west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "CAI Xiaowei" 4 results
  • Proportion of pulmonary valve annulus: A new predictive index for transannular patch in repair of tetralogy of Fallot

    ObjectiveTo investigate if the ratio of pulmonary valve annulus, which is the proportion of pulmonary valvular annulus size to total size of aortic valvular annulus and pulmonary valvular annulus, can better guide the choice of surgical approach than the value of z.MethodsA retrospective analysis was made for 254 patients who underwent total correction of tetralogy of Fallot in Guangdong General Hospital between January 2016 and January 2018. There were 154 males and 100 females with an average age of 14.60±18.76 years. The patients were categorized into two groups, a transannular patch group (TAP, n=164) and a non-TAP group (n=90). The sizes of pulmonary and aortic valvular annulus were evaluated in each group, and the cutoff value of proportion of pulmonary valvular annulus for TAP was calculated.ResultsBoth proportion of pulmonary valvular annulus and z-scores were smaller in the TAP group than those in the non-TAP group (0.29±0.06 vs. 0.36±0.06, P<0.001; –4.04±2.13 vs. –2.06±1.84, P<0.001, respectively). In receiver operating characteristics analyses, proportion of pulmonary valvular annulus and the z-score cutoff values were 0.353 (area under the curve 0.781, 95%CI 0.725–0.831) and –2.13 (area under the curve 0.766, 95%CI 0.709–0.817), respectively, demonstrating that the proportion of pulmonary valvular annulus was a more powerful diagnostic tool as a predictor of TAP.ConclusionOur results suggest that the proportion of pulmonary valvular annulus is an effective predictor for TAP and can be easily applied to clinical practice.

    Release date:2019-03-29 01:35 Export PDF Favorites Scan
  • The application value of virtual reality technology in the surgical treatment of coronary artery fistula and abnormal origin of coronary artery

    ObjectiveTo evaluate the application value of virtual reality (VR) technology in the surgical treatment of coronary artery fistula (CAF) and abnormal origin of coronary artery (AOOCA).MethodsFrom January 2014 to June 2018, with the assistance of virtual reality technology, 4 patients with CAF and 4 patients with AOOCA in the Department of Cardiac Surgery of our hospital underwent treatment method deciding and operation details planning. In the CAF patients, there was 1 male and 3 females and they were 8 years, 16 years, 62 years, and 65 years, respectively. In the AOOCA patients, there was 1 male and 3 females at age of 4-month, 2 years, 14 years, and 29 years, respectively.ResultsThe virtual heart models in all 8 patients were well matched with the real heart. The spatial structure information of CAF/AOOCA and surroundings can be intuitively and fully shown by virtual reality technology in all patients. All of the 4 CAF patients repaired coronary artery incision, including 2 patients with autologous pericardium patch and 2 patients with direct suture. Of the 4 AOOCA patients, 3 underwent coronary directly transplantation but 1 underwent Takeuchi surgery. And 2 had mitral valve plasty at the same time. All the operations were completed successfully, with good recovery and no serious complications. Among the 4 CAF patients, 3 had no residual fistula, and 1 had minor residual fistula. Coronary arteries were all unobstructed in 4 patients of AOOCA; moderate and severe mitral regurgitation in 2 patients were significantly reduced after surgery.ConclusionVR allows doctors to understand the spatial structure information of CAF/AOOCA and surroundings before the operation, and assists them to make accurate treatment decisions and develop detailed surgical plans before the operation, ensuring its safety. Its clinical application value is significant.

