To evaluate the cl inical effect of pedical screw systems fixed between lumbar and il ium for treatment of sacral fractures. Methods From June 2003 to June 2009, 21 cases of sacral fracture (29 sides including monolateral 13 cases and bilateral 8 cases) were treated with pedical screw systems to have reduction and fixation. There were 12 males and 9 females, aging 23-59 years (38.2 years on average). Fractue was caused by traffic accident in 12 cases, by fall ingfrom height in 7 cases, and by crash in 2 cases. Screws were inserted into lumbar pedicles and il iac crests. Decompression was used in 4 cases compl icated by sacral nerves injury, and reductions and fixations were used in 12 cases compl icated anterior pelvic or acetabulum injury. The preoperative proximal displacement at the injured side of the pelvis was (16.29 ± 6.47) mm compared with contralateral pelvis. Results All incisions healed primarily with no compl ication of infection. Twentyone patients were followed up 6 months to 6 years. Cl inical heal ing time of fracture was 6-9 weeks. In 4 cases compl icated by S1 or S2,3 nerves injury, the function recovered completely after 4-9 weeks. In other 17 patients, no compl ication of intraoperative nerve injury occurred. All patients could walk and squat after 6-12 weeks of operation. No breakage or displacement of implant occurred. The postoperative proximal displacement at the injured side of the pelvis was (3.51 ± 0.68) mm compared with contralateral pelvis, showing significant difference (P lt; 0.01) when compared with preoperative one. Conclusion It is a novel choice to have reduction and internal fixation for sacral fracture with pedical screw systems fixed between lumbar and il ium. The strict regulation of indication and skill is the key to prevent compl ication.
Objective To investigate the biomechanical differences of three internal fixation approaches, namely improved Galveston (IG), reconstruction plate (RP), and il iosacral screw (LS) to the posterior pelvic ring fracture dislocation and provide experimental evidence for the cl inical appl ication of proper internal fixation method. Methods Six donatedfresh adult cadaver pelvic specimens (age averaged 45 years old) were numbered randomly and their normal biomechanics were tested by the measure instrument (MTS855 Mini-Blonix). The displacement values of normal pelvis were measured under the vertical compression (800 N) and reverse direction compression (8 N·m). Then they were made into left Denis I pelvic fracture and fixed with the IG, RP, and LS, respectively, in different orders. Biomechanics test was conducted on the fixed pelvis from both the vertical and the reversed directions. Results Concerning the direction of vertical ity and torsion, the order of fracture displacement from small to large was the normal pelvis, LS, IG and RP. There was no significant difference between LS and the normal pelvis (P gt; 0.05), and the differences between other tow groups were significant (P lt; 0.05). Conclusion The LS fixation can provide better stabil ity for posterior pelvic ring fracture dislocation when compared with IG and RP.
