  • Diagnosis and Treatment of Spontaneous Rupture of Bronchial Artery Aneurysm in Mediastinum

    Objective To summarize the diagnosis and treatment of spontaneous rupture of bronchial artery aneurysm in mediastinum.Methods Two cases diagnosed as bronchial artery aneurysmby methods of enhanced-CT plus independent post-procedure techniques and bronchial artery selective angiography were cured by different intervention surgeries in our hospital. The clinical data of these two patients and different interventional treatments were summarized.Results Case 1 was a 38-year old male.He was given coils and PVC micro-particles, and bronchial artery selective angiography showed distal vascular occlusion and aneurysmsize decreased. Case 2 was a 59-year old female. She was also given coils, but digital subtraction angiography showed bleeding of bronchial artery whose opening was near to the aorta.Then a stent was implanted in the descending aorta to isolate the bleeding bronchial artery, and bronchial artery selective angiography showed blood flow was completely blocked. Conclusions Enhanced-CT plus vascular three-dimensional reconstruction and bronchial artery selective angiography is a chief method to diagnose bronchial artery aneurysm. Bronchial artery embolization and/ or isolating surgery with covered stent are minimally invasive, efficient, trustworthy treatment for spontaneous rupture of bronchial-artery aneurysmin mediastinum. Different techniques of interventional treatment are selected depending on lesion.

    Release date:2016-09-13 03:50 Export PDF Favorites Scan
  • ENDOVASCULAR TREATMENT OF MIDDLE CEREBRAL ARTERY BIFURCATION ANEURYSMS

    Objective To summarize the diagnosis and endovascular treatment of middle cerebral artery (MCA) bifurcation aneurysm. Methods Between January 2010 and June 2011, 32 patients with MCA bifurcation aneurysm underwent endovascular treatment. There were 12 males and 20 females, aged 49.5 years on average (range, 35-81 years). All patients had sudden headache, 2 cases had disturbance of consciousness and hemi plegia, and 22 cases had a history ofhypertension. Before operation, 10 cases were classified as Hunt-Hess level I, 15 cases as level II, and 7 cases as level III; 24 cases were classified as Fisher level II and 8 cases as level III. The patients underwent coil embolization using single microcatheter in 16 cases, using double microcatheter in 7 cases, using balloon-assisted in 4 cases, using single stent in 4 cases, and using double stent in 1 case. Results The results of postoperative immediate digital subtraction angiography showed that 30 patients achieved dense embolization, and 2 patients using single microcatheter achieved approximated dense embolization. Among them, 18 cases suffered extensive subarachnoid hemorrhage, thus lumbar puncture continued drainage was performed for 3-7 days; the other 14 cases had l ittle subarachnoid hemorrhage, lumbar puncture released hemorrhagic cerebrospinal fluid discontinuously, and after1 week, head CT demonstrated that subarachnoid hemorrhage was significantly decreased. At 1 day after surgery, 2 patients had local cerebral ischemia; after Nimotop and other drugs were used for 1 week, the symptom was alleviative. All 32 patients were followed up 4 to 17 months. No aneurysm rupture and bleed occurred during follow-up; no other complications or sequelae was observed except for 3 cases of hemiparesis and 1 case of aphasia. The computed tomographic angiography examination showed no re-open of dense embolized aneurysm at 3, 6 months, and 1 year after surgery. Conclusion As long as appropriate intervention treatment method is chosen, endovascular treatment of MCA bifurcation aneurysm is safe and effective.

    Release date:2016-08-31 04:23 Export PDF Favorites Scan
  • Simulation design and experimental study of magnetic stimulation coil for robot pigeon

    To explore the feasibility of applying magnetic stimulation technology to the movement control of animal robots, the influence of coil radius, number of turns and other factors on the intensity, depth and focus of magnetic stimulation was simulated and analyzed for robot pigeons. The coil design scheme was proposed. The coil was placed on the head and one of the legs of the pigeon, and the leg electromyography (EMG) was recorded when magnetic stimulation was performed. Results showed that the EMG was significantly strengthened during magnetic stimulation. With the reduction of the output frequency of the magnetic stimulation system, the output current was increased and the EMG was enhanced accordingly. Compared with the brain magnetic stimulation, sciatic nerve stimulation produced a more significant EMG enhancement response. This indicated that the magnetic stimulation system could effectively modulate the functions of brain and peripheral nerves by driving the coil. This study provides theoretical and experimental guidance for the subsequent optimization and improvement of practical coils, and lays a preliminary theoretical and experimental foundation for the implementation of magnetic stimulation motion control of animal robots.

    Release date: Export PDF Favorites Scan