Objective To evaluate the methodological quality and reporting quality of clinical guidelines and consensus on central venous catheters. Methods The PubMed, EMbase, Web of Science, CBM, WanFang Data, CNKI databases and Guidelines International Network, National Institute for Health and Clinical Excellence, National Guideline Clearinghouse, Medive.cn websites were searched to collect clinical guidelines and consensus related to central venous catheters. The retrieval time was from the establishment of the database to October 2022. Two researchers independently screened the literature, extracted data and used evaluation tools AGREE Ⅱ and RIGHT to evaluate the quality of the included studies. Results A total of 34 central venous catheter guidelines and consensus were included. The average score for each field of AGREE II was 53.73% for scope and purpose, 39.26% for participants, 39.57% for rigor, 46.76% for clarity, 30.23% for application and 49.18% for editorial independence. Items 1a, 1b, 3, and 4 (100.00%) had the highest reporting rate in the RIGHT evaluation items, followed by items 19a (97.05%), 2/19b (94.11%), 20 (91.17%), 7b/11a (88.23%), and 7a (85.29%). The reporting rate of the remaining items was below 60%. Subgroup analysis results showed that the average score and RIGHT score of the guidance class in the four fields of AGREE Ⅱ (rigor, clarity, application and editorial independence) were higher than those of the consensus class. Guidelines and consensus formulated based on evidence-based medicine methods were higher than those formulated based on expert opinions or reviews in the three fields of AGREE II (rigor, application and editorial independence). The average scores of foreign guidelines and consensus in 6 fields and RIGHT scores of AGREE Ⅱ were higher than those of domestic guidelines and consensus. Conclusion The AGREE Ⅱ of 6 fields average score and RIGHT score in foreign guidelines are higher than those in domestic guidelines.
ObjectiveTo investigate the influence of misplaced subclavian vein (SCV) catheter into the ipsilateral internal jugular vein (IJV) on transpulmonary thermodilution (TPTD) measurements and explore the possible mechanisms preliminarily.MethodsIn this prospective study, 408 patients in whom an SCV catheterization was indicated for TPTD monitoring were enrolled. A first set of TPTD measurements was collected at baseline in all patients (group 1, SCV catheters were correctly placed; group 2, SCV catheters were misplaced into the ipsilateral IJV). The parameters included mean transit time (MTt), downslope time (DSt), cardiac index (CI), global end-diastolic volume index (GEDVI) and extra-vascular lung water index (EVLWI). A second set of TPTD measurements was performed only in those with catheter misplacement immediately after the misplaced SCV catheters being corrected (Group 3). The differences in MTt, DSt, GEDVI and EVLWI between group 2 and 3 were recorded as ΔMTt, ΔDSt, ΔGEDVI and ΔEVLWI, respectively.ResultsGEDVI and EVLWI were significantly higher (all P<0.001) in group 2 than those in group 1, while CI was not significantly different (P>0.05) between these two groups. Multivariate logistic regression identified PaO2/FiO2 [adjusted odds ratio (OR) 1.492/10 mm Hg; 95% confidence interval (CI), 1.180 - 1.884; P<0.001], GEDVI (OR=1.307/10 mL/m2, 95% CI 1.131 - 1.511; P<0.001) and EVLWI (OR=3.05; 95%CI 1.593 - 5.840; P<0.001) as the 3 independent factors associated with the misplacement of SCV catheter into the ipsilateral IJV. In group 2, GEDVI [(1041±122)mL/m2 vs. (790±102)mL/m2, P<0.001], EVLWI [(20.3±4.0)mL/kg vs. (10.3±2.3)mL/kg, P<0.001], CI [(3.6±1.2)L·min–1·m–2 vs. (2.9±1.0)L·min–1·m–2, P<0.001], MTt [(38.2±13.3)s vs. (30.8±9.4)s, P<0.001] and DSt [(18.9±7.2)s vs. (13.2±4.9)s, P<0.001)] were significantly higher than those in Group 3. Multiple regression analysis demonstrated that ΔEVLWI (R2=0.86, P<0.001) was negatively correlated with ΔMTt (coefficient±SE, –0.52±0.12; P<0.001) and positively correlated with ΔDSt (coefficient±SE, 1.45±0.17; P<0.001).ConclusionsDuring TPTD measurements, indicator injection through an SCV catheter misplaced into the ipsilateral IJV results in an overestimation of CI, GEDVI and EVLWI. The increase in DSt might be a key factor in explaining the overestimation of EVLWI in patients with misplaced SCV catheters. Given that the accurate measurements of GEDVI and EVLWI are of utmost importance for guiding resuscitation and decision-making regarding fluids administration, immediate repositioning is required if a misplacement is suspected and confirmed by the chest X-ray.
