Objective To report the experiences of cardiac valve operation in children. Methods Cardiac valve operations were performed in 87 children who were 58 male and 19 female between age of 4 to 14 years (mean 10.2 years). Of the 87 patients, 36 underwent mitral valve replacement, 13 aortic valve replacement, 6 mitral and aortic valve replacement, 13 aortic valvuloplasty, and 19 mitral valvuloplasty. Associated cardiac lesions were simultaneously managed. Results Postoperative complications included low car...
Objective To explore the affecting factors on sinus rhythm maintenance after electric cardioversion for patients with atrial fibrillation (Af) after cardiac valve replacement. Methods One hundred fifty two valvular disease patients with Af after cardiac valve replacement were randomized to 2 groups: Amiodarone group and control group (without anti arrhythmic drugs) after cardioversion. Af recurrence was observed during one year follow up. Results (1) No significant difference of Af recurrence betwe...
Objective To investigate the perioperative changes of serum brain natriuretic peptide (BNP) concentrations in patients undergoing cardiac valve replacement. Methods There were 20 patients admitted to the study, the serum BNP concentrations were measured before cardiac surgery, 24 hours, 7days, 14 days, and 30 days after operation. The preoperative NYHA cardiac function and the left ventricular ejection fraction(LVEF) were measured by echocardiogram. Results The preoperative BNP level was the baseline, it elevated markedly and acutely to a peak value 24 hours after operation ( P =0.003), then the BNP decreased 7 days later, but was still higher than the concentration before operation ( P =0.015), 14 days later it reached to the concentration before operation, 30 days later it was mild lower than preoperative BNP level, but there was no significant difference. There was a positive correlation between NYHA and BNP ( r =0.69, P lt;0.05), but no correlation between LVEF and BNP( r =0.29, P gt;0 05). Conclusion The preoperative serum BNP concentration can reflect the preoperative cardiac function in patients undergoing cardiac valve replacement, the high BNP level indicates the poor cardiac function. The BNP sharply elevated in the early time after operation, then gradually decreased in the late phase postoperation.
Hemorrhage and thromboembolism are the most important long-term complications of anticoagulation therapy after mechanical heart valve replacement. The anticoagulation therapy intensity should be lowered in order to decrease the hemorrhagic complication. In recent years, the chief progresses of anticoagulation therapy are the using of International Normalized Ratio (INR) in anticoagulation therapy monitoring and the low intensity anticoagulation therapy. The proper anticoagulation intensities at home are INR 1.5-2.0 and prothrombin time ratio (PTR) 1.3-1.5. It is beneficial to adopt this low intensity anticoagulation therapy for decreasing the death rate from hemorrhage, protecting pregnant women and new borns from hemorrhage and malformation, and improving the life qualities of the patients.
Abstract: Objective To investigate the in vivo effective orifice area (EOA) and whether prosthesispatient mismatch (PPM) is going to happen after 19mm St.Jude Regent valves replacement were performed. Methods Twentythree patients with valvular heart diseases were divided into 2 groups according to aortic annular diameter. 19mm St. Jude Regent valves were replaced in aortic valve place (Regent valve group), and 21mm other doubleleaflet mechanical valves were replaced in aortic place (other valves group). All of the operations were accomplished under cardiopulmonary bypass in West China Hospital. All of the patients were followed up in 3 to 6 months after their surgery processes. Color Doppler echocardiography was used to measure the hemodynamic parameters in their followup. Then left ventricular mass (LV mass), EOA and effective orifice area index (EOAI) etc. were calculated and compared by using SPSS 12.0. Results No cardiac episodes were detected during the perioperative period and 36 months after operation. LVmass reduced in 36 months after operation in both groups. No statistical significance of EOA, EOAI and LVmass reduction were detected between the two groups. Conclusions (1)The EOA and in vivo hemodynamic effects of 19mm Regent valve are similar to 21mm other double leaflet mechanical valve. (2)It is safe to use 19mm Regent valve in those patients whose aortic annular diameter are small and need double valve replacement. Using 19mm Regent valve will not cause short time cardiac episodes and PPM. (3)More further works should be done to make sure what is the standard of PPM in Chinese people, such as enlarging the patients number and prolonging the followup time. (4) Further clinical and followup works should be done to make St.Jude Regent valve’s feature out.
