be collected and reached 1 920 × 1 080 pixels video camera, so assistants or medical students could watch the cl inical operation directly. All patients had no neural injury or cerebrospinal fluid leakage during operation. Basilar invagination and atlantoaxial dislocation were corrected. Infection at incision occurred in 1 patient; other incisions healed by first intention without early compl ication. All patients were followed up 6-16 months (mean, 13.5 months). The average JOA score was increased from 10.2 preoperatively to 15.5 at 6 months postoperatively with an improvement rate of 77.9%. At 12 months after operation, bony fusions were achieved. Conclusion The miscroscope and video output system can improve the effectiveness of the original surgical microscope. It makes visual fields much clearer and operations more accuratewith a few compl ications.
This paper reports the study and design of a visualization system of the ultrasonic rhinitis therapeutic apparatus with the function of endoscopic sinus. On Linux operating platform, we captured the video data of a video capture card that connected the endoscopic sinus using Video4Linux (V4L2) that was provided by the operating system. The video images were displayed by Qt. The visualization system solved the problem that the current ultrasonic rhinitis therapeutic apparatus had to rely on the large and expensive endoscopy equipment. And this simplified the doctors' operation, met the need of monitoring nasal cavity in the process of operating, greatly reduced the costs of treatment and would contribute to the promotion of the instrument. As a result, it has been tested that the nasal endoscopic image achieved by the system is clear and smooth, and fully meet the clinical needs of ultrasonic treatment of rhinitis.
The growing rate of public health problem for increasing number of people afflicted with poor sleep quality suggests the importance of developing portable sleep electroencephalogram (EEG) monitoring systems. The system could record the overnight EEG signal, classify sleep stages automatically, and grade the sleep quality. We in our laboratory collected the signals in an easy way using a single channel with three electrodes which were placed in frontal position in case of the electrode drop-off during sleep. For a test, either silver disc electrodes or disposable medical electrocardiographic electrodes were used. Sleep EEG recorded by the two types of electrodes was compared to each other so as to find out which type was more suitable. Two algorithms were used for sleep EEG processing, i.e. amplitude-integrated EEG (aEEG) algorithm and sample entropy algorithm. Results showed that both algorithms could perform sleep stage classification and quality evaluation automatically. The present designed system could be used to monitor overnight sleep and provide quantitative evaluation.
In order to investigate the effect of deep brain stimulation on diseases such as epilepsy, we developed a closed-loop electrical stimulation system using LabVIEW virtual instrument environment and NI data acquisition card. The system was used to detect electrical signals of epileptic seizures automatically and to generate electrical stimuli. We designed a novel automatic detection algorithm of epileptic seizures by combining three features of field potentials: the amplitude, slope and coastline index. Experimental results of rat epileptic model in the hippocampal region showed that the system was able to detect epileptic seizures with an accuracy rate 91.3% and false rate 8.0%. Furthermore, the on-line high frequency electrical stimuli showed a suppression effect on seizures. In addition, the system was adaptive and flexible with multiple work modes, such as automatic and manual modes. Moreover, the simple time-domain algorithm of seizure detection guaranteed the real-time feature of the system and provided an easy-to-use equipment for the experiment researches of epilepsy control by electrical stimulation.
Abdominal imaging is one of the important clinical applications of magnetic resonance imagining, but image degradation due to respiratory motion remains a major problem. Retrospective respiratory navigator gating technique is an effective approach to alleviate such degradation but is subject to long scan time and low signal-to-noise ratio (SNR) efficiency. In this study, a modified retrospective navigator gating technique with variable over-sampling ratio acquisition and weighted average reconstruction algorithm is presented. Experiments in phantom and the imaging results of seven volunteers demonstrated that the proposed method provided an enhanced SNR and reduced ghost-to-image ratio compared to the conventional method. The proposed method can also be used to reduce imaging time while maintaining comparable image quality.
In recent years, wearable devices grew up gradually and developed increasingly. Aiming at the problems of skin sensibility and the change of electrode impedance of Ag/AgCl electrode in the process of long-term electrocardiogram (ECG) signal monitoring and acquisition, this paper discussed in detail a new sensor technology–fabric electrode, which is used for ECG signal acquisition. First, the concept and advantages of fabric electrode were introduced, and then the common substrate materials and conductive materials for fabric electrode were discussed and evaluated. Next, we analyzed the advantages and disadvantages from the aspect of textile structure, putting forward the evaluation system of fabric electrode. Finally, the deficiencies of fabric electrode were analyzed, and the development prospects and directions were prospected.
Objective To explore the application value of standardized patient (SP)-based teaching method in the teaching of medical history taking for international students. Methods During the autumn semester of 2017, 96 international medical students were randomly divided into two groups, with 48 students in the SP-based teaching group and 48 students in the conventional teaching group. The test scores of medical history taking in English in internal medical practice of the two groups were compared. The teaching feedback from the international students was collected and evaluated by online questionnaire survey. Results The scores of medical history taking examination in internal medical practice of the students using SP-based teaching method were higher than those of the students using conventional teaching method (86.5±9.7 vs.78.2±10.6), and the difference was statistically significant (t=3.983, P<0.001). According to the questionnaire analysis, in terms of whether the current teaching method could enhance learning interest, improve communication ability, promote clinical skills, train clinical thinking, and highlight humanistic care, students with positive views in the SP-based teaching group accounted for 92.86%, 97.62%, 85.71%, 90.48%, and 95.24%, respectively, while students with positive views in the conventional teaching group accounted for 90.00%, 87.50%, 82.50%, 77.50%, and 97.50%, respectively, and the differences were not statistically significant (P>0.05). Conclusions Well-trained SP has a good application value in clinical practice of internal medicine and diagnostics teaching for international students. SP-based teaching method has been accepted and supported by the majority of international medical students who have experienced it.