west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "黄功成" 3 results
  • Influence of High Activity of CYP2C9 and VKORC on Warfarin Anticoagulation after Heart Valve Replacement

    ObjectiveTo investigate the influence of high activity of CYP2C9 (Cytochrome P450 proteins 2C9)and VKORC (Vitamin K epoxide reductase C)on warfarin anticoagulation of patients after heart valve replacement (HVR). MethodsFrom February 2010 to May 2013, 40 patients with high activity of CYP2C9 and VKORC underwent HVR in the Department of Cardiac Surgery, the First Affiliated Hospital of Zhengzhou University. There were 18 male and 22 female patients with their age of 40-51 (45.18±2.93)years. There were18 patients receiving mitral valve replacement (MVR), 14 patients receiving MVR and tricuspid valvuloplasty (TVP), and 8 patients receiving double valve replacement (DVR). Depen-ding on whether they received preoperative genetic polymorphism detection of CYP2C9 and VKORC1, all the patients were divided into 2 groups with 20 patients in each group. Patients in group A didn't receive preoperative genetic polymorphism detection of CYP2C9 and VKORC1, while patients in group B received preoperative genetic polymorphism detection of CYP2C9 and VKORC1. Postoperatively, periodic examination of international normalized ratio (INR)was performed to adjust warfarin dosage. Time to reach expected INR value and morbidity were collected. All the patients were followed up for 3-12 months after discharge. Monthly telephone follow-up was performed to record INR values, morbidity and general recovery. ResultsPostoperatively, in group A, 2 patients had cerebral infarction, 2 patients had popliteal artery throm-bosis, 1 patient had pulmonary embolism, and 1 patient had thrombosis in the annulus. Expected INR was achieved 15-20 days after warfarin treatment among the other 14 patients without thromboembolism. Three months after surgery, CYP2C9 and VKORC1 gene polymorphism was examined to find 17 patients with positive CYP2C9*1/*1 (*2CC/*3AA)and positive VKORC1-1639 GA, and 3 patients with positive CYP2C9*1/*1 (*2CC/*3AA)and positive VKORC1-1639 GG. In Group B, patients received aspirin (100 mg/d)and low molecular heparin (0.4 ml/d)in addition to warfarin since the second posto-perative day. Expected INR was achieved 5-9 days after warfarin treatment, and then aspirin and low molecular heparin were discontinued. During the 6 months follow-up period, no obvious thromboembolism was found, and only 1 patient had epistaxis who was cured with nasal tamponade. ConclusionPreoperative detection of genetic polymorphisms of CYP2C9 and VKORC1 can provide important guidance for warfarin anticoagulation after HVR.

    Release date: Export PDF Favorites Scan
  • 罕见右心房浸润性脂肪瘤合并右心房血栓一例

    Release date:2016-10-02 04:56 Export PDF Favorites Scan
  • Short-term results of valve-in-valve transcatheter aortic valve implantation in patients with degenerated bioprosthesis

    Objective To summarize the short-term results of valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in the treatment of bioprosthetic valve failure after aortic valve replacement. Methods We reviewed the clinical data of patients who underwent ViV-TAVI from 2021 to 2022 in the First Affiliated Hospital of Zhengzhou University. The valve function was evaluated by echocardiography before operation, immediately after operation and 3 months after operation. The all-cause death and main complications during hospitalization were analyzed. Results A total of 13 patients were enrolled, including 8 males and 5 females with a mean age of 65.9±8.5 years, and the interval time between aortic valve replacement and ViV-TAVI was 8.5±3.4 years. The Society of Thoracic Surgeons mortality risk score was 10.3%±3.2%. None of the 13 patients had abnormal valve function after operation. The mean transvalvular differential pressure of aortic valve was decreased (P<0.001), the peak flow velocity of aortic valve was decreased (P<0.001), the left ventricular ejection fraction was not changed significantly (P=0.480). There were slight perivalvular leakage in 2 patient and slight valve regurgitation in 3 patients. Three months after operation, the mean transvalvular pressure difference and peak flow velocity of aortic valve in 12 patients were significantly different from those before operation (P≤0.001). Conclusion This study demonstrates that ViV-TAVI for the treatment of bioprosthetic valve failure after aortic valve replacement is associated with sustained clinical and functional cardiovascular benefits, the short-term results are satisfactory.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content