目的 通过对保留不同平面骶骨的新鲜人骨盆模型进行生物力学测试,分析骶骨切除平面与骨盆稳定性的关系,明确骶骨切除保留至何种程度时需行腰骶髂稳定性重建。 方法 选用6具正常成年男性新鲜尸体腰5-骨盆标本,采用200 N增量分级加载,以1.4 mm/min速率平稳加载直至1 000 N,依次测试保留完整骶骨及不同平面骶骨切除骨盆模型的最大主应力、剪切应力、位移及刚度变化,比较各组间的差异。最后测量1/2S1组骨盆环的极限载荷,记录骨折发生部位和骨折类型。 结果 随骶骨切除平面增高,最大主应力、剪切力及骶骨下沉位移在各测试点均有不同程度增大,骨盆的轴向刚度不断减小。当切除平面达骶1时,变化明显,尤其以经过骶1下1/4~下1/2时变化显著,与完整骶骨组比较,差异有统计学意义(P<0.05)。骶1椎体下1/2平面切除后,骨盆的极限载荷是(2 375.97 ± 162.41)N,骨盆的破坏形态为经骶髂关节或骶椎的骨折。 结论 骶骨切除范围与骨盆环的稳定性密切相关,随着骶骨切除平面升高,残留骶髂关节各种应力急剧增高,骨盆的稳定性明显下降。当骶骨切除涉及骶1椎体时,极易发生骨折,需要进行腰骶髂局部重建以增强骶髂关节的稳定性。
Objective To review the development of the reconstruction methods following total sacrectomy, and to provide reference for finding a better reconstruction method following total sacrectomy. Methods The case reports and biomechanical and finite element studies of reconstruction following total sacrectomy at home and abroad were searched. Development and current situation were summarized. Results After developing for nearly 30 years, great progress has been made in the reconstruction concept and fixation techniques. The fixation methods can be summarized as the following three strategies: spinopelvic fixation (SPF), posterior pelvic ring fixation (PPRF), and anterior spinal column fixation (ASCF). SPF has undergone technical progress from intrapelvic rod and hook constructs to pedicle and iliac screw-rod systems. PPRF and ASCF could improve the stability of the reconstruction system. Conclusion Reconstruction following total sacrectomy remains a challenge. Reconstruction combining SPF, PPRF, and ASCF is the developmental direction to achieve mechanical stability. How to gain biological fixation to improve the long-term stability is an urgent problem to be solved.
Objective To evaluate the effectiveness of lumbopelvic fixation using the combination of closed multi-axial screws (CMAS) iliosacral fixation system and the posterior segmental spinal fixation for unstable sacral fractures. Methods Between January 2013 and November 2014, 25 patients (39 sides) with unstable sacral fractures were treated with lumbopelvic fixation using the combination of CMAS iliosacral fixation system and the posterior segmental spinal fixation. There were 17 males and 8 females, aged 19-55 years (mean, 33.9 years). The causes were traffic accident injury in 15 cases, falling injury from height in 8 cases, and crushing injury in 2 cases. The interval of injury and operation was 1-13 days (mean, 3.5 days). Fracture was classified as Denis type I in 2 sides, type II in 20 sides, and type III in 17 sides; nerve injury was rated as Gibbons grade I in 2 cases, grade II in 2 cases, grade III in 7 cases, and grade IV in 9 cases. The reduction quality was evaluated by Matta criterion, the clinical function outcome by Majeed, and nerve function by Gibbons criterion. Results The average operation time was 110 minutes (range, 80-150 minutes). The average blood loss was 570 mL (range, 250-1 400 mL). Superficial wound infection occurred in 2 patients, and was cured after debridement and antibiotic therapy. All patients were followed up for an average of 18 months (range, 15-22 months). Postoperative X-ray and CT examination showed clinical healing of sacral fractures at 8-12 weeks after operation (mean, 10 weeks). The mean removal time of internal fixation was 13 months (range, 12-20 months). No screw loosening and fracture, adhesion of internal fixation to surrounding tissue, and obvious electrolysis phenomenon occurred. According to Matta criterion, reduction was rated as excellent in 32 sides, good in 6 sides, fair in 1 side, and the excellent and good rate was 97.5%. According to Majeed functional scoring at last follow-up, the mean score was 84.7 (range, 64-98); the results were excellent in 18 cases, good in 5 cases, and fair in 2 cases, and the excellent and good rate was 92.0%. The nerve function was significantly improved when compared with preoperative one; nerve injury was rated as Gibbons grade I in 8 cases, grade II in 8 cases, grade III in 3 cases, and grade IV in 1 case. Conclusion Lumbopelvic fixation using the combination of CMAS iliosacral fixation system and the posterior segmental spinal fixation is a relatively effective fixation for unstable sacral fractures. Not only is the fracture fixation rigid for early full weight-bearing, but also nerve decompression can be performed which facilitates nerve function recovery.