ObjectiveTo explore the influence of three central venous catheter biomedical materials (polyurethane, silicone, and polyvinyl chloride) on the proliferation, apoptosis, and cell cycle of Xuanwei Lung Cancer-05 (XWLC-05) cells so as to provide the basis for clinical choice of central venous catheter. MethodsXWLC-05 cells were cultured and subcultured, and the cells at passage 3 were cultured with polyurethane, silicone, and polyvinyl chloride (1.0 cm × 1.0 cm in size), and only cells served as a control. At 24, 48, and 72 hours after cultured, MTT assay was used to detect the cellular proliferation and flow cytometry to detect the cell cycle and apoptosis. At 72 hours after cultured, inverted microscope was used to observe the cell growth. ResultsInverted microscope showed the cells grew well in control group, polyurethane group, and silicone group. In polyvinyl chloride group, the cells decreased, necrosed, and dissolved; residual adherent cells had morphologic deformity and decreased transmittance. At 24 and 48 hours, no significant difference in proliferation, apoptosis, and cell cycle was found among 4 groups (P gt; 0.05). At 72 hours, the proliferations of XWLC-05 cells in three material groups were significantly inhibited when compared with control group (P lt; 0.05), and the cells in polyvinyl chloride group had more significant proliferation inhibition than polyurethane group and silicone group (P lt; 0.05), but there was no signifcant difference in proliferation inhibition between polyurethane group and silicone group (P gt; 0.05). Compared with the control group, three material groups had significant impact on the rate of apoptosis and cell cycle: polyvinyl chloride group was the most remarkable, followed by silicone group, polyurethane group was minimum (P lt; 0.05). ConclusionPolyvinyl chloride can significantly impact the proliferation, apoptosis, and cell cycle of XWLC-05 cells; polyurethane has better biocompatibility than polyvinyl chloride and silicone
ObjectiveTo investigate the effect of suprapubic catheterization(SPC) by using central venous catheter (CVC) on the perioperative complications in middle and low rectal cancer surgery. MethodsThe clinical data of 141 patients with middle and low rectal cancer underwent operation in Shengjing Hospital of China Medical University from April 2012 to January 2015 were collected. There were 65 patients performed SPC by using CVC, 76 patients performed routine transurethral catheterization(TUC). The incidences of bacteriuria and urinary retention, recatheterization rate, duration of catheterization, and catheter-related pain were analyzed and compared between these two groups. Results①Compared with the TUC, the SPC by using CVC could significantly reduce the incidence of bacteriuria(P=0.002), espe-cially in female(P=0.006), ≥60 years old(P=0.001), low rectal cancer(P=0.003), open surgery(P=0.018), Miles(P=0.016), and Dixon(P=0.032).②There was no significant difference in the incidence of urinary retention(P=0.464) between the SPC by using CVC and the TUC.③Compared with the TUC, the SPC by using CVC could significantly reduce the inci-dence of recatheterization rate(P=0.001), especially in the patients with male(P=0.016), ≥60 years old(P=0.008), low rectal cancer(P=0.019), laparoscopic surgery(P=0.013), and Miles(P=0.037).④Compared with the TUC, the point of catheter-related pain was significantly lower in the SPC by using CVC(P=0.001), no matter males(P=0.005) or females(P=0.010), aged 60 years and older(P=0.023) or younger(P=0.034), middle rectal cancer(P=0.017) or low rectal cancer(P=0.046), open surgery(P=0.033) or laparoscopic surgery(P=0.021), Dixon(P=0.019) or Miles(P=0.035).⑤The duration of catheterization was similar between the SPC by using CVC and the TUC(P=0.597). ConclusionSPC by using CVC is a safer, more effective and more acceptable method of bladder drainage in middle and low rectal cancer surgery as compared with routine TUC.