Objective To investigate the effects of tight blood glucose control on the shortterm prognosis of the patients after heart valve replacement, in order to improve treatment effectiveness and lower postoperative complications. Methods A total of 240 patients including 150 males and 90 females underwent mitral valve replacement or mitral and aortic valve replacement were enrolled in this study from January 2007 to December 2008 at the cardiac surgery department of Renmin hospital of Wuhan university. The age of these patients ranged from 19 to 65 years old with an average age of 53.33 years. According to insulin administration time and blood glucose control level, they were randomly separated into two groups. In the experimental group, there were 121 patients who received continuous insulin infusion to maintain postoperative glucose level between 4.4 and 6.1 mmol/L, while 119 patients in the control group received insulin infusion when their glucose level went higher than 11.1 mmol/L to control the level between 6.1 and 11.1 mmol/L. Then the postoperative wound infection, malignant arrhythmia rate, the assisted ventilation time, intensive care unit(ICU) stay time and count of neutrophils were compared and analyzed. Results There was no hospitalized death in both groups. The rate of wound infection(3.31% vs.10.08%, χ2=4.430,P=0.035), the assisted ventilation time(9.02±2.73 h vs. 10.01±3.58 h, t=2.280,P=0.024), time for count of leukocytes to decrease to the normal level(11.04±3.16 d vs. 12.05±3.76 d, t=2.168,P=0.031), average hospitalization time(13.49±3.81 d vs. 14.51±4.02 d,t=2.017,P=0.045), and count of neutrophils on the third day(0.82±0.04 vs. 0.84±0.05, t=2.644,P=0.009) in the experimental group were significantly lower or shorter than those in the control group. But there was no significant difference between both groups in ICU stay time and the rate of malignant arrhythmia. Conclusion Tight blood glucose control can lower the rate of postoperative wound infection, shorten the assisted ventilation time and hospitalization time, and reduce the usage of antibiotics in patients after heart valve replacement. Accordingly, it can enhance the curative effect, reduce overall medical expenses, and improve prognosis.
Abstract:Since 1978 the definition of prosthesis-patient mismatch(PPM) was first introduced by Rahimtoola, it has attracted the attention of foreign researchers. The PPM phenomenon is concerned to be an important factor which will affect patients' survival rate and quality of life. Till now, a lot of effort should still be put on this problem. But unfortunately, this problem is still being neglected in our country. This paper is a review of PPM from it's many aspects, such as definition, current research status, prevention, and it's research prospect. We hope this paper will intensify the clinicians' knowledge on PPM.
Objective To compare the efficacy of 6-epsilon-aminocaproic acid (EACA) with aprotinin on reducing postoperative bleeding in cardiac valve replacement procedures, and to investigate its influence on the possible thromboembolism and the renal function. Methods Seventy-nine patients who underwent cardiac valve replacement were randomly divided into two groups: EACA group (n = 39) and aprotinin group (n = 40), which were given EACA and aprotinin separately in operations. The volumes of drainage to body surface area (BSA), blood transfusion were recorded during 24 h after operations. The concentrations of serum D-dimer and α2-antiplasmin (a2- AP) were measured before, during operation and at 72h post-operatively. The serum creatinine levels before operation and at the 72 h after operation were also measured. Results The volume ratio of drainage to BSA in EACA group was significantly higher than that in the aprotinin group at 24 h after operation (P = 0. 019). However, there was no significant difference in the volumes of blood transfusion between two groups (P〉0. 05). Also no statistical difference in the concentrations of D-dimer and a2-AP were found between two groups whether preoperatively or at 72h post-operatively (P= 0. 960,0. 485), D-dimer and a2-AP of the aprotinin group were higher than those in the EACA group after aortic off-clamping (P = 0. 001,0. 000). There was no statistically difference of △CrCl72 in both groups (P〉0. 05). No patient with thrombosis or thromboembolism was detected in two groups.Conclusion Although the efficacy of EACA in reducing postoperative bleeding in cardiac valve replacement can not compare favorably with that of aprotinin, the blood transfusion volume would not increase when EACA is used introoperatively. Proper usage of EACA will not cause thrombosis and renal damage.
