west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "CHENXu" 4 results
  • Expression of Tumor Necrosis Factor-α in Prostate Cancer and Its Clinical Significance

    ObjectiveTo investigate the expression of tumor necrosis factor-α (TNF-α) in prostate cancer tissue and explore its relations with tumor angiogenesis. MethodsThe expression of TNF-α and CD105 were detected with two-step immunohistochemical staining technique in 20 cases of benign prostatic hyperplasia and 50 cases of prostate cancer between January 2010 and January 2012, and microvessel density (MVD) marked with CD105 was also measured. ResultsThe expressions of TNF-α and CD105 were higher in prostate cancer (41.72±8.67, 20.15±2.67) than those in benign prostatic hyperplasia (21.01±3.85, 4.34±1.67) (t'=13.990, P<0.001; t'=29.771, P<0.001). TNF-α and MVD were not correlated with age and size of tumor, but were positively correlated with tumor differentiation degree (rs=0.847, P<0.001; rs=0.776, P<0.001) and negatively correlated with clinical grades (rs=-0.769, P<0.001; rs=-0.842, P<0.001). ConclusionThe result indicates that over expression of TNF-α exists in prostate cancer. It may play an important role in the anginogenesis and carcinogenesis of prostate cancer.

    Release date: Export PDF Favorites Scan
  • CLINICAL OBSERVATION OF Othofix PERTROCHANTERIC FIXATOR FOR FIXATION OF INTERTROCHANTERIC FRACTURE

    ObjectiveTo evaluate the effectiveness of Othofix pertrochanteric fixator for fixation of intertrochanteric fracture. MethodA retrospective analysis was made on the clinical data from 36 cases of intertrochanteric fracture treated with Othofix pertrochanteric fixator (OPF group) and 47 cases treated with Gamma nail (Gamma group) between October 2012 and March 2015. There was no significant difference in gender, age, cause of injury, side, AO fracture classification, combined medical disease, and injury to operation time between 2 groups (P>0.05) . The operation time, intraoperative blood loss, hospitalization time, fracture union time, and complication rate were recorded and compared between 2 groups. Hip function was evaluated with Sanders post-trauma criteria. ResultsThe operation time, intraoperative blood loss, and hospitalization time of the OPF group were significantly less than those of the Gamma group (P<0.05) . All the cases were followed up 6-12 months (mean, 8.8 months) in 2 groups. Healing of incision by first intention was obtained. Bone union was achieved in 2 groups, and the fracture union time of the OPF group was significantly shorter than that of the Gamma group (t=14.780, P=0.000) . There was no deep wound or pin track infection in 2 groups. Superficial skin reactions developed around the screw and the pins in 14 cases (38.9%) of the OPF group, but no incision infection in the Gamma group, showing significant difference (χ2=22.010, P=0.001) . Mild varus of the hip and pin cutting-out occurred in 3 cases (8.3%) and 2 cases (5.6%) of the OPF group, and in 4 cases (8.5%) and 3 cases (6.4%) of Gamma group, showing no significant difference (χ2=0.001, P=0.960; χ2=0.025, P=0.830) . According to Sanders post-trauma criteria, the results were excellent in 16 cases, good in 15 cases, fair in 3 cases, and poor in 2 cases, with an excellent and good rate of 86.1% in the OPF group; the results were excellent in 22 cases, good in 20 cases, fair in 4 cases, and poor in 1 case, with an excellent and good rate of 89.4% in the Gamma group; and there was no significant difference (χ2=0.200, P=0.610) . ConclusionsThe Othofix pertrochanteric fixator has good effectiveness in the treatment of intertrochanteric fracture, which has the advantages of simple operation, less operation time, little bleeding, and early functional recovery.