Objective To study the catheter-related infection (CRI) in cancer patients treated with central venous catheterization. Methods A prospective study with 196 cancer patients was conducted to analyze the types of catheter-related infection and pathogen, as well as the relationship between CRI and the following factors: insert location, gender, age, remained time, or bone marrow suppression. Results Of the total 196 cases, 16 cases were diagnosed as CRI and the CRI rate was 8.2%. The types of CRI were five cases of pathogen colonization, four cases of insert location infection and seven cases of catheter-related bloodstream infection. Of the total 244 specimens, 20 were positive including 7 pathogenic bacteria in either Gram positive or Gram negative types, the dominating pathogens were staphylococcus aureus, staphylococcus epidermidis, acinetobacter baumannii and klebsiella pneumoniae. CRI was related to both insert location and age which were both the independent risk factors. Conclusion The concept of prevention should be set up, and the comprehensive measures should be taken to reduce CRI, such as choosing an appropriate insert location and complying with a strict catheter insert standard.
Objective To investigate the risk factors of central line-associated bloodstream infection (CLABSI) and provide clinical guidance for reducing the incidence of CLABSI. Methods The clinical data of patients with central venous catheter catheterization in Sichuan Provincial People’s Hospital between January 2018 and December 2021 were retrospectively collected. According to whether CLABSI occurred, the patients were divided into CLABSI group and non-CLABSI group. The data of patients were analyzed and the risk factors of CLABIS were discussed. Results A total of 43 987 patients were included. Among them, there were 63 cases in the CLABSI group and 43924 cases in the non-CLABSI group. The incidence of CLABSI was 0.18/1 000 catheter days. Multivariate logistic regression analysis showed that admission to intensive care unit (ICU) [odds ratio (OR)=74.054, 95% confidence interval (CI) (22.661, 242.005), P<0.001], hemodialysis [OR=4.531, 95%CI (1.899, 10.809), P=0.001] and indwelling catheter days [OR=1.017, 95%CI (1.005, 1.029), P=0.005] were independent risk factors for CLABSI. A total of 63 strains of pathogenic bacteria were isolated from the 63 patients with CLABSI. Among them, 28 strains of Gram-positive bacteria, 25 strains of Gram-negative bacteria and 10 strains of Candida. Conclusions Admission to ICU, hemodialysis and long-term indwelling catheter are independent risk factors for CLABSI. The prevention and control measures of CLABSI should be strictly implemented for such patients to reduce the risk of infection.
ObjectiveTo explore the risk factors for central venous catheter (CVC)-related infections and its Countermeasures, as CVC is an important vascular access for blood purification and is widely used in clinical applications, but catheter-related infection is one of the common severe complications. MethodsWe retrospectively analyzed the clinical data of 725 patients with complicated infections of indwelling center venous double lumen catheter treated between January 2009 and December 2012. ResultsAmong all 725 cases, 15 had catheter-related infection. There were one case of subcutaneous tunnel infection (staphylococcus aureus by the secretion culture, negative for blood culture), and 14 cases of positive blood culture including 9 staphylococcus aureus cases, 3 escherichia coli cases, 1 colorless bacillus case and 1 stenotrophomonas maltophilia case. Eight cases were cured by antibiotic therapy while antibiotics were invalid in the other 7 cases resulting in tube withdrawing. ConclusionThe central venous catheter-related infections are related to medical service ability, catheter indwelling position, indwelling time, hemodialysis adequacy, patients' general condition and personal hygiene. Taking relative measures in view of each factor is the key to prevent infections.