ObjectiveTo observes the postoperative transformation of subjective and objective sleep quality and related influencing factors in patients with rheumatic valvular heart disease (RVHD) who were found with central sleep apnea (CSA) after cardiac valve replacement.MethodsA total of 262 patients undergoing cardiac valve replacement were screened for CSA by overnight polysomnography and 21 patients with CSA were enrolled and followed up successfully in the 3th, 6th and 12th month of postoperation from April 2010 to January 2013. The Pittsburgh Sleep Quality Index, Epworth Sleepiness, polysomnography and cardiac function were evaluated in preoperation and postoperation (in the 3th, 6th and 12th month).ResultsNew York Heart Association class [preoperation and postoperation: (3.7±0.5), (2.3±0.6), (1.7±0.6), (1.6±0.7), F=81.124, P<0.05] continuously decreased, left ventricular ejection fraction [preoperation and postoperation: (58.5±6.8)%, (60.0±7.4)%, (60.9±5.6)%, (64.4±4.0)%, F=7.182, P<0.05] steadily increased, six-minute walk distance [preoperation and postoperation: (271.5±76.6), (422.1±71.9), (445.1±56.2), (454.5± 63.5) m, F=67.134, P<0.05] constantly increased. During postoperative follow-up, sleep apnea-hypopnea index [preoperation and postoperation: (26.2±13.4), (12.0±11.5), (8.6±7.5), (7.4±5.5)/h, F=20.548, P<0.05, central sleep apnea index [preoperation and postoperation: (19.6±10.3), (0.5±1.5), (0.3±1.3), (0.2±0.7)/h, F=72.926, P<0.05] and oxygen desaturation index [preoperation and postoperation: (20.1±16.6), (10.8±9.5), (8.5±7.2), (6.1±5.1)/h, F=9.646, P<0.05] sustained improved. Aroual index [preoperation and postoperation: (23.1±12.1), (2.7±3.8), (3.5±4.8), (2.2±2.1)/h, F=58.370, P<0.05] presented overall downward trend. Pittsburgh Sleep Quality Index scale [preoperation and postoperation: (11.1±3.2), (8.2±3.3), (6.0±3.8), (4.4±2.5), F=27.670, P<0.05] were constantly improved. Epworth Sleepiness scale [preoperation and postoperation: (13.3±5.7), (6.9±4.5), (8.2±4.8), (6.1±3.7), F=15.994, P<0.05] showed overall reduction.ConclusionThe sleep quality of patients with RVHD and CSA is improved after cardiac valve replacement, of which the trend is in keep with postoperative recovery of cardiac function.
Objective To investigate the effect of early postoperative enteral nutrition support on the balance of free amino acid spectrum in plasma for patients with cardiac valve replacement during perioperative period. Methods (Forty-seven) patients undergoing cardiac valve replacement were divided into two groups randomly, the routine diet group and the Nutrison Fibre group. The levels of free amino acids in plasma were measured with pre-column derivatization of high-performance liquid chromatography. Results During perioperative period most free amino acids in plasma decreased significantly in the routine diet group (Plt;0.05). Despite some free amino acids in plasma decreased significantly in the Nutrison Fibre group(Plt;0.05), all free amino acids in plasma returned to (Pgt;05) or were higher than the preoperative levels in the postoperative sixth day (Plt;0.05). At the same postoperative points, most free amino acids in plasma in the Nutrison Fibre group were higher than that of the routine diet group (Plt;0.05). Conclusions The levels of free amino acids in plasma decrease significantly in patients with cardiac valve replacement after operation. Early postoperative Nutrison Fibre enteral nutrition support is helpful for keeping the balance of free amino acids in plasma for patients with cardiac valve replacement.