Objective?To discuss the clinical application of total hip arthroplasty (THA) with collum femoris preserving (CFP) prosthesis and to analyze the mid-term effectiveness.?Methods?Between January 2004 and February 2007, 45 patients (48 hips) underwent THA with CFP prosthesis. There were 29 males (31 hips) and 16 females (17 hips) with an average age of 48.8 years (range, 38-60 years), including 20 left hips, 22 right hips, and 3 bilateral hips. The causes of hip replacement were osteoarthritis (20 cases), avascular necrosis of femoral head (13 cases), dysplasia (4 cases), rheumatoid arthritis (3 cases), post-traumatic osteoarthritis (2 cases), ankylosing spondylitis (2 cases), and Perths disease (1 case). The average disease duration was 6.1 years (range, 2-13 years). Harris scores, visual analogue scale (VAS) score, and the hip range of motion (ROM) were recorded at pre- and post-operation. The X-ray films were taken at pre- and post-operation to observe the position, loosening of the prosthesis, and ectopic ossification. The gait of patients were also evaluated during follow-up. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients.?Results?All 45 patients were followed up 5-8 years with an average of 6.4 years. All the incisions healed by first intention. No infection, hip dislocation, nerve injury, or deep vein thrombosis occurred. Six cleavage fractures (13.3%) of the lateral femoral diaphysis at the distal prosthesis occurred during operation, which healed at 8 months postoperatively without any treatment. Mild ectopic ossification occurred in 4 patients (8.9%) who had no discomfort. Five patients (11.1%) had bone mineral density loss in the region of the proximal femur. The survival rates of the cups and stems were all 100% at last follow-up. The results of Harris score, VAS score, and ROM of the hip joint at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P lt; 0.05). No significant difference was found in VAS score and ROM of the hip joint between at 1 year postoperatively and at last follow-up (P gt; 0.05) except the Harris score (P lt; 0.05). According to Harris functional assessment at last follow-up, the results were excellent in 31 hips, good in 11 hips, and fair in 6 hips with an excellent and good rate of 87.5%. The physiological role, body pain, and total health scores were significantly lower than the reference value of urban men from Sichuan province (P lt; 0.05), but no significant difference was found in the other scores of the SF-36 when compared with the reference value (P gt; 0.05).?Conclusion?THA with CFP prosthesis is a good option for the young patient with complete collum femoris and without osteoporosis, and can achieve good mid-term effectiveness.
Objective To evaluate the therapeutic outcome of artificial total hip arthroplasty (THA) with collum femoris preserving for hip joint desease in young and middle-aged patients. Methods From March 2002 to March 2005, 26 cases (31 hips) of hip joint disease were treated with artificial THA with collum femoris preserving, including 19 males (23 hips)and 7 females (8 hips) and aged 32-48 years with an average of 37 years. In 31 hips, 17 left hips and 14 right hips were involved. There were 9 cases of osteoarthritis of the hip joint caused by avascular necrosis of the femoral head (ANFH), 7 cases of ANFH, 3 cases of femoral head necrosis caused by dysplasia of acetabular, 1 case of osteoarthritis of the hip joint caused by ankylosing spondyl itis, and 2 cases of rheumatoid arthritis; the course of disease was 2-11 years (5.6 years on average). Two cases of femoral neck fracture (Garden IV), and 2 cases of non-union femoral neck fractures (1 for Garden III and 1 for Garden IV), the course of disease was 5 days, 24 months, and 26 months. The prime symptoms were pain, difficult walk and l imp. All patients were taken X-ray to exclude osteoporosis. Results The right distal femur prosthesis of a bilateral patient cracked owing to excessive amputation of collum femoris, and fracture healed after symptomatic treatment. All the incisions healed by first intention and no compl ications occurred. All patients were followed up for 4-7 years, with an average of 5.6 years. One case had poor hip function because he did not follow rehabil itation procedure, and the others achieved good outcome with normal gait. One case complained of persistent pain 6 months after operation, and was rel ieved by administration of some non-steroidal antiinflammatory drugs and anti-osteoporosis drugs 6 months later. The X-ray films after operation and at last follow up showed good location of prosthesis and no bone resorption. Harris score at last follow-up was 91.31 ± 0.77, and it was significantly higher than that before operation (50.88 ± 0.90), (P lt; 0.05). The excellent and good rate was 93.5% (excellent in 11 hips, good in 18 hips, and fair in 2 hips). Conclusion Artificial THA with collum femoris preserving can retain more bone, be easier for revision, and has an excellent outcome.