Objective To explore the risk factors of catheter-associated bloodstream infections ( CRBSI) in intensive care unit ( ICU) of primary hospital. Methods A total of 623 patients with central venous catheters were recruited in the study. 60 of themsuffered fromCRBSI served as an observation group and other 563 cases without CRBSI served as control. Univariate analysis was used to scan possible risk factors. Then logistic regression analysis was used to exclude the confounding factors. Results The overall incidence rate of CRBSI was 9. 63% ( 60 /623) . There were significant differences in APACHE score, type of catheter, location of catheter, duration of central venous catheter, intravenous nutrition, use of steroid, times of intubation, urgent intubations, nutritional status, diabetes, and MODS between the two groups. Logistic regression analysis revealed that higher APACHE score, double-lumen catheter, femoral vein catheter, catheter indwelling more than two weeks, intravenous nutrition, intubation more than 2 times, and emergency intubation were risk factors of CRBSI. Conclusions Higher APACHE score, double-lumen catheter, femoral vein catheter, catheter indwelling more than two weeks, intravenous nutrition, intubation more than 2 times, and emergency intubation were major risk factors of CRBSI in ICU of primary hospital.
ObjectiveTo evaluate the clinical efficacy of central venous catheter closed drainage of pleural cavity combined with negative pressure suction in the treatment of spontaneous pneumothorax. MethodsThe randomized controlled trials(RCTs) on central venous catheter closed drainage of pleural cavity combined with negative pressure suction in the treatment of spontaneous pneumothorax were searched in PubMed, OVID, CNKI, Wangfang database, Super Star Digital Library, CMB, Baidu and Google search engines. The searching time was from the time of building database to September 15, 2014. Two searchers selected studies based on the included criteria strictly. The quality of RCTs was appraised by the criteria of Cochrane Collaboration. RevMan5.3 software was used for data analysis and management. ResultsA total of 18 RCTs including 1 549 patients were identified. There were no statistical differences in time of lung recruitment (SMD=0.01 and 95%CI -0.23 to 0.25, P=0.95), time of hospital stay (SMD=-0.42, 95%CI -1.81 to 0.97, P=0.55), curative resection rate (RR=1.04 and 95%CI 1.00 to 1.08, P=0.07) between the two groups. The rate of complications in the central venous catheter group was less than that in the conventional pleural cavity closed drainage group with a statistical difference (RR=0.31, 95%CI 0.23 to 0.43, P<0.000 01). ConclusionThe treatment of central venous catheter closed drainage of pleural cavity combined with negative pressure suction for spontaneous pneumothorax is a simple and safe operation. However, the quality of studies included is not high and some sample size is small. RCTs with large sample of high quality are still needed for further confirmation.
Objective To evaluate the flushing effects of normal saline (NS) and heparin saline (HPS) after central venous catheterization. Methods We searched PubMed, EMbase, The Cochrane Library (Issue 12, 2015), CBM, CNKI, VIP and WanFang Data to collect randomized controlled trials (RCTs) on the flushing effects of NS versus HPS after central venous catheterization from inception to December 2015. Two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies. Then RevMan 5.3 software was used for meta-analysis. Results A total of 12 RCTs involving 2 092 patients were included. The results of meta-analysis showed that no significant differences were found between the two groups in occlusion rate (OR=1.58, 95%CI 0.79 to 3.14,P=0.19) and the catheter days (OR=–7.24, 95%CI –22.90 to 8.41,P=0.36), while the HPS group had more advantage than the NS group in decreasing the incidence of phlebitis (OR=2.57, 95%CI 1.52 to 4.34,P=0.000 4). Subgroup analysis revealed that HPS provided more superiority over NS in lessening the occlusion rate (OR=1.85, 95%CI 1.22 to 2.80,P=0.004), no significant difference was found when comparing NS to 10 units, and 100 units HPS (10 units: OR=1.51, 95%CI 0.94 to 2.43,P=0.09; 100 units: OR=1.51, 95%CI 0.63 to 3.60,P=0.09). Conclusion HPS appears to be more beneficial than NS, larger rigorously studies are needed for better understanding on the effects of NS and HPS.