    Release date: Export PDF Favorites Scan
  • DIGITAL DESIGN OF STANDARD PARTS DATABASE FOR PROXIMAL TIBIA FRACTURES TREATED WITH PLATING VIA THREE-DIMENSIONAL PRINTING

    ObjectiveTo explore the method and feasibility of digital internal fixation for proximal tibia fractures using standard parts database and three-dimensional (3D) printing technology. MethodsTen adult lower extremity specimens were selected to take continuously thin-layer scanning. After Dicom image was imported into the Mimics software, the model of Schatzker Ⅱ-VI types proximal tibia fracture was established, 2 cases each type. The virtual internal fixation was performed with plate and screw from standard parts database. The pilot hole of the navigation module design was printed by 3D printing technique. The plate and screw were inserted by the navigation module. X-ray film and CT were taken postoperatively to observe the position. Thirty patients with proximal tibia fracture underwent digital internal fixation using standard parts database and 3D printing technology (study group), and another 30 patients underwent traditional open reduction and internal fixation (control group). There was no significant difference in sex, age, side, causes, fracture classification, associated injury, and course of disease between 2 groups (P>0.05). The preparative time, incision length, fracture healing time, operation time, and intraoperative blood loss were recorded. Follow up of imaging evaluation, clinical efficacy was evaluated by MacNab criteria. ResultsThe navigation models were designed to fit the bony structure of proximal tibia and to guide implant insertion. The parameters of orientation, length, diameter, and angle were consistent with the preoperative plan. No statistically significant difference was found in the preparative times of pre-operation between 2 groups (t=1.393, P=0.169). The incision length, wound healing time, blood loss, operation time, and the cost of treatment in study group were significantly less than those in control group (P<0.05). All patients were followed up 12-16 months (mean, 13.5 months). The fracture healing time of study group was significantly shorter than that of control group (t=4.070, P=0.000). At 12 months postoperatively, there was no significant difference in the efficacy based on MacNab criteria between 2 groups (U=377.000, P=0.238). ConclusionDigital internal fixation for proximal tibia fractures using standard parts database and 3D printing technology has the advantages of short process, less blood loss, high safety and rapid fracture healing.

    Release date: Export PDF Favorites Scan
  • Clinical application of accurate placement of lumbar pedicle screws using three-dimensional printing navigational templates under Quadrant system

    Objective To explore the feasibility and the effectiveness of the accurate placement of lumbar pedicle screws using three-dimensional (3D) printing navigational templates in Quadrant minimally invasive system. Methods The L1-5 spines of 12 adult cadavers were scanned using CT. The 3D models of the lumbar spines were established. The screw trajectory was designed to pass through the central axis of the pedicle by using Mimics software. The navigational template was designed and 3D-printed according to the bony surface where the soft tissues could be removed. The placed screws were scanned using CT to create the 3D model again after operation. The 3D models of the designed trajectory and the placed screws were registered to evaluate the placed screws coincidence rate. Between November 2014 and November 2015, 31 patients with lumbar instability accepted surgery assisted with 3D-printing navigation module under Quadrant minimally invasive system. There were 14 males and 17 females, aged from 42 to 60 years, with an average of 45.2 years. The disease duration was 6-13 months (mean, 8.8 months). Single segment was involved in 15 cases, two segments in 13 cases, and three segments in 3 cases. Preoperative visual analogue scale (VAS) was 7.59±1.04; Oswestry disability index (ODI) was 76.21±5.82; and the Japanese Orthopaedic Association (JOA) score was 9.21±1.64. Results A total of 120 screws were placed in 12 cadavers specimens. The coincidence rate of placed screw was 100%. A total of 162 screws were implanted in 31 patients. The operation time was 65-147 minutes (mean, 102.23 minutes); the intraoperative blood loss was 50-116 mL (mean, 78.20 mL); and the intraoperative radiation exposure time was 8-54 seconds (mean, 42 seconds). At 3-7 days after operation, CT showed that the coincidence rate of the placed screws was 98.15% (159/162). At 4 weeks after operation, VAS, ODI, and JOA score were 2.24±0.80, 29.17±2.50, and 23.43±1.14 respectively, showing significant differences when compared with preoperative ones (t=14.842,P=0.006;t=36.927,P=0.002;t=–36.031,P=0.001). Thirty-one patients were followed up 8-24 months (mean, 18.7 months). All incision healed by first intention, and no complication occurred. During the follow-up, X-ray film and CT showed that pedicle screw was accurately placed without loosening or breakage, and with good fusion of intervertebral bone graft. Conclusion 3D-printing navigational templates in Quadrant minimally invasive system can help lumbar surgery gain minimal invasion, less radiation, and accurate placement.

    Release date:2017-03-13 01:37 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content