    Release date:2019-03-01 05:23 Export PDF Favorites Scan
  • Application and evaluation of modified pericardial oblique sinus approach in total anomalous pulmonary venous connection in neonates

    Objective To analyze the use of modified pericardial oblique sinus approach in surgical repair for total anomalous pulmonary venous connection in neonates. Methods Between May 2005 and December 2015, 67 consecutive neonates with supracardiac or infracardiac type total anomalous pulmonary venous connection who underwent surgical repair in our institute were included in this study. The patients are divided into three groups according to the different approaches including a sulcus approach group (6 patients), a superior approach group (14 patients), and a modified pericardial oblique sinus approach group (47 patients). There were 53 males and 14 females at median age of 12.5 (7.0, 20.5) d. Results The time of cardiopulmonary bypass [88 (80.0, 107.0) min vs. 135 (121.0, 157.0) min, P<0.05] and aortic cross clamping of the modified pericardial oblique sinus approach group was significantly shorter than that of the sulcus approach group [45 (39.0, 53.0) min vs. 80 (73.0, 85.0) min, P<0.05]. Perioperative mortality (2.1% vs. 28.6%, P<0.05) was significantly lower in the modified pericardial oblique sinus approach group than that in the superior approach group. The long-term mortality (4.3% vs. 60.0%, P<0.05) was significantly lower in the modified pericardial oblique sinus approach group than that in the sulcus approach group or the superior approach group . The rate of pulmonary venous stenosis was significantly lower in the modified pericardial oblique sinus approach group than that in the sulcus approach group (2.1% vs. 50.0%, P<0.05) or superior approach group (2.1% vs. 35.7%, P<0.05). Conclusions In surgical correction of neonatal supracardiac and infracardiac total anomalous pulmonary venous, compared with the traditional surgical approach, the modified pericardial oblique sinus pathway can provide excellent surgical space and has a good surgical prognosis.

    Release date:2019-09-18 03:45 Export PDF Favorites Scan
  • Analysis and evaluation of risk factors associated with poor prognoses of children with tetralogy of Fallot during perioperative period

    ObjectiveTo quest the risk factors of poor prognoses in children with tetralogy of Fallot (TOF) during perioperative period and evaluate its clinical application values.MethodsA retrospective analysis of the clinical data of 119 children who underwent one-stage correction of TOF in Guangdong Provincial People's Hospital from September 2016 to January 2019. The cohort includes 75 males and 44 females, with ages ranging from 3.2-137.1 (13.2±1.4) months and weights ranging from 4.6-21.0 (8.3±0.2) kg. Perioperative poor prognosis was defined as duration of mechanically assisted ventilation >48 h or secondary intubation, vasoactive-inotropic score (VIS) within 48 h >40, postoperative length of stay >14 d, and the occurrence of the major adverse events. Major adverse events were defined as early death, malignant arrhythmia, low cardiac output syndrome, non-fatal cardiac arrest, postoperative reintervention, diaphragm paralysis, and other clinical complications. Univariate and multivariate logistic analyses were used to analyze the correlation between risk factors and poor prognoses.ResultsThere was 1 perioperative death, and 9 with major adverse events. Variables selected by Least Absolute Shrinkage and Selection Operator (LASSO) included 2 preoperative variables (McGoon index, aortic root diameter index) and 4 intra-operative variables [left-right direction of bicuspid pulmonary valve, total length of right ventricular outflow tract (RVOT) incision index, pulmonary valve with commissurotomy, and minimum temperature in cardiopulmonary bypass (CPB)]. Univariate and multivariate logistic analyses were used to the above factors, respectively. The variables with statistical significance (P≤0.05) were McGoon index, aortic root diameter index, left-right direction of bicuspid pulmonary valve, and minimum temperature in CPB. A nomogram was established based on the above factors, and the results showed that the left-right direction of bicuspid pulmonary valve was more risky than the tricuspid pulmonary valve and the anterior-posterior direction of bicuspid pulmonary valve. The lower the McGoon index, the higher aortic root diameter, and the lower temperature in CPB, the higher risk of poor prognostic events in children with TOF.ConclusionThe left-right direction of the pulmonary bicuspid valve has a higher risk of poor prognosis than the tricuspid pulmonary valve and the anterior-posterior direction of bicuspid pulmonary valve. With the smaller McGoon index and the larger aortic root diameter, the risk of poor prognoses in children with TOF is higher. The temperature in CPB being lower than medium-low temperature obviously relates to the high incidence of poor prognostic events, which can be used as an auxiliary reference standard for decision-making in pediatric TOF surgery in the future.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content