west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "CHANG Xin" 5 results
  • Application of Hemoglobin-based Oxygen Carriers in Cardiac Surgery

    Hemoglobin-based oxygen carriers (HBOCs) is a kind of blood substitutes. It is a separated, ultra-purified, modified human or bovine hemoglobin in a balanced saline solution. After modification, it has longer half-time, less renal toxicity, and better delivery of O2 even at low temperature and pH. Its shelf life is long and it dose not require cross-matching. In the field of cardiac surgery, the use of HBOCs can reduce the amount of transfusion postoperatively, and can be used in cardiopulmonary bypass priming and myocardial protection.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
  • Protection Effect of Isolated Ischemic Heart by Polyethylene Glycolbovine Hemoglobin Solution

    Objective To investigate the effect of polyethylene glycolbovine hemoglobin (PEG-bHb), which was used as an oxygen carrier in cardioplegic solution, on the protection of isolated rat hearts. Methods The hearts of 32 male SD rats were harvested and transferred to Langendorff circuit. They were divided into 4 groups according to cardiocplegia: St.Thomas group (group A), 1∶2 PEG-bHb group (group B), 1∶4 PEG-bHb group (group C) and 1∶8 PEG-bHb group (group D). After 20min balance period, hearts were perfused with cold (4℃) cardioplegic solutions, and preserved at 30℃ for 60min, then reperfused. Levels of cardiac troponin I (cTn I) and adenosine triphosphate(ATP) contant in coronary effuent were detected, and ultrastructures of myocardium were observed. Results After reperfusion, cTn I contant of group A were higher (F=52.955,Plt;0.05) and ATP contant were lower (F=68.757,Plt;0.05) than those in group B, group C and group D. Myocardial water contant were lower in group B and group C(F=3.048,Plt;0.05). Conclusion PEG-bHb in cardioplegic solutions can provide better myocardial protection during ischemia.

    Release date:2016-08-30 06:09 Export PDF Favorites Scan
  • Short-term effectiveness of the first ray tri-plane osteotomy and other metatarsal basal osteotomy for hallux valgus with moderate and severe metatarsus adductus

    ObjectiveTo evaluate the short-term effectiveness of the first ray tri-plane osteotomy and other metatarsal basal osteotomy in treatment of hallux valgus with moderate and severe metatarsus adductus.MethodsBetween February 2012 and September 2016, 10 patients (12 feet) of hallux valgus with moderate and severe metatarsus adductus were admitted and treated with the first ray tri-plane osteotomy and other metatarsal basal osteotomy and lateral soft tissue release. There were 1 male (2 feet) and 9 females (10 feet) with an average age of 34.5 years (range, 21-55 years). The disease duration ranged from 3 to 10 years (mean, 5.8 years). The degree of metatarsal adductus was moderate in 4 feet and severe in 8 feet according to modified Sgarlato measurement method. Preoperative American Orthopaedic Foot and Ankle Society (AOFAS) score was 46.4±9.3. The metatarsus adductus angle (MAA) was (25.41±3.66)°, hallux valgus angle (HVA) was (41.42±9.67)°, and the first-second intermetatarsal angle (1-2IMA) was (10.72±2.26)°.ResultsAll incisions healed by first intention. All patients were followed up 18-24 months, with an average of 21.4 months. One patient (1 foot) had metastatic metatarsalgia after operation, but the symptoms disappeared after symptomatic treatment. X-ray re-examination showed that all osteotomies healed, and the healing time was 2.4-3.2 months, with an average of 2.8 months. At last follow-up, MAA was (8.42±0.71)°, HVA was (13.29±1.03)°, 1-2IMA was (4.41±0.48)°, and AOFAS score was 89.8±5.9. There were significant differences in clinical and radiographic indexes between pre- and post-operation (P<0.05).ConclusionThe first ray tri-plane osteotomy combined with other metatarsal basal osteotomy has a significant short-term effectiveness in the treatment of hallux valgus with moderate and severe metatarsus adductus.

