find Author "鲁兴" 2 results
  • Risk of micro-fracture in femoral head after removal of cannulated screws for femoral neck fracture

    ObjectiveTo explore the changes of bone and risk of micro-fracture in femoral head after removal of cannulated screws following femoral neck fracture healing under the impact force of daily stress.MethodsA total of 42 specimens of normal hip joint were collected from 21 adult fresh cadaveric pelvic specimens. Wiberg central-edge (CE) angle, bone mineral density, diameter of femoral head, neck-shaft angle, and anteversion angle of femoral neck were measured. Then, the 3 cannulated screws were implanted according to the AO recommended method and removed to simulate the complete anatomical union of femoral neck fracture. The morphology of screw canal in the femoral head was observed by CT. Finally, the specimens were immobilized vertically within the impact device in an upside-down manner, and the femoral heads were impacted vertically. Every specimen was impacted at 200, 600, and 1 980 N for 20 times with the impacting device. After impact, every specimen was scanned by CT to observe the morphology changes of screw canal in the femoral head. Micro-fractures in the femoral head could be confirmed when there was change in the morphology of screw canal, and statistical software was used to analyze the risk factors associated with micro-fractures.ResultsAfter impact at 200 and 600 N, CT showed that the morphology of screw canal of all specimens did not change significantly compared with the original. After impact at 1 980 N, there were protrusion and narrowing in the screw canal of the 22 femoral head specimens (11 pelvic specimens), showing obvious changes compared with the original screw canal, indicating that there were micro-fractures in the femoral head. The incidence of micro-fracture was 52.38% (11/21). logistic regression results showed that there was correlation between micro-fracture and bone mineral density (P= 0.039), but no correlation was found with CE angle, diameter of femoral head, neck-shaft angle, and anteversion angle (P>0.05).ConclusionThe micro-fractures in the femoral head may occur when the femoral head is impacted by daily activities after removal of cannulated screws for femoral neck fractures, and such micro-fractures are associated with decreased bone density of the femoral head.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • EyresⅢA型喙突骨折的手术治疗

    目的 总结Eyres ⅢA型喙突骨折手术治疗方法及效果。 方法 2010年8月-2014年8月,采用锁骨钩钢板固定肩关节联合喙突骨折解剖复位后2枚空心钉固定治疗4例Eyres ⅢA型喙突骨折患者。男3例,女1例;年龄36~41岁,平均39岁。致伤原因:交通事故伤3例,机器伤1例。伤后至入院时间2~12 h,平均6 h。 结果 术后患者切口均Ⅰ期愈合,无感染、皮肤坏死等术后早期并发症发生。4例均获随访12个月。术后4个月取出锁骨钩钢板,保留空心钉。术后8个月CT示骨折完全愈合。随访期间无肩关节再脱位,内固定物松动、断裂,继发骨折等发生。术后12个月根据Neer肩关节功能评分标准评分为83~87分,平均85分。 结论 对于Eyres ⅢA型喙突骨折,采用锁骨钩钢板固定肩关节联合喙突骨折解剖复位后2枚空心钉固定可行且疗效满意。

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content