  • A bench study of the auto adjusted triggering in noninvasive mechanical ventilators

    Objective To evaluate the effect of auto adjusted triggering mechanism on the triggering balance of sensitivity and anti-interference in non invasive ventilator field. Methods Taking the breathing simulator as the experimental platform, for the same ventilator, the experiments of "automatic adjustment mode" and "manual adjustment mode" were carried out in a self-control manner, comparing the sensitivity and anti-interference indexes of the experimental group and the control group in the triggering stage. The results were statistically analyzed. Results In case of large air leakage, for ventilator of "A40", the group of "automatic adjustment mode" presented auto-triggered cycle and the group of "manual adjustment mode" (the inspiratory trigger sensitivity was adjusted to 5 to 9 L/min) could provide breathing assistance ventilation. While for ventilator of "VENT", both the group of "automatic adjustment mode" and the group of "manual adjustment mode" (the inspiratory trigger sensitivity was adjusted to 1 to 8 arbitrary unit) appear auto-triggered cycle. In case of medium air leakage, for ventilator of "A40", the trigger delay time, trigger pressure and trigger work of the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 3 to 5 L/min) were significantly less than those of the "automatic adjustment mode" group, and the trigger delay time, trigger work of the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 8 to 9 L/min) were significantly higher than those of the "automatic adjustment mode" group; While for ventilator of "VENT", compared with the inspiratory trigger sensitivity of the "automatic adjustment mode" group and the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 4 arbitrary unit), the trigger delay time, trigger pressure and trigger work were not statistically significant. In case of small air leakage, for ventilator of "A40", the trigger delay time and trigger work of the "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 2 to 6 L/min) were significantly less than those in the "automatic adjustment mode" group, and the trigger pressure of "manual adjustment mode" group (the inspiratory trigger sensitivity was adjusted to 2 to 5 L/min and 7 L/min) was significantly lower than that of "automatic adjustment mode" group. While for ventilator of "VENT", the trigger delay time, trigger pressure and trigger work of the "manual adjustment" group (the inspiratory trigger sensitivity was adjusted to 1 to 2 arbitrary unit) were less than those of the experimental group, and they were statistically significant. Conclusions In case of large air leakage, ventilator of "VENT" can not provide breathing assistance ventilation no matter which inspiratory trigger mode. While ventilator of "A40" should be used the "manual adjustment mode", and adjust the inspiratory trigger sensitivity to the less sensitive arbitrary unit to increase its performance of anti-interference. In case of medium air leakage, for both ventilator of "A40" and ventilator of "VENT", it is better to use "automatic adjustment" mode for breathing assistance ventilation. In case of small air leakage, for both ventilator of "A40" and ventilator of "VENT", it is better to use "manual adjustment" mode for breathing assistance ventilation and we should adjust the inspiratory trigger sensitivity to the higher sensitive arbitrary without auto-triggered cycle.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content