    Release date:2020-02-18 09:10 Export PDF Favorites Scan
  • Comparison of bioabsorbable screw and metallic screw for Maisonneuve fracture

    ObjectiveTo compare the clinical and radiographic outcomes of bioabsorbable screw and metallic screw for Maisonneuve fracture.MethodsThe clinical data of 68 patients of Maisonneuve fracture treated with open reduction and internal fixation between October 2012 and October 2016 were retrospectively analyzed. Metallic screw fixation was used in 37 cases (group A) and absorbable screw fixation was used in 31 cases (group B). There was no significant difference in age, gender, weight, operated side, cause of injury, time from injury to operation, and complications between the two groups (P>0.05). At last follow-up, the tibiafibular clear space (TFCS), tibiafibular overlap (TFO), medial clear space (MCS), and syndesmotic malreduction rate were recorded. And the dorsiflexion and plantar-flexion range of motion, pain visual analogue scale (VAS) score, ankle and hind foot score of American Orthopaedic Foot and Ankle Society (AOFAS), and Olerud-Molander (OM) score were recorded.ResultsAll patients were followed up 25-43 months, with an average of 32.3 months. There was no significant difference in the operation time between the two groups (t=1.229, P=0.282). All the fractures healed, and there was no significant difference in fracture healing time between the two groups (t=1.367, P=0.413). At last follow-up, the syndesmotic malreduction rate of group A was 16.2% (6/37), showing no significant difference when compared with group B [6.2% (2/31)] (χ2=1.549, P=0.213). There were 3 complications in group A, 1 was superficial wound infection, 1 was local heterotopic ossification due to failure to remove the screws in time, 1 was local heterotopic ossification of the screws; and there were 2 complications in group B, 1 was rejection and 1 was local heterotopic ossification of the screws. There was no significant difference in the incidence of complications between the two groups (χ2=0.068, P=0.794). There was no significant difference in TFCS, MCS, TFO, ankle dorsiflexion and plantar-flexion range of motion, AOFAS score, OM score, and VAS score between the two groups at last follow-up (P>0.05).ConclusionCompared with metallic screw, absorbable screws provide adequate fixation and functional recovery with avoiding screw removal and lower syndesmotic malreduction.

    Release date:2020-04-29 03:03 Export PDF Favorites Scan
  • Effectiveness of tibialis posterior tendon transfer for foot drop secondary to peroneal nerve palsy

    ObjectiveTo investigate the effectiveness of tibialis posterior tendon transfer for foot drop secondary to peroneal nerve palsy.MethodsThe clinical data of 21 patients with unilateral foot drop secondary to peroneal nerve palsy between October 2009 and September 2016 was retrospectively analyzed. There were 12 males and 9 females with an average age of 32.1 years (range, 23-47 years). The causes of peroneal nerve injury were iatrogenic injury in 7 cases, tibiofibular fractures combined with compartment syndrome in 5 cases, nerve exploration surgery after stab or cut injury in 3 cases, direct violence in 4 cases, and the fibular head fracture in 2 cases. The average time from injury to operation was 5.6 years (range, 2-8 years). There was 1 case of hallux valgus and 5 cases of toe flexion contracture. The American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot scores, Foot and Ankle Ability Measure (FAAM) scores, range of motion (ROM), and dorsiflexion strength of ankle joint were used to evaluated the ankle function. Radiographic evaluation for the changes of postoperative foot alignment included Meary angle, calcaneal pitch angle, and hindfoot alignment angle.ResultsAll incisions healed by first intention. All patients were followed up 18-42 months (mean, 30.2 months). The dorsiflexion strength of ankle joint recovered from grade 0 to grade 3-4 after operation. There was no patient with a postoperative flat foot deformity and claw toe during follow-up. There was no significant difference in Meary angle, calcaneal pitch angle, and hindfoot alignment angle between pre- and post-operation (P>0.05). The AOFAS score, FAAM score, and ROM of dorsiflexion significantly improved at last follow-up when compared with preoperative values (P<0.05); while there was no significant difference in ROM of plantar-flexion between pre- and post-operation (t=4.239, P=0.158). There were significant differences in AOFAS score, FAAM score, and ROM of dorsiflexion between affected and healthy sides (P<0.05); but no significant difference in ROM of plantar-flexion was found (t=2.319, P=0.538).ConclusionTibialis posterior tendon transfer is an effective surgical option for foot drop secondary to peroneal nerve palsy. And no postoperative flat foot deformity occurred at short-term follow-up.

    Release date:2020-06-15 02:43 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content