ObjectiveTo investigate the effectiveness of percutaneous double-segment lengthened sacroiliac screws internal fixation assisted by three-dimensional (3D) navigation technology in treatment of Denis type Ⅱ and Ⅲ sacral fractures. Methods A clinical data of 45 patients with the Denis type Ⅱ and Ⅲ sacral fractures admitted between January 2017 and May 2020 was retrospectively analyzed. There were 31 males and 14 females, with an average age of 48.3 years (range, 30-65 years). The pelvic fractures were all high energy injuries. According to the Tile classification standard, there were 24 cases of type C1, 16 cases of type C2, and 5 cases of type C3. The sacral fractures were classified as Denis type Ⅱ in 31 cases and type Ⅲ in 14 cases. The interval between injury and operation was 5-12 days (mean, 7.5 days). The lengthened sacroiliac screws were implanted in S1 and S2 segments respectively under the assistance of 3D navigation technology. The implantation time of each screw, the intraoperative X-ray exposure time, and the occurrence of surgical complications were recorded. After operation, the imaging reexamination was used to evaluate the screw position according to Gras standard and the reduction quality of sacral fractures according to Matta standard. At last follow-up, the pelvic function was scored with Majeed scoring standard. Results The 101 lengthened sacroiliac screws were implanted with the assisting of 3D navigation technology. The implantation time of each screw was 37.3 minutes on average (range, 30-45 minutes), and the X-ray exposure time was 46.2 seconds on average (range, 40-55 seconds). All patients had no neurovascular or organ injury. All incisions healed by first intention. The quality of fracture reduction was evaluated according to Matta standard as excellent in 22 cases, good in 18 cases, and fair in 5 cases, and the excellent and good rate was 88.89%. The screw position was evaluated according to Gras standard as excellent in 77 screws, good in 22 screws, and poor in 2 screws, and the excellent and good rate was 98.02%. All patients were followed up 12-24 months (mean, 14.6 months). All fractures healed and the healing time was 12-16 weeks (mean, 13.5 weeks). Pelvic function was evaluated according to Majeed scoring standard as excellent in 27 cases, good in 16 cases, fair in 2 cases, and the excellent and good rate was 95.56%. Conclusion Percutaneous double-segment lengthened sacroiliac screws internal fixation for the treatment of Denis type Ⅱ and Ⅲ sacral fractures is minimally invasive and effective. With the assistance of 3D navigation technology, the screw implantation is accurate and safe.
ObjectiveTo study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. MethodsA retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. ResultsThe CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545±0.248) cm and (1.060±0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818±1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1 800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months (mean, 21 months). According to Enneking standard, the results were excellent in 9 cases, good in 20 cases, fair in 5 cases, and poor in 2 cases at 3 months after operation. There were 10 cases of dysfunction of urination and defecation, 2 cases of tumor recurrence, and 3 cases of death after surgery. ConclusionCTA and three-dimensional reconstructions technique can accurately measure the external diameter of aortaventralis and arteria iliaca communis and the distance between low renal artery and abdominal aortic bifurcation and offer great help to choose appropriate balloon and locate the balloon during surgery. The balloon blocking technique under the assistance of CTA can obviously reduce intraoperative blood loss and tumor recurrence, supply a clear view in surgery and shorten the operation time.
目的 探讨“医护一体化”疼痛管理模式在骶骨肿瘤患者围手术期的应用效果。 方法 以2011年1月-10月选取的23例骶骨肿瘤患者作为研究对象,根据科室疼痛管理的规范化流程,在“医护一体化”工作模式下由护士进行疼痛评估、医生护士共同制定疼痛管理方案,护士落实个体化疼痛护理措施、规范用药指导、综合心理护理和镇痛效果反馈等。 结果 经“医护一体化”疼痛管理,患者疼痛情况大为改观,20例患者疼痛评分<3分,占总例数的87.0%,由入院初期的中、重度疼痛患者居多转变为轻度疼痛患者占主导。 结论 运用医护一体化多模式疼痛管理可以有效减轻患者疼痛,提高护理服务质量。